| Complementary |
| Motor power kW | 4 kW at 220/230 V AC 50/60 Hz (AC-3); 7.5 kW at 380/400 V AC 50/60 Hz (AC-3); 9 kW at 415/440 V AC 50/60 Hz (AC-3); 10 kW at 500 V AC 50/60 Hz (AC-3); 10 kW at 660/690 V AC 50/60 Hz (AC-3); 4 kW at 220/230 V AC 50/60 Hz (AC-3e); 7.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 9 kW at 415/440 V AC 50/60 Hz (AC-3e); 10 kW at 500 V AC 50/60 Hz (AC-3e); 10 kW at 660/690 V AC 50/60 Hz (AC-3e); 4 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 1 hp at 115 V AC 50/60 Hz for 1 phase motors; 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit; 32 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 300 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 300 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 145 A 40 °C - 10 s for power circuit; 240 A 40 °C - 1 s for power circuit; 40 A 40 °C - 10 min for power circuit; 84 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 50 A gG at |
| Average impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
| Power dissipation per pole | 2.5 W AC-1; 0.8 W AC-3; 0.8 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 1.65 Mcycles 18 A AC-3 at Ue |
| Control circuit type | AC at 50/60 Hz standard |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 12...22 ms closing; 4...19 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1 |
| Product certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor open (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms) |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Net weight | 0.33 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load; Motor control |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 18 A (at |
| [Uc] control circuit voltage | 48 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 9.500 cm |
| Package 1 Length | 12.000 cm |
| Package 1 Weight | 365.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.218 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 160 |
| Package 3 Height | 45.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 67.552 kg |
The LC1D18E7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor drives and resistive loads. It features a rated operational current of 18 A at a control circuit voltage of 48 V AC and is designed for usage categories AC-1, AC-3, AC-3e, and AC-4. The primary application is motor control, covering a motor power of 7.5 kW at 400 V AC and category AC-3. The device is equipped with additional auxiliary contacts comprising 1 normally open (NO) and 1 normally closed (NC) contact, making it suitable for complex control applications.
Applications
This contactor is designed for industrial applications requiring reliable and safe switching functions. It is particularly suitable for controlling three-phase motors in production plants, conveyor systems, pumps, and fans. Usage categories AC-3 and AC-4 allow operation under frequent switching conditions and high mechanical stress, such as during motor start-up and braking. Certifications according to UL, CSA, GL, RINA, DNV, BV, GOST, LROS, and CCC confirm suitability for international applications, including marine and heavy industrial environments.
Functions and Equipment in Detail
The LC1D18E7 contactor features coil technology without an integrated control module, enabling flexible adaptation to various control circuits. The control circuit voltage is 48 V AC at 50/60 Hz. The auxiliary contacts are non-delayed and allow integration into control logic, e.g., for status indication or feedback to a higher-level control system. The mechanical life expectancy is 15 million switching cycles, while the electrical life expectancy at 18 A and AC-3 operation is 1.65 million cycles. The operating time ranges from 12 to 22 milliseconds, ensuring fast switching response.
Technology Explained Simply
Current connections are made using Everlink technology with spring terminals, ensuring secure and long-lasting connections. The rated insulation voltage is 690 V for the power circuit and complies with standards IEC 60947-4-1 as well as UL and CSA. The overvoltage category III and pollution degree 3 make the device suitable for environments with increased electrical stress and contamination risk. The rated impulse withstand voltage is 6 kV, ensuring robustness against transient voltage surges. Power dissipation is 2 to 3 W at 50/60 Hz, enabling efficient cooling in enclosed switchgear.
Compatibility and Accessories
The contactor is compatible with various accessory modules that extend its functionality. These include time modules such as LA4-DT2U for delays from 1.5 to 30 seconds, control modules such as LAD4RCE and LAD4RCG for RC elements, and auxiliary switch blocks such as LADN40 (4 NO) or LADN11 (1 NO + 1 NC). For special applications, delayed auxiliary switch blocks such as LAD-R4 (delayed release) or LAD-S2 (delayed pickup) are available. Additionally, interface modules such as LA4-DFB and LA4-DWB, as well as main current connectors such as LAD9V5 and LAD9V6, are available. The protective cover LAD9ET1S provides additional protection for the front of the device.
Mounting and Installation
Mounting is done on standard rails (DIN rail) and is simplified by the compact design with dimensions of 45 mm (width) × 77 mm (height) × 86 mm (depth). Spring terminals enable quick and secure connection of wires. Installation requires no special tools, as connections are made via screw terminals. The safety cover is integrated as standard, facilitating compliance with safety regulations.
Operational Advantages
The contactor offers high operational safety through mechanically coupled contacts and mirror contacts, ensuring reliable switching even under high loads. The rated breaking capacity is 300 A at 440 V, increasing reliability during short-circuit events. The rated making capacity is 300 A for the power circuit, confirming the ability to perform safe switching under load. Power loss per pole is 2.5 W at AC-1 and 0.8 W at AC-3 and AC-3e, ensuring efficient energy use. Certification according to EN/ISO 13849-1 with a safety level B10d of 1,369,863 cycles at rated load makes the device suitable for safety applications.