| Complementary |
| Motor power kW | 4 kW at 220/230 V AC 50/60 Hz (AC-3); 7.5 kW at 380/400 V AC 50/60 Hz (AC-3); 9 kW at 415/440 V AC 50/60 Hz (AC-3); 10 kW at 500 V AC 50/60 Hz (AC-3); 10 kW at 660/690 V AC 50/60 Hz (AC-3); 4 kW at 220/230 V AC 50/60 Hz (AC-3e); 7.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 9 kW at 415/440 V AC 50/60 Hz (AC-3e); 10 kW at 500 V AC 50/60 Hz (AC-3e); 10 kW at 660/690 V AC 50/60 Hz (AC-3e); 4 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 1 hp at 115 V AC 50/60 Hz for 1 phase motors; 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 32 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 300 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 300 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 145 A 40 °C - 10 s for power circuit; 240 A 40 °C - 1 s for power circuit; 40 A 40 °C - 10 min for power circuit; 84 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 50 A gG at |
| Average impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
| Power dissipation per pole | 2.5 W AC-1; 0.8 W AC-3; 0.8 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 1.65 Mcycles 18 A AC-3 at Ue |
| Control circuit type | AC at 50/60 Hz standard |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 12...22 ms closing; 4...19 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate; Rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1 |
| Product certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor open (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms) |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Net weight | 0.33 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load; Motor control |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 18 A (at |
| [Uc] control circuit voltage | 115 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 8.100 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 357.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.448 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 160 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 67.448 kg |
The LC1D18FE7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for controlling motors and resistive loads. It features a rated operational current of 18 A and is designed for use categories AC-1, AC-3, AC-3e, and AC-4. The control circuit voltage is 115 V AC at 50/60 Hz, making it suitable for use in standard industrial networks. The device is equipped with an additional auxiliary contact configuration consisting of one normally open (NO) and one normally closed (NC) contact, making it suitable for complex control logic. The rated operational power is 7.5 kW at 380/400 V AC (AC-3), enabling the control of medium-sized motors. The coil is designed without an integrated switching module, allowing for flexible adaptation to existing circuits.
Applications
This contactor is primarily designed for motor control in industrial plants, particularly in applications with medium to high loads. It is suitable for controlling three-phase motors in production lines, conveyor systems, and pump systems. Use categories AC-3 and AC-3e cover typical requirements for start-stop operations, while AC-4 is intended for applications with high inrush currents. Certifications according to CCC, UL, GOST, CSA, BV, LROS, DNV, and RINA enable use in international markets, including marine and offshore applications.
Functions and Equipment in Detail
The device features a mechanically interlocked contact arrangement, ensuring safe and reliable switching operations. The contacts are equipped with mirror contacts, enabling monitoring of the switching state and being relevant for safety applications. Current connections are made using Everlink technology with spring terminals, ensuring quick and secure installation. The auxiliary contacts are instantaneous and allow integration into control circuits for signals, such as status indicators or feedback to control devices. The safety cover protects against accidental contact with the contacts and increases operational safety.
Technology Explained Simply
The rated operational voltage for the current circuit is up to 690 V, with insulation strength specified according to IEC 60947-4-1. The rated impulse voltage withstand is 6 kV, ensuring high robustness against transient voltage surges. Overvoltage category III and pollution degree 3 make the device suitable for industrial environments with increased contamination risk. The thermal current rating is 32 A in the current circuit at 60 °C, defining the load capacity under real operating conditions. The electrical life expectancy is 1.65 million switching cycles at 18 A and AC-3 operation, while the mechanical life expectancy is 15 million cycles. The operating time is between 12 and 22 milliseconds, ensuring fast response in the control circuit.
Compatibility and Accessories
The contactor is marked with compatibility designation LC1D, enabling use with a wide range of accessories from the TeSys Deca Advanced series. Compatible components include auxiliary switch blocks such as LAD8N20 or LADN22, interlocking blocks such as LAD6K10F, time modules such as LA4-DT0U, and motor protection relays such as LRD21. Combining with mechanical interlocks such as LAD9V2 or current connectors such as LAD9V5 extends functionality for complex systems.
Mounting and Installation
Mounting is done via standard screw terminals, with Everlink technology ensuring a secure and long-lasting connection. Dimensions are 45 mm (width) × 77 mm (height) × 86 mm (depth), allowing compact placement in enclosures. The weight is 0.33 kg. Installation requires no special tools, as terminals are directly screwed. The control circuit voltage of 115 V AC is standard in many industrial plants, making integration into existing systems straightforward.
Operational Advantages
The contactor offers high reliability due to the mechanical interlocking of contacts and long service life. The low power loss of 0.8 W per pole under AC-3 operation reduces heat generation and lowers the load on the control system. Heat dissipation is 2 to 3 W at 50/60 Hz, easing cooling in the enclosure. Certifications according to international standards ensure use in various markets. The fast operating time of 12 to 22 ms enables responsive control, which is particularly beneficial in automated processes. Compatibility with various accessories allows flexible adaptation to specific requirements.