| Complementary |
| Motor power kW | 40 kW at 220/230 V AC 50/60 Hz (AC-3); 75 kW at 380/400 V AC 50/60 Hz (AC-3); 80 kW at 415/440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 660/690 V AC 50/60 Hz (AC-3); 75 kW at 1000 V AC 50/60 Hz (AC-3); 40 kW at 220/230 V AC 50/60 Hz (AC-3e); 75 kW at 380/400 V AC 50/60 Hz (AC-3e); 80 kW at 415/440 V AC 50/60 Hz (AC-3e); 90 kW at 500 V AC 50/60 Hz (AC-3e); 100 kW at 660/690 V AC 50/60 Hz (AC-3e); 75 kW at 1000 V AC 50/60 Hz (AC-3e); 22 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 1660 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 1400 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 250 A 40 °C - 10 min for power circuit; 580 A 40 °C - 1 min for power circuit; 1200 A 40 °C - 10 s for power circuit; 1400 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 315 A gG at |
| Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole | 24 W AC-1; 13.5 W AC-3; 13.5 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| Electrical durability | 0.85 Mcycles 150 A AC-3 at Ue |
| Control circuit type | DC standard |
| Coil technology | With integral suppression device |
| Control circuit voltage limits | 0.75...1.2 Uc (-40…55 °C):operational DC; 0.15...0.4 Uc (-40…70 °C):drop-out DC; 1...1.2 Uc (55…70 °C):operational DC |
| Inrush power in W | 270…365 W (at 20 °C) |
| Hold-in power consumption in W | 2.4…5.1 W at 20 °C |
| Operating time | 20...35 ms closing; 40...75 ms opening |
| Time constant | 25 ms |
| Maximum operating rate | 1200 cyc/h at 60 °C |
| Connections - terminals | Control circuit: lugs-ring terminals - external diameter: 8 mm; Power circuit: lugs-ring terminals - external diameter: 25 mm; Power circuit: bars 1 - busbar cross section: 5 x 25 mm |
| Tightening torque | Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5; Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5; Power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8; Power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8; Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; IEC 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1 |
| Product certifications | UL; CCC; CSA; CE; UKCA; Marine; EAC |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (6 Gn for 11 ms) |
| Height | 158 mm |
| Width | 120 mm |
| Depth | 136 mm |
| Net weight | 2.5 kg |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 200 A (at |
| [Uc] control circuit voltage | 24 V DC |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 19.000 cm |
| Package 1 Width | 17.500 cm |
| Package 1 Length | 21.500 cm |
| Package 1 Weight | 2.207 kg |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 27 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 71.212 kg |
The LC1D1506BD contactor from the TeSys series by Schneider Electric is a 3-pole contactor for motor control and control of resistive loads. It features an integrated suppression unit in the coil, which stabilizes switching operations in the control circuit and prevents unwanted voltage spikes. The control circuit voltage is 24 V DC, with operating voltage ranges specified as 0.75 to 1.2 times nominal voltage at temperatures from -40 to 55 °C, and 1 to 1.2 times nominal voltage at 55 to 70 °C. The drop-out voltage is between 0.15 and 0.4 times nominal voltage at -40 to 70 °C. The coil is designed for use in DC standard control circuits.
Applications
This contactor is designed for controlling motors and resistive loads. It covers usage categories AC-3, AC-3e, AC-1, and AC-4, with AC-3 being the typical category for motor drives. The rated operational power is 75 kW at AC-3 and 400 V, with the rated operational current Ie being 150 A at AC-3 and 400 V. Motor power ratings according to UL/CSA standards include 40 hp at 200/208 V AC, 50 hp at 230/240 V AC, 100 hp at 460/480 V AC, and 125 hp at 575/600 V AC, all for 3-phase motors. The rated operating voltage for the circuit is not explicitly specified, but the rated insulation voltage for the circuit is 1000 V according to IEC 60947-4-1, 600 V CSA-certified, and 600 V UL-certified. The overvoltage category is III, the pollution degree is 3, and the rated impulse withstand voltage is 8 kV according to IEC 60947.
Functions and Features in Detail
The device features 3 normally closed contacts in the main circuit (3P) and an additional auxiliary contact block with 1 normally closed and 1 normally open contact. The auxiliary contacts are non-delayed and allow integration into control and monitoring systems. The main circuit terminals are ring terminal lugs with an outer diameter of 25 mm, and they also support mounting of bars with a cross-section of 5 x 25 mm. The control circuit terminals are also ring terminal lugs with an outer diameter of 8 mm. The tightening torques are 12 Nm for the main circuit terminals (hexagonal screw head 13 mm, M8) and 1.2 Nm for the control circuit terminals (flat screwdriver Ø 6 M3.5 or Phillips No. 2 M3.5). The tightening torques are designed for secure and long-lasting connections.
Technology Explained Simply
The integrated suppression unit in the coil reduces magnetic overvoltages during switching off, increasing the coil's lifespan and the reliability of the switching operation. The mechanical life is 8 million switching cycles, and the electrical life at 150 A and AC-3 operation is 0.85 million switching cycles. The power loss per pole is 24 W at AC-1, 13.5 W at AC-3, and 13.5 W at AC-3e. The maximum operating rate is 1200 switching operations per hour at 60 °C. The operating time is 20 to 35 ms for closing and 40 to 75 ms for opening. The time constant is 25 ms. The rated breaking capacity is 1400 A at 440 V for the circuit according to IEC 60947. The rated short-time withstand current is 1400 A for 1 second in the circuit. The associated fuse for the signal circuit is 10 A gG according to IEC 60947-5-1.
Compatibility and Accessories
The contactor is compatible with various auxiliary contact blocks, including LADN136 (1S3O), LADN206 (2S), LAD8N026 (2O), LAD8N116 (1S+1O), LADN026 (2O), LADN116 (1S1O), LADN406 (4S), LADN226 (2S2O), LADN046 (4O), LADN316 (3S1O), LAD8N206 (2S), LADR26 (1S1O latching), LADT46 (1S1O delayed pickup 10), LADT26 (1S1O delayed release 0), LADR06 (1S1O latching). Additionally, time blocks such as LADS26 (1S1O delayed pickup 1) and protection circuits such as the diode LA4DB3B are available. As an alternative, the power contactor LC1D150A6BNE (TeSys Deca LC1D 3p +1S+1O 75 kW 150 A) is offered.
Mounting and Installation
Mounting is done via the designated terminals and screw connections. The main circuit terminals are designed for ring terminal lugs with an outer diameter of 25 mm, and bars with a cross-section of 5 x 25 mm can also be mounted. The control circuit terminals are designed for ring terminal lugs with an outer diameter of 8 mm. The tightening torques are clearly defined to ensure a secure connection. Setup is quick and easy, with the use of Everlink and spring terminals enabling long-lasting current connections.
Operational Advantages
The contactor offers high reliability through mechanically coupled contacts and mirror contacts, making it suitable for safety applications. The integrated suppression unit ensures a stable switching operation. Certifications according to GL, CSA, CCC, UL, DNV, LROS (Lloyds Register of Shipping), RINA, BV, and GOST confirm compliance with international standards. The rated insulation voltage of 1000 V (IEC 60947-4-1) and the impulse withstand voltage of 8 kV (IEC 60947) ensure a safe operating environment. The mechanical life of 8 million cycles and the electrical life of 0.85 million cycles at 150 A AC-3 highlight the durability of the device. The maximum operating rate of 1200 switching operations per hour at 60 °C demonstrates the high load capacity of the contactor.
Safety Level and Standards
The contactor meets the requirements of standard EN/ISO 13849-1 with a safety level B10d of 684932 cycles at rated load and 10000000 cycles at mechanical load. The overvoltage category III and pollution degree 3 indicate a robust construction suitable for demanding environments. Certifications according to UL, CSA, CCC, GL, DNV, LROS, RINA, BV, and GOST confirm international acceptance and use in various industries, including shipping and industrial automation.