| Additional features |
| Motor power HP (UL / CSA standards) | 40 hp at 200/208 V AC 50/60 Hz for 3-phase motors; 50 hp at 230/240 V AC 50/60 Hz for 3-phase motors; 100 hp at 460/480 V AC 50/60 Hz for 3-phase motors; 125 hp at 575/600 V AC 50/60 Hz for 3-phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 S |
| Safety cover | With |
| [Ith] conventional thermal current in free air | 200 A (at 60 °C) for circuit |
| [Irms] Rated making capacity | 140 A AC for signal circuits conforming to IEC 60947-5-1; 250 A DC for signal circuits conforming to IEC 60947-5-1; 1660 A at 440 V for power circuits conforming to IEC 60947 |
| Rated breaking capacity | 1400 A at 440 V for circuit corresponds to IEC 60947 |
| [Icw] rated short-time current withstand | 250 A 40 °C - 10 min for circuit; 580 A 40 °C - 1 min for circuit; 1200 A 40 °C - 10 s for circuit; 1400 A 40 °C - 1 s for circuit; 100 A - 1 s for signal circuit; 120 A - 500 ms for signal circuit; 140 A - 100 ms for signal circuit |
| Associated fuse | 10 A gG for signal circuit, compliant with IEC 60947-5-1; 315 A gG at |
| Average impedance | 0.6 MΩ - Ith 200 A 50 Hz for circuit |
| Power dissipation per pole | 24 W AC-1; 13,5 W AC-3; 13,5 W AC-3e |
| [Ui] Rated insulation voltage | Circuit: 600 V CSA certified; Circuit: 600 V UL certified; Circuit: 1000 V complies with IEC 60947-4-1; Signal circuit: 690 V complies with IEC 60947-1; Signal circuit: 600 V CSA certified; Signal circuit: 600 V UL certified |
| Over voltage category | III |
| Pollution degree | 3 |
| [Uimp] Rated impulse voltage withstand | 8 kV corresponds to IEC 60947 |
| Security level rating | B10d = 684932 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 8 Mcycles |
| Electrical lifetime | 0.85 Mcycles 150 A AC-3 at Ue |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Integrated bidirectional transient voltage suppressor diodes |
| Control circuit voltage limits | 0.3 - 0.5 Uc (-40…70 °C): drop-out voltage AC 50/60 Hz; 0.8 - 1.15 Uc (-40…55 °C): operation AC 50/60 Hz; 1 - 1.15 Uc (55…70 °C): operation AC 50/60 Hz |
| Input power in VA | 280…350 VA 60 Hz cos phi 0.9 (at 20 °C); 280…350 VA 50 Hz cos phi 0.9 (at 20 °C) |
| Hold power consumption in VA | 2…18 VA 60 Hz cos phi 0.9 (at 20 °C); 2…18 VA 50 Hz cos phi 0.9 (at 20 °C) |
| Heat emission | 3…4,5 W at 50/60 Hz |
| Operating time | 20 - 35 ms closing; 40 - 75 ms opening |
| Maximum operating rate | 1200 cyc/h at 60 °C |
| Connections - terminals | Control circuit: ring terminal lugs - outer diameter: 8 mm; Current circuit: ring terminal lugs - outer diameter: 25 mm; Current circuit: rails 1 - rail cross-section: 5 x 25 mm |
| Tightening moment | Control circuit: 1.2 Nm - on ring terminal lugs - with flat screwdriver Ø 6 M3.5; control circuit: 1.2 Nm - on ring terminal lugs - with Phillips screwdriver No. 2 M3.5; power circuit: 12 Nm - on ring terminal lugs hexagonal screw head 13 mm M8; power circuit: 12 Nm - on rails hexagonal screw head 13 mm M8; control circuit: 1.2 Nm - on ring terminal lugs - with screwdriver position No. 2 M3.5 |
| Configuration of auxiliary contacts | 1 S + 1 Ö |
| Type of auxiliary contacts | Mechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1 |
| Signalling angular frequency | 25 - 400 Hz |
| Min. switching voltage | 17 V for signal circuit |
| Min. switching current | 5 mA for signal circuit |
| Insulation resistance | > 10 MΩ for signal circuits |
| Non-overlapping time | 1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact |
| Mounting bracket | Plate; rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys |
| Product or component type | Contactor |
| Device short name | LC1D |
| Application of contactor | Motor control; resistive load |
| Application category | AC-3; AC-3e; AC-1; AC-4 |
| Pole description | 3P |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 200 A (at |
| [Uc] control circuit voltage | 100 V AC 50/60 Hz |
| Mounting |
| Standards | CSA C22.2 No. 14; EN 60947-4-1; IEC 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; UL 60947-4-1; CSA C22.2 No. 60947-4-1; JIS C8201-4-1 |
| Product certifications | UL; CCC; CSA; CE; UKCA; Marine; EAC |
| Degree of protection (IP) | IP20 front side corresponds to IEC 60529 |
| Protection treatment | TH corresponds to IEC 60068-2-30 |
| Climate resistance | complies with IACS E10 damp heat exposure |
| Device ambient temperature | -40…60 °C; 60…70 °C with power reduction |
| Operating altitude | 0 - 3.000 m |
| Fire-resistance | 850 °C corresponds to IEC 60695-2-1 |
| Flame retardancy | V1 corresponds to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5 - 300 Hz); Vibrations contactor closed (4 Gn, 5 - 300 Hz); Shocks contactor closed (15 Gn for 11 ms); Shocks contactor open (6 Gn for 11 ms) |
| Height | 158 mm |
| Width | 120 mm |
| Depth | 136 mm |
| Product weight | 2,5 kg |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 19,0 cm |
| VPE 1 width | 17,0 cm |
| VPE 1 length | 20,5 cm |
| Packaging weight (Lbs) | 2,145 kg |
| VPE 2 type | S06 |
| VPE 2 quantity | 27 |
| VPE 2 height | 73,5 cm |
| VPE 2 width | 60,0 cm |
| VPE 2 length | 80,0 cm |
| VPE 2 weight | 70,915 kg |
The LC1D1506K7 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for motor control and operation with resistive loads. It is designed for use categories AC-1, AC-3, AC-3e, and AC-4, with category AC-3 representing the typical application for driving three-phase motors. The device features a main contact configuration of 3 closers (3S) in the power circuit and integrated auxiliary contacts with 1 closer and 1 opener (1S+1O), which can be used for control and monitoring tasks in plant operation. The rated operational power is 75 kW at 400 V, and the rated operational current Ie is 150 A for category AC-3. The control circuit voltage is 100 V AC at 50/60 Hz, with the coil protected by integrated bidirectional surge-limiting diode suppressors to limit voltage spikes during switching-off operations.
Applications
The contactor is designed for use in industrial plants, particularly for controlling three-phase motors in drive technology, conveyor systems, pumps, and fans. The use category AC-3e allows operation under increased mechanical stress requirements, for example, with frequent starting and stopping. Category AC-4 is suitable for applications with high inrush currents, such as crane drives or lifting equipment. The integrated auxiliary contacts enable use in control circuits, for example, for feedback of switching states to control devices or for actuating warning lights.
Functions and Equipment in Detail
The device features a safety cover that ensures mechanical isolation of the contacts, supporting compliance with safety requirements in critical applications. The contacts are mechanically coupled and equipped with mirror contacts, ensuring high reliability for safety functions. The power circuit terminals are designed as ring cable lug terminals with an outer diameter of 25 mm, enabling a secure and long-lasting connection. The control circuit terminals are also ring cable lug terminals with an outer diameter of 8 mm. The connection terminals are equipped with Everlink technology and spring terminals, enabling quick and easy installation and a stable connection even under vibration.
Technology Explained Simply
The integrated bidirectional surge-limiting diode suppression protects the coil from transient voltage spikes that may occur when the power circuit is suddenly switched off. This extends the coil’s lifespan and reduces interference in the control circuit. The rated impulse voltage withstand is 8 kV, ensuring high insulation strength against transient overvoltages. Overvoltage category III and pollution degree 3 meet the requirements for industrial environments with increased contamination risk. The rated insulation voltage is 1000 V for the power circuit according to IEC 60947-4-1 and 690 V for the signal circuit according to IEC 60947-1. The rated breaking capacity is 1400 A at 440 V, demonstrating the contactor’s ability to safely interrupt short-circuit currents in the plant.
Compatibility and Accessories
The contactor is compatible with various accessories that extend its functionality. These include auxiliary switch blocks such as the LADN046 (4O un-delayed front-mounted) or LADN316 (3S1O un-plated front-mounted), which provide additional contacts for control and monitoring tasks. Time delay blocks such as the LADT26 (1S1O delayed pickup) or LADT46 (1S1O delayed release) allow for setting delay times. Motor protection relays such as the LR9D5369 (90–150 A, Class 10) can be integrated into protection systems. Interface modules such as the LA4-DFB enable connection to digital control systems.
Mounting and Installation
Mounting is done via rail connection with a cross-section of 5 x 25 mm. The terminals are designed for ring cable lugs, with power circuit terminals having an outer diameter of 25 mm and control circuit terminals an outer diameter of 8 mm. The tightening torques are 12 Nm for power circuit terminals (M8 hex) and 1.2 Nm for control circuit terminals (M3.5). The maximum operating rate is 1200 switching cycles per hour at 60 °C, enabling high load capacity in continuously operated plants. The operating time is 20–35 ms for closing and 40–75 ms for opening.
Operational Advantages
The contactor offers a high mechanical life of 8 million switching cycles and an electrical life of 0.85 million switching cycles at 150 A AC-3. The power loss per pole is 24 W at AC-1 and 13.5 W at AC-3 and AC-3e, ensuring efficient heat dissipation and low energy losses. The heat dissipation is between 3 and 4.5 W at 50/60 Hz. The conventional thermal current rating is 200 A at 60 °C in free air. Certifications according to CCC, CSA, RINA, UL, GOST, LROS, BV, GL, and DNV ensure compliance with international safety and quality standards. The rated insulation voltage of 1000 V for the power circuit and 690 V for the signal circuit, along with overvoltage category III, make the device suitable for demanding industrial environments. The integrated bidirectional surge-limiting diode suppression protects the coil and reduces interference in the control circuit. The mechanically coupled contacts and mirror contacts increase reliability in safety applications. The quick and easy setup via Everlink technology and spring terminals reduces installation time and increases operational safety.