Schneider Electric LC1D128P7, EAN: 3389110250008

Schneider Electric LC1D128P7 Contactor 2S+2O 25A

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D128P7 Contactor 2S+2O 25A

Lieske Part No. 457783
Mfg Part No LC1D128P7
EAN-Code 3389110250008
Manufacturer Schneider Electric
Here only 74,03 EUR
88,10 EUR incl. VAT

Further information for Schneider Electric LC1D128P7 Contactor 2S+2O 25A

Complementary
Compatibility codeLC1D
Pole contact composition2 NO + 2 NC
Protective coverWith
[Ith] conventional free air thermal current25 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signalling circuit
Irms rated making capacity250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 40 A gG at
Average impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole1.56 W AC-1
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability15 Mcycles
Electrical durability0.8 Mcycles 25 A AC-1 at Ue
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W at 50/60 Hz
Operating time12...22 ms closing; 4...19 ms opening
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportRail; Plate
Contractual warranty
Warranty (in months)18
Environment
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1
Product certificationsUL; CCC; CSA; Marine; UKCA; EAC; CB Scheme
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor open (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms)
Height85 mm
Width45 mm
Depth92 mm
Net weight0.365 kg
Logistical informations
Country of originID
Main
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current25 A (at
[Uc] control circuit voltage230 V AC 50/60 Hz
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.500 cm
Package 1 Width9.500 cm
Package 1 Length12.000 cm
Package 1 Weight395.000 g
Unit Type of Package 2S02
Number of Units in Package 216
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.740 kg
Unit Type of Package 3P06
Number of Units in Package 3256
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight115.500 kg
The LC1D128P7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 4-pole contactor designed for use in industrial applications. It is intended for resistive loads and corresponds to usage category AC-1. The device features a main circuit contact configuration of 2 NO and 2 NC contacts, along with additional auxiliary contacts comprising 1 NO and 1 NC, mechanically linked. The control circuit voltage is 230 V AC at 50/60 Hz. The contactor is supplied without an integrated wiring module and provides a secure electrical connection via Everlink and spring terminals, enabling quick and easy installation.

Applications
This contactor is designed for use in industrial applications, particularly in systems with resistive loads. The AC-1 category makes it suitable for operating heaters, resistance loads, and similar equipment where inductive or capacitive loads are not present. The mechanically linked contacts and the use of mirror contacts enhance reliability, making the device suitable for safety applications requiring secure signal transmission.

Functions and Features in Detail
The contactor has a rated operational voltage of 690 V for the main circuit, ensuring high insulation strength. The rated insulation voltage is 690 V according to IEC standards, with certifications under CSA and UL also available for 600 V. The rated impulse voltage withstand is 6 kV, providing high robustness against transient voltage surges. The overvoltage category III and pollution degree 3 indicate suitability for industrial environments with increased contamination risk.

Technology Explained Simply
The coil of the contactor is designed for 230 V AC and operates at frequencies of 50/60 Hz. The operating voltage range is between 0.8 and 1.1 times the nominal voltage at temperatures from -40 to 60 °C. The pickup power is 70 VA at 50 Hz and 60 Hz, while the holding power consumption is 7 VA (50 Hz) or 7.5 VA (60 Hz). The operating time is 12–22 ms for closing and 4–19 ms for opening.

Compatibility and Accessories
The contactor is compatible with various accessories, including time delay blocks such as LADR0 (delayed release 0.10–3.00 s) or LADT0 (delayed pickup 0.10–3.00 s), auxiliary switch blocks such as LADN22S (2NO+2NC) or LAD8N02 (2NC delayed, side-mounted), and motor protection circuit breakers such as GV2LE16. Additionally, wiring modules like LAD4RCU (RC network) and varistors like LAD-4VU are available to extend functionality.

Mounting and Installation
Mounting is done via screw terminals with a tightening torque of 1.7 Nm, using flat screwdrivers with Ø 6 or Phillips No. 2. Dimensions are 45 mm (width) × 85 mm (height) × 92 mm (depth). The device is designed for use in enclosures and provides a secure mechanical connection via Everlink technology.

Operational Advantages
The contactor offers high operational safety through mechanically linked contacts and mirror contacts, ensuring secure signal transmission. The use of spring terminals and Everlink technology ensures a reliable electrical connection. Certifications from RINA, GOST, CSA, UL, LROS, DNV, CCC, GL, and BV underline its international applicability. The high mechanical life of 15 million cycles and electrical life of 0.8 million cycles at 25 A AC-1 guarantee long-term operational durability.