Schneider Electric LC1D128RD, EAN: 3389110415582

Schneider Electric LC1D128RD contactor 2S+2Ö 25A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D128RD contactor 2S+2Ö 25A

Lieske Part No. 585549
Mfg Part No LC1D128RD
EAN-Code 3389110415582
Manufacturer Schneider Electric
Here only 131,71 EUR
156,73 EUR incl. VAT

Further information for Schneider Electric LC1D128RD contactor 2S+2Ö 25A

Additional features
Compatibility codeLC1D
Pole contact composition2 S + 2 Ö
Safety coverWith
[Ith] conventional thermal current in free air25 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signal circuit
[Irms] Rated making capacity250 A at 440 V for circuits conforming to IEC 60947; 140 A AC for signal circuits conforming to IEC 60947-5-1; 250 A DC for signal circuits conforming to IEC 60947-5-1
Rated breaking capacity250 A at 440 V for circuit, conforms to IEC 60947
[Icw] rated short-time current withstand105 A 40 °C - 10 s for circuit; 210 A 40 °C - 1 s for circuit; 30 A 40 °C - 10 min for circuit; 61 A 40 °C - 1 min for circuit; 100 A - 1 s for signal circuit; 120 A - 500 ms for signal circuit; 140 A - 100 ms for signal circuit
Associated fuse10 A gG for signal circuits, complies with IEC 60947-5-1; 40 A gG at
Average impedance2.5 MOhm - Ith 25 A 50 Hz for circuit
Power dissipation per pole1,56 W AC-1
[Ui] Rated insulation voltageCircuit: 690 V compliant with IEC 60947-4-1; Circuit: 600 V CSA certified; Circuit: 600 V UL certified; Signal circuit: 690 V compliant with IEC 60947-1; Signal circuit: 600 V CSA certified; Signal circuit: 600 V UL certified
Over voltage categoryIII
Pollution degree3
[Uimp] Rated impulse voltage withstand6 kV corresponds to IEC 60947
Security level ratingB10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1
Mechanical life30 Mcycles
Electrical lifetime0.8 Mcycles 25 A AC-1 at Ue
Control circuit typeDC Standard
Coil technologyWith integrated suppression unit
Control circuit voltage limits0.1 - 0.25 Uc (-40…70 °C): drop voltage DC; 0.7 - 1.25 Uc (-40…60 °C): operation DC; 1 - 1.25 Uc (60…70 °C): operation DC
Absorption power in W5.4 W (at 20 °C)
Holding power consumption in W5.4 W at 20 °C
Operating time63 ±15 % ms closing; 20 ±20 % ms opening
Time constant28 ms
Maximum operating rate3600 cyc/h at 60 °C
Tightening momentMain circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Main circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Control circuit: 1.7 Nm - on screw terminals - with flat screwdriver Ø 6; Control circuit: 1.7 Nm - on screw terminals - with Phillips screwdriver No. 2; Control circuit: 1.7 Nm - on screw terminals - with screwdriver position No. 2; Main circuit: 1.7 Nm - on screw terminals - with screwdriver position No. 2
Configuration of auxiliary contacts1 S + 1 Ö
Type of auxiliary contactsMechanically linked type 1 S + 1 NC complies with IEC 60947-5-1; Mirror contact type 1 NO complies with IEC 60947-4-1
Signalling angular frequency25 - 400 Hz
Min. switching voltage17 V for signal circuit
Min. switching current5 mA for signal circuit
Insulation resistance> 10 MΩ for signal circuits
Non-overlapping time1.5 ms with switching between normally open and normally closed contact; 1.5 ms with actuation between normally open and normally closed contact
Mounting bracketRail; Plate
Contractual warranty
Warranty (in months)18
Main features
Product seriesTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Application of contactorresistive load
Application categoryAC-1
Pole description4P
[Ue] Rated operational voltageCircuit:
[Ie] rated operational current25 A (at
[Uc] control circuit voltage440 V DC
Mounting
StandardsCSA C22.2 No. 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No. 60947-4-1
Product certificationsUL; CCC; CSA; Marine; UKCA; EAC; CB-Regulation
Degree of protection (IP)IP20 front side corresponds to IEC 60529
Protection treatmentTH corresponds to IEC 60068-2-30
Climate resistanceComplies with IACS E10 damp heat exposure; complies with IEC 60947-1 Annex Q Category D damp heat exposure
Device ambient temperature-40…60 °C; 60…70 °C with power reduction
Operating altitude0 - 3.000 m
Fire-resistance850 °C corresponds to IEC 60695-2-1
Flame retardancyV1 corresponds to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5 - 300 Hz); vibrations contactor closed (4 Gn, 5 - 300 Hz); shocks contactor open (10 Gn for 11 ms); shocks contactor closed (15 Gn for 11 ms)
Height85 mm
Width45 mm
Depth99 mm
Product weight0,525 kg
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height5,700 cm
VPE 1 width9,700 cm
VPE 1 length12,000 cm
Packaging weight (Lbs)522,000 g
TeSys LC1D power contactor. 4-pole, 2 NO + 2 NC. Additional auxiliary contacts - 1 NO + 1 NC, coil 440 V DC. Dimensions (WxHxD) 45x85x99 mm, weight 0.525 kg. Category AC-1. with integral suppression unit. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications due to mechanically coupled contacts and mirror contacts. Certifications according to CSA, GL, DNV, CCC, UL, BV, LROS (Lloyds register of shipping), RINA, GOST. Product standards in accordance with.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/585549
qrcode für Schneider Electric LC1D128RD contactor 2S+2Ö 25A