| Complementary |
| Compatibility code | LC1D |
| Pole contact composition | 2 NO + 2 NC |
| Protective cover | With |
| [Ith] conventional free air thermal current | 25 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signalling circuit |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 40 A gG at |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole | 1.56 W AC-1 |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 15 Mcycles |
| Electrical durability | 0.8 Mcycles 25 A AC-1 at Ue |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in suppressor module |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 70 VA 60 Hz cos phi 0.75 (at 20 °C); 70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C); 7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 2…3 W at 50/60 Hz |
| Operating time | 12...22 ms closing; 4...19 ms opening |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1 |
| Product certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor open (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms) |
| Height | 85 mm |
| Width | 45 mm |
| Depth | 92 mm |
| Net weight | 0.365 kg |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load |
| Utilisation category | AC-1 |
| Poles description | 4P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 25 A (at |
| [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 9.500 cm |
| Package 1 Length | 12.000 cm |
| Package 1 Weight | 391.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.643 kg |
The LC1D128F7 contactor from the TeSys Deca Advanced series by Schneider Electric is a 4-pole contactor designed for use in industrial applications. It is intended for resistive loads and corresponds to usage category AC-1. The device features a contact configuration of 2 normally closed and 2 normally open contacts in the main circuit, along with additional auxiliary contacts comprising 1 normally closed and 1 normally open contact, mechanically linked to ensure secure signal transmission. The control circuit voltage is 110 V AC at 50/60 Hz, with allowable operating voltage fluctuations between 0.8 and 1.1 times the rated voltage (at -40…60 °C), and up to 1.1 times the rated voltage at higher temperatures (60…70 °C). The coil is designed without an integrated switching module, enabling flexible adaptation to various circuits.
Applications
This contactor is designed for use in industrial applications, particularly in applications involving resistive loads, such as heating systems, resistance operation, or other non-inductive loads. Category AC-1 ensures reliability under continuous load conditions. The mechanically linked auxiliary contacts and mirror contacts make the device suitable for safety applications requiring secure signal transmission and mechanical interlocking. Certifications according to RINA, GL, BV, UL, CSA, CCC, LROS, DNV, and GOST highlight its international applicability across various industries, including shipping and power supply.
Functions and Equipment in Detail
The device offers an operational rating of 25 A in the current circuit and is designed for a rated operating voltage up to 690 V in the current circuit and 600 V in certified variants (CSA, UL). The rated insulation voltage is 690 V for both the current circuit and the signal circuit, with an impulse voltage withstand of 6 kV. Overvoltage category III and pollution degree 3 indicate robustness against electrical and mechanical stresses. The maximum operating rate is 3600 switching operations per hour at 60 °C, enabling high switching frequency. The operating time is 12–22 ms for closing and 4–19 ms for opening, ensuring fast response.
Technology Explained Simply
The contactor’s construction is based on Everlink technology with spring terminals, ensuring a secure and long-lasting electrical connection. The spring terminals allow for easy and quick installation without additional tools. The heat dissipation is 2–3 W at 50/60 Hz, enabling efficient cooling in enclosed enclosures. The pickup power is 70 VA at 50/60 Hz, and the holding power consumption is 7–7.5 VA, ensuring efficient energy use. The rated short-time current withstand is 105 A for 10 seconds and 210 A for 1 second in the current circuit, ensuring safety during short-term overloads.
Compatibility and Accessories
The contactor is compatible with various accessories designed to extend its functionality. These include motor protection relays such as the LRD04 (0.4–0.63 A) or LRD03 (0.25–0.4 A), suitable for motor protection. Auxiliary switch blocks such as the LADN40 (4S) or LADN22 (2S+2O) enable expansion of signal transmission. Time blocks such as the LADT0 (delayed pickup, 0.10–3.00 s) or LADR0 (delayed release, 0.10–3.00 s) provide time-controlled functions. Switching modules such as the LAD4RCG (RC element) or LAD4VG (varistor) can be used for protection against overvoltages or damping switching surges.
Mounting and Installation
Mounting is done via screw terminals with a tightening torque of 1.7 Nm, using flat-blade screwdrivers (Ø 6 mm) or Phillips No. 2. Dimensions are 45 mm (width) × 85 mm (height) × 92 mm (depth), allowing compact installation in standard enclosures. The safety cover is integrated, ensuring safe operation. Installation is in free air, with the conventional thermal current (Ith) being 25 A at 60 °C.
Operational Advantages
The contactor offers a high mechanical life of 15 million switching cycles and an electrical life of 0.8 million cycles at 25 A AC-1. The rated breaking capacity is 250 A at 440 V, ensuring safe interruption under load. The power loss per pole is 1.56 W, enabling efficient heat generation. Certifications according to EN/ISO 13849-1 with a safety level B10d of 1,369,863 cycles (at rated load) and 20,000,000 cycles (mechanical) underscore its reliability in safety-critical applications. The combination of robust design, long service life, and flexible expandability makes the LC1D128F7 a reliable component in industrial control systems.