| Complementary |
| Motor power kW | 3 kW at 220/230 V AC 50/60 Hz (AC-3); 5.5 kW at 380/400 V AC 50/60 Hz (AC-3); 5.5 kW at 415/440 V AC 50/60 Hz (AC-3); 7.5 kW at 500 V AC 50/60 Hz (AC-3); 7.5 kW at 660/690 V AC 50/60 Hz (AC-3); 3 kW at 220/230 V AC 50/60 Hz (AC-3e); 5.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 5.5 kW at 415/440 V AC 50/60 Hz (AC-3e); 7.5 kW at 500 V AC 50/60 Hz (AC-3e); 7.5 kW at 660/690 V AC 50/60 Hz (AC-3e); 3.7 kW at 400 V AC 50/60 Hz (AC-4) |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) for control circuit; 25 A (at 60 °C) for power circuit |
| Irms rated making capacity | 140 A AC for control circuit conforming to IEC 60947-5-1; 250 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 250 kA at 440 V for power circuit conforming to IEC 60947 |
| Associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1; 25 A at |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole | 0.36 W AC-3; 1.56 W AC-1; 0.36 W AC-3e |
| [Ui] rated insulation voltage | Control circuit: 600 V CSA certified; Control circuit: 600 V UL certified; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Control circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 690 V conforming to IEC 60947-4-1 |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.3...0.6 Uc (60 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (60 °C):operational AC 50 Hz; 0.85...1.1 Uc (60 °C):operational AC 60 Hz |
| Inrush power in VA | 70 VA cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7 VA 50/60 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz for control circuit |
| Operating time | 4...19 ms opening; 12...22 ms closing |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening torque | Control circuit: 1.7 N.m - with screwdriver flat Ø 6 mm; Control circuit: 1.7 N.m - with screwdriver Philips No 2; Power circuit: 1.7 N.m - with screwdriver flat Ø 6 mm; Power circuit: 1.7 N.m - with screwdriver Philips No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contacts; 1.5 ms on energisation between NC and NO contacts |
| Mounting support | Plate; Rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-5-1; CSA C22.2 No 14; EN/IEC 60947-4-1; UL 60947-4-1; IEC 60335-1 |
| Product certifications | GOST; DNV; LROS (Lloyds register of shipping); UL; CCC; BV; RINA; CSA; GL; UKCA |
| IP degree of protection | IP2X conforming to IEC 60529; IP2X conforming to VDE 0106 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -5…60 °C; -40…70 °C at Uc |
| Operating altitude | 3000 m without derating |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Shocks contactor opened (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms) ; Vibrations contactor opened (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Net weight | 3.25 kg |
| Quantity per set | Set of 10 |
| Main |
| Range | TeSys; TeSys Deca |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 25 A (at |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.500 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 8.500 cm |
| Package 1 Weight | 332.500 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.381 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 139.568 kg |
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 5.5 kW, rated operating current Ie at AC-3, 400 V 12 A, coil 230 V AC. Dimensions (WxHxD) 45x77x86 mm, weight 3.25 kg. Category AC-1, AC-3. without built-in amplitude limiter diode. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications due to mechanically coupled contacts and mirror contacts. Certifications according to GOST, DNV, LROS (Lloyds register of shipping), UL, CCC, BV, RINA, CSA, GL. Product standards according to EN/IEC 60947-5-1, CSA C22.2 No 14, EN/IEC 60947-4-1, UL 508.