| Complementary |
| Motor power kW | 3 kW at 220...230 V AC 50/60 Hz (AC-3); 5.5 kW at 380...400 V AC 50/60 Hz (AC-3); 5.5 kW at 415...440 V AC 50/60 Hz (AC-3); 7.5 kW at 500 V AC 50/60 Hz (AC-3); 7.5 kW at 660...690 V AC 50/60 Hz (AC-3); 3.7 kW at 400 V AC 50/60 Hz (AC-4); 3 kW at 220...230 V AC 50/60 Hz (AC-3e); 5.5 kW at 380...400 V AC 50/60 Hz (AC-3e); 5.5 kW at 415...440 V AC 50/60 Hz (AC-3e); 7.5 kW at 500 V AC 50/60 Hz (AC-3e); 7.5 kW at 660...690 V AC 50/60 Hz (AC-3e) |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 25 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signalling circuit |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 40 A gG at |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole | 0.36 W AC-3; 0.36 W AC-3e; 1.56 W AC-1 |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 2 Mcycles 12 A AC-3 at Ue |
| Control circuit type | AC at 50/60 Hz standard |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 12...22 ms closing; 4...19 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate; Rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN 60947-4-1; IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CCC; cULus; CE; UKCA; EU-RO-MR by DNV |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (10 Gn for 11 ms) |
| Height | 107 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Net weight | 387 g |
| Main |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-1; AC-3; AC-3e; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 12 A (at |
| [Uc] control circuit voltage | 48 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.200 cm |
| Package 1 Width | 9.800 cm |
| Package 1 Length | 11.500 cm |
| Package 1 Weight | 413.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 15 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.468 kg |
The LC1D12AE7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for motor control and operation of ohmic loads. It is designed for usage categories AC-1, AC-3, AC-3e, and AC-4 and features a rated operational current of 12 A. The control circuit voltage is 48 V AC at 50/60 Hz. The device is equipped with a protective cover and includes additional auxiliary contacts in the configuration of 1 normally closed + 1 normally open. The auxiliary contacts are mechanically linked and comply with IEC 60947-5-1, with the normally open contact designed as a mirror contact and conforming to IEC 60947-4-1. This construction makes the contactor suitable for safety applications, as mechanical coupling and mirror contacts ensure secure signal transmission.
Applications
The contactor is primarily designed for controlling electric motors, especially in industrial plants. At an operating voltage of 400 V AC and usage category AC-3, the rated operational power is 5.5 kW. It can also be used at other voltages, with motor power varying accordingly: 3 kW at 220–230 V AC (AC-3), 7.5 kW at 500 V AC (AC-3), and 7.5 kW at 660–690 V AC (AC-3). The AC-4 category allows operation at 3.7 kW at 400 V AC. The AC-3e category covers similar power ratings, with values for 400 V AC also being 5.5 kW. The device is thus flexibly applicable in various industrial environments with different voltage conditions.
Functions and Equipment in Detail
The contactor features 3 normally closed contacts in the main current circuit and integrated auxiliary contacts (1 S + 1 Oe). The auxiliary contacts are mechanically linked, ensuring a secure and synchronized switching function. The coil is rated for 48 V AC and operates at frequencies of 50/60 Hz. The operating time is 12–22 ms for closing and 4–19 ms for opening. The maximum operating rate is 3600 switching cycles per hour at an ambient temperature of 60 °C. The heat dissipation is 2–3 W at 50/60 Hz. The pickup power is 70 VA at 50 Hz and 60 Hz (cos φ 0.75 at 20 °C), and the holding power consumption is 7 VA at 50 Hz and 7.5 VA at 60 Hz (cos φ 0.3 at 20 °C). The power loss per pole is 0.36 W for AC-3 and AC-3e, and 1.56 W for AC-1.
Technology Explained Simply
The contactor coil is powered by 48 V AC, ensuring reliable actuation. The operating voltage ranges are defined: for operation at 50 Hz, the range is 0.8 to 1.1 Uc; at 60 Hz, it is 0.85 to 1.1 Uc. At temperatures of 60–70 °C, the operating voltage range is 1.0 to 1.1 Uc. The release voltage is between 0.3 and 0.6 Uc at temperatures from -40 to 70 °C. The rated insulation voltage is 690 V for both the current circuit and the signal circuit, complying with IEC 60947-4-1 and IEC 60947-1. The overvoltage category is III, the pollution degree is 3, and the rated impulse withstand voltage is 6 kV, confirming suitability for industrial environments with increased electrical stress. The rated breaking capacity is 250 A at 440 V for the current circuit according to IEC 60947. The rated short-time current withstand is 105 A at 40 °C for 10 seconds and 210 A at 40 °C for 1 second in the current circuit. In the signal circuit, it is 100 A for 1 second, 120 A for 500 ms, and 140 A for 100 ms. The conventional thermal current (Ith) is 25 A for the current circuit and 10 A for the signal circuit at 60 °C in free air. The rated make capacity is 250 A at 440 V for the current circuit and 140 A AC and 250 A DC for the signal circuit, according to IEC 60947.
Compatibility and Accessories
The contactor is equipped with compatibility code LC1D, enabling use with suitable accessories from the TeSys Deca series. Available accessories include various auxiliary switch blocks such as LADN02A (2 normally open), LADN04A (4 normally open), LADN11A (1 S + 1 Oe), LADN13A (1 S + 3 Oe), LADN20A (2 normally closed), LADN22A (2 S + 2 Oe), LADN31A (3 S + 1 Oe), and LADN40A (4 normally closed), all with SnapIN connection terminals. Additionally, delayed auxiliary switch blocks such as LAD-R4 (10–180 seconds delayed release) and LADT0 (0.10–3.00 s delayed pickup) are available. Time blocks such as LADR2 (1–30.00 s delayed release) and LADT2 (0.10–30.00 s delayed pickup), as well as mechanical interlocks like LAD9V2, are also compatible. Motor protection switches such as GV2ME16A (3p, 9–14 A, push-button actuation) and motor protection relays such as LRD16 (9–13 A, 1S+1Oe, Class 10 A) can be used as supplementary components.
Mounting and Installation
Mounting is done via SnapIN connection terminals, enabling quick, secure, and maintenance-free electrical connections. The terminals are designed for easy and secure connection, reducing installation time. The dimensions of the contactor are 45 mm (width) × 107 mm (height) × 86 mm (depth). The mechanical life is 15 million switching cycles, and the electrical life is 2 million switching cycles at 12 A AC-3 and rated voltage. Safety requirements according to EN/ISO 13849-1 are met, with the B10d level at 1,369,863 cycles under rated load and 20,000,000 cycles under mechanical load. The associated fuse for the signal circuit is 10 A gG according to IEC 60947-5-1.
Operational Advantages
The contactor offers high operational safety through mechanically coupled contacts and mirror contacts, ensuring reliable signal transmission. The SnapIN connection terminals enable quick and secure installation. The high life expectancy and robust construction ensure long-term operation with minimal maintenance. Suitability for various usage categories (AC-1, AC-3, AC-3e, AC-4) and voltage ranges increases flexibility in application. Compliance with standards IEC 60947 and EN/ISO 13849-1 ensures reliability and safety in industrial applications. Heat dissipation is moderate at 2–3 W at 50/60 Hz, reducing thermal load in the enclosure. The maximum operating rate of 3600 cycles per hour at 60 °C allows use in high-dynamic applications.
Coil Technology and Control Circuit
The coil is designed without an integrated wiring module, enabling easy integration into existing control systems. The control circuit voltage is 48 V AC at 50/60 Hz. The control circuit voltage limits are defined: for operation at 50 Hz, the range is 0.8 to 1.1 Uc; at 60 Hz, it is 0.85 to 1.1 Uc. At temperatures of 60–70 °C, the operating voltage range is 1.0 to 1.1 Uc. The release voltage is between 0.3 and 0.6 Uc at temperatures from -40 to 70 °C. The signaling circuit frequency is 25–400 Hz, the minimum switching voltage is 17 V, and the minimum switching current is 5 mA for the signal circuit. The average impedance is 2.5 MΩ at Ith 25 A and 50 Hz for the current circuit.
Insulation and Safety Features
The rated insulation voltage is 690 V for both the current circuit and the signal circuit, complying with IEC 60947-4-1 and IEC 60947-1. The overvoltage category is III, the pollution degree is 3, and the rated impulse withstand voltage is 6 kV, confirming suitability for industrial environments with increased electrical stress. The rated breaking capacity is 250 A at 440 V for the current circuit according to IEC 60947. The rated short-time current withstand is 105 A at 40 °C for 10 seconds and 210 A at 40 °C for 1 second in the current circuit. In the signal circuit, it is 100 A for 1 second, 120 A for 500 ms, and 140 A for 100 ms. The conventional thermal current (Ith) is 25 A for the current circuit and 10 A for the signal circuit at 60 °C in free air. The rated make capacity is 250 A at 440 V for the current circuit and 140 A AC and 250 A DC for the signal circuit, according to IEC 60947. The associated fuse for the signal circuit is 10 A gG according to IEC 60947-5-1.
Mechanical and Electrical Life
The mechanical life is 15 million switching cycles, and the electrical life is 2 million switching cycles at 12 A AC-3 and rated voltage. The B10d level is 1,369,863 cycles under rated load and 20,000,000 cycles under mechanical load according to EN/ISO 13849-1. The maximum operating rate is 3600 cycles per hour at 60 °C. The operating time is 12–22 ms for closing and 4–19 ms for opening. The heat dissipation is 2–3 W at 50/60 Hz. The pickup power is 70 VA at 50 Hz and 60 Hz (cos φ 0.75 at 20 °C), and the holding power consumption is 7 VA at 50 Hz and 7.5 VA at 60 Hz (cos φ 0.3 at 20 °C). The power loss per pole is 0.36 W for AC-3 and AC-3e, and 1.56 W for AC-1.