| Complementary |
| Motor power kW | 30 kW at 220/230 V AC 50/60 Hz (AC-3); 55 kW at 380/400 V AC 50/60 Hz (AC-3); 59 kW at 415/440 V AC 50/60 Hz (AC-3); 75 kW at 500 V AC 50/60 Hz (AC-3); 80 kW at 660/690 V AC 50/60 Hz (AC-3); 65 kW at 1000 V AC 50/60 Hz (AC-3); 30 kW at 220/230 V AC 50/60 Hz (AC-3e); 55 kW at 380/400 V AC 50/60 Hz (AC-3e); 59 kW at 415/440 V AC 50/60 Hz (AC-3e); 75 kW at 500 V AC 50/60 Hz (AC-3e); 80 kW at 660/690 V AC 50/60 Hz (AC-3e); 65 kW at 1000 V AC 50/60 Hz (AC-3e); 18.5 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
| Irms rated making capacity | 1260 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 250 A 40 °C - 10 min for power circuit; 550 A 40 °C - 1 min for power circuit; 950 A 40 °C - 10 s for power circuit; 1100 A 40 °C - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 250 A gG at |
| Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole | 24 W AC-1; 7.9 W AC-3; 7.9 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Power circuit: 1000 V conforming to IEC 60947-4-1; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| Electrical durability | 0.8 Mcycles 200 A AC-1 at Ue |
| Control circuit type | AC at 50/60 Hz standard |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz; 1...1.15 Uc (55…70 °C):operational AC 50/60 Hz |
| Inrush power in VA | 280…350 VA 60 Hz cos phi 0.8 (at 20 °C); 280…350 VA 50 Hz cos phi 0.8 (at 20 °C) |
| Hold-in power consumption in VA | 2…18 VA 60 Hz cos phi 0.3 (at 20 °C); 2…18 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation | 3…8 W at 50/60 Hz |
| Operating time | 6...20 ms opening; 20...50 ms closing |
| Maximum operating rate | 2400 cyc/h at 60 °C |
| Tightening torque | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2; Power circuit: 12 N.m - on connector hexagonal screw head 4 mm; Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; IEC 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1 |
| Product certifications | UL; CSA; CCC; UKCA; CE; EAC; Marine |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor closed (15 Gn for 11 ms) ; Shocks contactor open (6 Gn for 11 ms) |
| Height | 158 mm |
| Width | 120 mm |
| Depth | 136 mm |
| Net weight | 2.5 kg |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 200 A (at |
| [Uc] control circuit voltage | 400 V AC 50/60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 19.000 cm |
| Package 1 Width | 17.500 cm |
| Package 1 Length | 21.500 cm |
| Package 1 Weight | 2.448 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.360 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 16 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 53.372 kg |
The LC1D115V7 contactor from the TeSys series by Schneider Electric is a 3-pole contactor for controlling motors and resistive loads. It is designed for use in industrial plants where reliable and safe switching of electrical current is required. The device features an integrated bidirectional amplitude limiter diode, which protects the coil from transient voltage spikes and increases the component's service life. The control circuit voltage is 400 V AC at 50/60 Hz, making it suitable for standard industrial applications.
Applications
This contactor is designed for motor control and operation of resistive loads. It covers usage categories AC-1, AC-3, AC-3e, and AC-4, with AC-3 being the typical category for three-phase motor operation. At 400 V AC and category AC-3, the rated operational current Ie is 115 A, corresponding to a rated operational power of 55 kW. Motor power ratings according to UL/CSA standards include 30 hp at 200/208 V, 40 hp at 230/240 V, 75 hp at 460/480 V, and 100 hp at 575/600 V, all for 3-phase motors. These values demonstrate the versatility of the contactor across various voltage ranges.
Functions and Equipment in Detail
The device features 3 normally closed contacts in the main circuit and additional auxiliary contacts configured as 1 normally closed + 1 normally open. The auxiliary contacts are mechanically linked and comply with IEC 60947-5-1, ensuring secure and reliable signal transmission. The contacts are suitable for use in safety applications, as they are mechanically coupled and feature mirror contacts, enhancing reliability for critical functions. Electrical connections are made via Everlink and spring terminals, ensuring a secure and long-lasting connection.
Technology Explained Simply
The contactor coil is rated for 400 V AC and operates at frequencies of 50/60 Hz. Operating voltage variations range from 0.8–1.15 Uc at -40…55 °C and 1–1.15 Uc at 55…70 °C, enabling stable performance under variable conditions. The pickup power is 280…350 VA at 50/60 Hz, while the holding power consumption is between 2…18 VA. The operating time is 6–20 ms for opening and 20–50 ms for closing, enabling fast response during switching operations. The maximum operating rate is 2400 switching operations per hour at 60 °C, highlighting its suitability for frequent switching operations.
Compatibility and Accessories
The contactor is compatible with various accessories, including auxiliary switch blocks such as LADN04 (4 normally open), LADN02 (2 normally open), LADN11 (1 NO + 1 NC), LADN20 (2 normally closed), and LADN31 (3 NO + 1 NC). Time delay blocks such as LADT0 (pickup delayed 0.10–3.00 s) or LADT2 (pickup delayed 0.10–30.00 s) can be used to extend functionality. Additionally, delayed auxiliary switch blocks such as LAD-S2 (operating delayed 1–30 s) or LAD-R4 (release delayed 10–180 s) are available. These components extend the functionality of the contactor for specific applications.
Mounting and Installation
Mounting is done via screw terminals, with a tightening torque of 1.2 Nm for control circuit terminals (using flat screwdriver Ø 6 or Phillips No. 2). For main circuit terminals, the torque is 12 Nm (hexagonal socket head screws 4 mm). The dimensions of the contactor are 120 mm (width) × 158 mm (height) × 136 mm (depth), and the net weight is 2.5 kg. Installation requires qualified personnel, as these are electrical devices whose malfunction can lead to hazards.
Operational Advantages
The contactor offers a high mechanical life of 8 million switching cycles and an electrical life of 0.8 million switching cycles at 200 A AC-1. The rated breaking capacity is 1100 A at 440 V, enhancing safety during short-circuit events. The rated impulse voltage withstand is 8 kV, and the overvoltage category is III, confirming suitability for industrial environments with high electrical stress. The power loss per pole is 24 W at AC-1 and 7.9 W at AC-3 and AC-3e, highlighting the efficiency of the device. Certifications according to CCC, GOST, CSA, UL, LROS, BV, GL, RINA, and DNV confirm the international applicability of the contactor.