| Additional features |
| Motor power (kW) | 2.2 kW at 220/230 V AC 50/60 Hz (AC-3); 4 kW at 380/400 V AC 50/60 Hz (AC-3); 4 kW at 415/440 V AC 50/60 Hz (AC-3); 5.5 kW at 500 V AC 50/60 Hz (AC-3); 5.5 kW at 660/690 V AC 50/60 Hz (AC-3); 2.2 kW at 400 V AC 50/60 Hz (AC-4) |
| Compatibility code | LC1D |
| Pole contact composition | 3 S |
| Safety cover | With |
| [Ith] conventional thermal current in free air | 10 A (at 60 °C) for control circuit; 25 A (at 60 °C) for power circuit |
| [Irms] Rated making capacity | 140 A AC for control circuit conforming to IEC 60947-5-1; 250 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 250 kA at 440 V for circuit in accordance with IEC 60947 |
| Associated fuse | 10 A fuse type gG for control circuit in accordance with IEC 60947-5-1; 20 A at |
| Average impedance | 2.5 MOhm - Ith 25 A 50 Hz for circuit |
| Power dissipation per pole | 0,2 W AC-3; 1,56 W AC-1; 0,2 W AC-3e |
| [Ui] Rated insulation voltage | Control circuit: 600 V CSA certified; Control circuit: 600 V UL certified; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Control circuit: 690 V complies with IEC 60947-4-1; Power circuit: 690 V complies with IEC 60947-4-1 |
| Over voltage category | III |
| [Uimp] Rated impulse voltage withstand | 6 kV corresponds to IEC 60947 |
| Security level rating | B10d = 1369863 cycles contactor with rated load corresponds to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load corresponds to EN/ISO 13849-1 |
| Mechanical life | 15 Mcycles |
| Control circuit type | AC at 50/60 Hz |
| Coil technology | Without built-in amplitude limiting diode |
| Control circuit voltage limits | 0.3 - 0.6 Uc (60 °C): Dropout voltage AC 50/60 Hz; 0.8 - 1.1Uc (60 °C): Operation AC 50 Hz; 0.85 - 1.1 Uc (60 °C): Operation AC 60 Hz |
| Input power in VA | 70 VA cos phi 0,75 (bei 20 °C) |
| Hold power consumption in VA | 7 VA 50/60 Hz cos phi 0.3 (at 20 °C) |
| Heat emission | 2…3 W at 50/60 Hz for control circuit |
| Operating time | 4 - 19 ms opening; 12 - 22 ms closing |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening moment | Control circuit: 1.7 Nm - with flat screwdriver Ø 6; control circuit: 1.7 Nm - with Phillips screwdriver No. 2; power circuit: 1.7 Nm - with flat screwdriver Ø 6; power circuit: 1.7 Nm - with Phillips screwdriver No. 2; control circuit: 1.7 Nm - with screwdriver position No. 2; power circuit: 1.7 Nm - with screwdriver position No. 2 |
| Configuration of auxiliary contacts | 1 S + 1 Ö |
| Min. switching voltage | 17 V for control circuit |
| Min. switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlapping time | 1.5 ms with misoperation between normally closed contacts and normally open contacts; 1.5 ms with actuation between normally closed contacts and normally open contacts |
| Mounting bracket | Rail; Plate |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | TeSys; TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Application of contactor | Resistive load; motor control |
| Application category | AC-3; AC-3e; AC-1 |
| Pole description | 3P |
| [Ue] Rated operational voltage | Circuit: |
| [Ie] rated operational current | 9 A (at |
| [Uc] control circuit voltage | 48 V AC 50/60 Hz |
| Mounting |
| Standards | CSA C22.2 No. 14; EN/IEC 60947-5-1; UL 60947-4-1; EN/IEC 60947-4-1; IEC 60335-1 |
| Product certifications | CCC; DNV; RINA; GOST; UL; CSA; LROS (Lloyds register of shipping); GL; BV; UKCA |
| Degree of protection (IP) | IP2x corresponds to IEC 60529; IP2x corresponds to VDE 0106 |
| Climate resistance | Complies with IACS E10 damp heat exposure; complies with IEC 60947-1 Annex Q Category D damp heat exposure |
| Device ambient temperature | -5…60 °C; -40…70 °C at Uc |
| Operating altitude | 3,000 m without power derating |
| Fire-resistance | 850 °C corresponds to IEC 60695-2-1 |
| Flame retardancy | V1 corresponds to UL 94 |
| Mechanical robustness | Shocks contactor open (10 Gn for 11 ms); Shocks contactor closed (15 Gn for 11 ms); Vibrations contactor open (2 Gn, 5 - 300 Hz); Vibrations contactor closed (4 Gn, 5 - 300 Hz) |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Product weight | 3,2 kg |
| Quantity per set | Set of 10 pieces |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 4,500 cm |
| VPE 1 width | 7,700 cm |
| VPE 1 length | 8,500 cm |
| Packaging weight (Lbs) | 336,000 g |
| VPE 2 type | S02 |
| VPE 2 quantity | 24 |
| VPE 2 height | 15,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 8,600 kg |
| VPE 3 type | P06 |
| VPE 3 quantity | 192 |
| VPE 3 height | 44,000 cm |
| VPE 3 width | 60,000 cm |
| VPE 3 length | 80,000 cm |
| VPE 3 weight | 146,000 kg |
TeSys LC1D power contactor. 3-pole, 3 NO contacts. Additional auxiliary contacts - 1 NO + 1 NC contact, rated operating power at AC-3, 400 V 4 kW, rated operating current Ie at AC-3, 400 V 9 A, coil 48 V AC. Dimensions (WxHxD) 45x77x86 mm, weight 3.2 kg. Category AC-1, AC-3. without built-in amplitude limiter diode. Quick and easy setup. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications due to mechanically coupled contacts and mirror contacts. Certifications according to CCC, DNV, RINA, GOST, UL, CSA, LROS (Lloyds register of shipping), GL, BV. Product standards according to CSA C22.2 No 14, EN/IEC 60947-5-1, UL 508, EN/IEC 60947-4-1.