Schneider Electric LC1D18ABD, EAN: 3606487539421

Schneider Electric LC1D18ABD Contactor 3p+1S+1Ö 18A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D18ABD Contactor 3p+1S+1Ö 18A

Lieske Part No. 157076
Mfg Part No LC1D18ABD
EAN-Code 3606487539421
Manufacturer Schneider Electric
Here only 149,36 EUR
177,74 EUR incl. VAT

Further information for Schneider Electric LC1D18ABD Contactor 3p+1S+1Ö 18A

Complementary
Motor power kW4 kW at 220...230 V AC 50/60 Hz (AC-3); 7.5 kW at 380...400 V AC 50/60 Hz (AC-3); 9 kW at 415...440 V AC 50/60 Hz (AC-3); 10 kW at 500 V AC 50/60 Hz (AC-3); 10 kW at 660...690 V AC 50/60 Hz (AC-3); 4 kW at 400 V AC 50/60 Hz (AC-4); 4 kW at 220...230 V AC 50/60 Hz (AC-3e); 7.5 kW at 380...400 V AC 50/60 Hz (AC-3e); 9 kW at 415...440 V AC 50/60 Hz (AC-3e); 10 kW at 500 V AC 50/60 Hz (AC-3e); 10 kW at 660...690 V AC 50/60 Hz (AC-3e)
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current32 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signalling circuit
Irms rated making capacity300 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current40 A 40 °C - 10 min for power circuit; 84 A 40 °C - 1 min for power circuit; 145 A 40 °C - 10 s for power circuit; 240 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 50 A gG at
Average impedance2.5 mOhm - Ith 32 A 50 Hz for power circuit
Power dissipation per pole0.8 W AC-3; 0.8 W AC-3e; 2.5 W AC-1
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability30 Mcycles
Electrical durability1.65 Mcycles 18 A AC-3 at Ue
Control circuit typeDC standard
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.1...0.25 Uc (-40…70 °C):drop-out DC 50/60 Hz; 0.7...1.25 Uc (-40…60 °C):operational DC 50 Hz; 1...1.25 Uc (60…70 °C):operational DC 60 Hz
Inrush power in W5.4 W (at 20 °C)
Hold-in power consumption in W5.4 W at 20 °C
Operating time63 ±15 % ms closing; 20 ±20 % ms opening
Time constant28 ms
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportPlate; Rail
Contractual warranty
Warranty (in months)18
Environment
StandardsEN 60947-4-1; IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certificationsCB Scheme; CCC; cULus; CE; UKCA; EU-RO-MR by DNV
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms)
Height110 mm
Width45 mm
Depth101 mm
Net weight624 g
Logistical informations
Country of originFR
Main
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationMotor control; Resistive load
Utilisation categoryAC-1; AC-3; AC-3e; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current18 A (at
[Uc] control circuit voltage24 V DC
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width10.500 cm
Package 1 Length11.500 cm
Package 1 Weight644.000 g
Unit Type of Package 2S02
Number of Units in Package 215
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.936 kg
Unit Type of Package 3P06
Number of Units in Package 3240
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight168.100 kg
The LC1D18ABD contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for motor control and operation of resistive loads. It is designed for use in industrial plants where reliable and safe switching performance is required for medium power applications. The device has a rated operational current of 18 A and is designed for a control circuit voltage of 24 V DC. The rated operational power is 7.5 kW at 400 V AC in usage category AC-3, making it suitable for driving electric motors in typical industrial applications.

Applications

The contactor is intended for various usage categories, including AC-1 (resistive load), AC-3 (motor starting and stopping), and AC-4 (frequent starting and stopping). Category AC-3e is also supported, enabling application in special motor drives with higher switching frequency requirements. The maximum motor power is 10 kW at 660–690 V AC, with the exact power depending on the operating voltage. Applications include controlling electric motors and switching resistive loads in industrial and mechanical systems.

Functions and Equipment in Detail

The device features three main contacts (3P) and integrated auxiliary contacts configured as 1 NO + 1 NC. These auxiliary contacts are mechanically linked and comply with IEC 60947-5-1. Additionally, mirror contacts are included, suitable for safety applications and enabling redundant switching functionality. The contacts are equipped with SnapIN connection terminals, ensuring fast, secure, and maintenance-free electrical connections. The integrated bidirectional peak-limiting diode suppressor protects the coil from voltage surges and increases the device’s lifespan.

Technology Explained Simply

The contactor coil operates at 24 V DC and has an inrush power of 5.4 W at 20 °C. The holding power consumption is also 5.4 W. The operating time is 63 ±15 % ms for closing and 20 ±20 % ms for opening. The time constant is 28 ms. The maximum operating rate is 3600 switching operations per hour at 60 °C. The rated insulation voltage is 690 V for both the power circuit and signal circuit, ensuring high electrical safety. Overvoltage category III and pollution degree 3 indicate suitability for industrial environments with increased stress.

Compatibility and Accessories

The contactor is compatible with various accessories, including delayed auxiliary switch blocks (e.g. LAD-R4, LADT0, LADT2), motor protection relays (e.g. LRD21, GV2ME20A), and auxiliary switch blocks with different contact configurations (e.g. LADN02A, LADN11A). These components can be used to extend functionality, introduce time delays, or integrate into safety circuits. The LAD9V2 interlock enables mechanical interlocking for TeSys D contactors.

Mounting and Installation

Mounting is done via SnapIN connection terminals, which allow for easy and secure wiring connections. The device dimensions are 45 mm (width) × 110 mm (height) × 95 mm (depth). Installation requires no additional tools, as the terminals connect by simple snapping. The coil is designed for operating voltages of 0.7 to 1.25 Uc at -40…60 °C, with operation up to 1.25 Uc possible at 60…70 °C.

Operational Advantages

The contactor offers a high mechanical life of 30 million switching cycles and an electrical life of 1.65 million switching cycles at 18 A AC-3. The integrated coil protection with bidirectional diode suppression reduces stress from voltage surges. Mechanically coupled auxiliary contacts and mirror contacts enhance reliability in safety applications. The use of SnapIN terminals reduces installation time and increases safety through secure connections without additional tools. The rated impulse withstand voltage of 6 kV ensures high electrical stability under transient voltage conditions.

Important Technical Specifications

  • Rated operational current (Ie): 18 A
  • Control circuit voltage (Uc): 24 V DC
  • Rated operational power (AC-3, 400 V): 7.5 kW
  • Auxiliary contacts: 1 NO + 1 NC
  • Life expectancy: 30 million mechanical switching cycles, 1.65 million electrical switching cycles (AC-3)
  • Insulation resistance: > 10 MΩ (signal circuit)
  • Rated insulation voltage: 690 V (power and signal circuits)
  • Overvoltage category: III
  • Pollution degree: 3
  • Coil protection: integrated bidirectional peak-limiting diode suppressor
  • Mounting: SnapIN connection terminals
  • Compatibility: accessories such as LAD-R4, LADT0, LADT2, LRD21, GV2ME20A, LADN series, LAD9V2