Schneider Electric LC1D18P7, EAN: 3389110349535

Schneider Electric LC1D18P7 Contactor 3p 1S+1O

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D18P7 Contactor 3p 1S+1O

Lieske Part No. 399198
Mfg Part No LC1D18P7
EAN-Code 3389110349535
Manufacturer Schneider Electric
Here only 76,20 EUR
90,68 EUR incl. VAT

Further information for Schneider Electric LC1D18P7 Contactor 3p 1S+1O

Complementary
Motor power kW4 kW at 220/230 V AC 50/60 Hz (AC-3); 7.5 kW at 380/400 V AC 50/60 Hz (AC-3); 9 kW at 415/440 V AC 50/60 Hz (AC-3); 10 kW at 500 V AC 50/60 Hz (AC-3); 10 kW at 660/690 V AC 50/60 Hz (AC-3); 4 kW at 220/230 V AC 50/60 Hz (AC-3e); 7.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 9 kW at 415/440 V AC 50/60 Hz (AC-3e); 10 kW at 500 V AC 50/60 Hz (AC-3e); 10 kW at 660/690 V AC 50/60 Hz (AC-3e); 4 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp1 hp at 115 V AC 50/60 Hz for 1 phase motors; 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit; 32 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 300 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current145 A 40 °C - 10 s for power circuit; 240 A 40 °C - 1 s for power circuit; 40 A 40 °C - 10 min for power circuit; 84 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 50 A gG at
Average impedance2.5 mOhm - Ith 32 A 50 Hz for power circuit
Power dissipation per pole2.5 W AC-1; 0.8 W AC-3; 0.8 W AC-3e
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability1.65 Mcycles 18 A AC-3 at Ue
Control circuit typeAC at 50/60 Hz standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time12...22 ms closing; 4...19 ms opening
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportRail; Plate
Contractual warranty
Warranty (in months)18
Environment
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1
Product certificationsUL; CCC; CSA; Marine; UKCA; EAC; CB Scheme
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor open (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms)
Height77 mm
Width45 mm
Depth86 mm
Net weight0.33 kg
Logistical informations
Country of originFR
Main
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current18 A (at
[Uc] control circuit voltage230 V AC 50/60 Hz
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width9.000 cm
Package 1 Length11.000 cm
Package 1 Weight343.000 g
Unit Type of Package 2S02
Number of Units in Package 220
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight7.150 kg
Unit Type of Package 3P06
Number of Units in Package 3320
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight126.500 kg
The LC1D18P7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for motor control and operation with resistive loads. It is designed for use in industrial plants where reliable and safe switching functions are required for medium power applications. The device has a rated operational current of 18 A at a rated operational voltage of 400 V AC in usage category AC-3, covering a motor power of 7.5 kW. The control circuit voltage is 230 V AC at 50/60 Hz, making it suitable for standard industrial applications. The contact configuration includes 3 closed contacts in the main current circuit, plus additional auxiliary contacts in the configuration of 1 closed + 1 open, which can be used for signaling and control tasks.

Applications

The contactor is designed for various usage categories, including AC-3, AC-3e, AC-1, and AC-4. Category AC-3 refers to operation with three-phase motors under normal load conditions, while AC-3e is intended for operation with three-phase motors under increased load (e.g., in crane applications). Category AC-4 covers applications with high inrush currents, such as those occurring during frequent starting operations or with drives requiring high torque. The rated insulation voltage is 690 V for the circuit, complying with IEC 60947-4-1 standards, allowing the device to be used in installations requiring higher voltage safety. Overvoltage category III and pollution degree 3 indicate suitability for industrial environments with increased stress from voltage surges and contamination.

Functions and Equipment in Detail

The contactor has a mechanical life of 15 million switching cycles and an electrical life of 1.65 million cycles at 18 A AC-3, indicating high reliability and durability. The power loss per pole is 0.8 W at AC-3 and AC-3e, ensuring efficient heat dissipation and low thermal stress. Heat dissipation ranges between 2 and 3 W at 50/60 Hz. The operating time is 12 to 22 ms, enabling fast switching response. The coil is designed without an integrated control module, allowing for simple installation and maintenance. Contacts are equipped with Everlink and spring terminals, ensuring a secure and long-lasting electrical connection. Mechanically interlocked contacts and mirror contacts make the device suitable for safety applications, as they guarantee secure locking of switching states.

Technology Explained Simply

The rated short-time withstand current is 145 A for 10 seconds and 240 A for 1 second for the circuit, demonstrating the contactor’s ability to handle temporary overloads under transient conditions. The rated breaking capacity is 300 A at 440 V, highlighting its capability to safely interrupt short-circuit currents. The rated making capacity is 300 A at 440 V for the circuit, indicating its ability to safely close under load conditions. The rated impulse withstand voltage is 6 kV, ensuring insulation strength against electrical overvoltages. The control circuit voltage limits range from 0.3 to 0.6 Uc for drop-out voltage and from 0.8 to 1.1 Uc for operation, ensuring stable function even with voltage fluctuations. The pickup power is 70 VA at 50/60 Hz, and the holding power consumption is 7 VA at 50 Hz and 7.5 VA at 60 Hz.

Compatibility and Accessories

The contactor is equipped with compatibility code LC1D, enabling the use of suitable accessories such as auxiliary switch blocks (e.g., LAD8N02, LADN22S), time modules (e.g., LA4-DT2U, LADR0), interlocking blocks (e.g., LAD6K10M), and motor protection switches (e.g., GV2P20, GV2L20). These components can be used to extend functionality, introduce time delays, or provide mechanical interlocking in control systems. The safety cover is integrated as standard, supporting compliance with safety regulations during installation and maintenance.

Mounting and Installation

Mounting is done via screw terminals, with device dimensions of 45 mm (width) × 77 mm (height) × 86 mm (depth). The weight is 0.33 kg. Installation is quick and easy, as spring terminals and Everlink technology enable secure connections without additional tools. Certifications according to UL, CSA, GOST, CCC, DNV, RINA, BV, GL, and LROS (Lloyds Register of Shipping) demonstrate international recognition and suitability for various markets and applications, including marine and industrial environments.

Operational Advantages

The contactor offers high operational safety through mechanically interlocked contacts and mirror contacts, enabling secure state monitoring. Long service life and low power loss ensure efficient and low-maintenance operation. Compatibility with various accessories allows flexible adaptation to specific requirements. Certifications and compliance with international standards (IEC 60947, EN/ISO 13849-1) guarantee reliability and safety in industrial use. The operating time of 12 to 22 ms enables fast response in control systems. The integrated safety cover supports compliance with occupational safety regulations during installation and maintenance.

Safety Level

The contactor meets safety level requirements of B10d = 1369863 cycles at rated load and B10d = 20000000 cycles at mechanical load according to EN/ISO 13849-1, confirming its suitability for safety-critical applications. The mechanical life of 15 million cycles and electrical life of 1.65 million cycles underscore the robustness and reliability of the device.

Certifications

The device is certified according to UL, CSA, GOST, CCC, DNV, RINA, BV, GL, and LROS (Lloyds Register of Shipping), confirming international recognition and suitability for various markets and applications, including marine and industrial environments. Product standards comply with IEC 60947-4-1, IEC 60947-1, and EN/ISO 13849-1.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/399198
qrcode für Schneider Electric LC1D18P7 Contactor 3p 1S+1O