| Complementary |
| Motor power kW | 2.2 kW at 220/230 V AC 50/60 Hz (AC-3); 4 kW at 380/400 V AC 50/60 Hz (AC-3); 4 kW at 415/440 V AC 50/60 Hz (AC-3); 5.5 kW at 500 V AC 50/60 Hz (AC-3); 5.5 kW at 660/690 V AC 50/60 Hz (AC-3); 2.2 kW at 220/230 V AC 50/60 Hz (AC-3e); 4 kW at 380/400 V AC 50/60 Hz (AC-3e); 4 kW at 415/440 V AC 50/60 Hz (AC-3e); 5.5 kW at 500 V AC 50/60 Hz (AC-3e); 5.5 kW at 660/690 V AC 50/60 Hz (AC-3e); 2.2 kW at 400 V AC 50/60 Hz (AC-4) |
| Motor power hp | 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors; 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 25 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signalling circuit |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 25 A gG at |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole | 1.56 W AC-1; 0.2 W AC-3; 0.2 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 0.6 Mcycles 25 A AC-1 at Ue |
| Control circuit type | DC low consumption |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.1...0.3 Uc (-40…70 °C):drop-out DC; 0.8...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC |
| Inrush power in W | 2.4 W (at 20 °C) |
| Hold-in power consumption in W | 2.4 W at 20 °C |
| Operating time | 77 ±15 % ms closing; 25 ±20 % ms opening |
| Time constant | 40 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate; Rail |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1 |
| Product certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C; 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor open (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms) |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 95 mm |
| Net weight | 0.48 kg |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range of product | TeSys Deca Advanced |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load; Motor control |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: |
| [Ie] rated operational current | 9 A (at |
| [Uc] control circuit voltage | 24 V DC |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 9.200 cm |
| Package 1 Length | 11.200 cm |
| Package 1 Weight | 528.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 15 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.182 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 240 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 138.000 kg |
The LC1D09BL contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor drives and resistive loads. It features an integrated bidirectional amplitude limiter diode in the coil, which increases the coil's lifespan and protects switching operations. The control circuit voltage is 24 V DC, enabling use in systems with direct current power supply. The rated operational current Ie is 9 A at AC-3, enabling a motor power of 4 kW at 400 V AC 50/60 Hz. The rated insulation voltage for the current circuit is 690 V according to IEC 60947-4-1, making the device suitable for industrial applications. The overvoltage category III and pollution degree 3 indicate suitability for demanding operating conditions.
Applications
The contactor is designed for controlling motors and resistive loads in industrial plants. It is used in categories AC-1, AC-3, AC-3e, and AC-4, with AC-3 being the standard category for motor drives. The motor power is 4 kW at 400 V AC 50/60 Hz (AC-3), making it suitable for medium-sized drive applications. The maximum operating rate is 3600 switching operations per hour at 60 °C, enabling high dynamics in operation. The mechanical life is 30 million switching cycles, and the electrical life is 0.6 million cycles at 25 A AC-1.
Functions and Equipment in Detail
The device features 3 closers in the main current circuit and additional auxiliary contacts: 1 closer and 1 opener, connected front-side. The contacts are mechanically coupled and feature mirror contacts, increasing reliability in safety applications. The current connection is made via Everlink technology with spring terminals, ensuring a secure and long-lasting connection. The coil is equipped with an integrated bidirectional peak-limiting diode suppressor, protecting switching operations and increasing lifespan. The pickup power is 2.4 W at 20 °C, and the holding power consumption is also 2.4 W at 20 °C.
Technology Explained Simply
The integrated bidirectional amplitude limiter diode in the coil reduces voltage peaks during switching off, extending the coil's lifespan and increasing reliability. The Everlink technology with spring terminals enables quick and secure installation without additional tools. The mechanical coupling of contacts ensures that main contacts and auxiliary contacts switch synchronously, which is important for safety applications. The rated impulse voltage withstand is 6 kV, demonstrating robustness against transient voltage peaks.
Compatibility and Accessories
The contactor is compatible with various accessories, including connection blocks such as LA9D3260, protective covers such as LAD9ET1 or LAD9ET1S, and mechanical interlocks such as LAD9V2. For reversing contactor applications, the kit LAD9R1V is available. Additionally, motor protection circuit breakers such as GV2P14 or GV2L14 can be combined to achieve complete motor control. Auxiliary switch blocks such as LADN11 (1NO1NC) or LADN02 (2NC) extend functionality. Certifications according to GL, UL, LROS, CCC, RINA, BV, GOST, DNV, and CSA demonstrate international usability.
Mounting and Installation
Mounting is done via Everlink technology with spring terminals, enabling quick and secure connections. Dimensions are 45 mm (width) × 77 mm (height) × 95 mm (depth), allowing installation in standard control panels. The operating time is 77 ±15 % ms for closing and 25 ±20 % ms for opening. The time constant is 40 ms. The coil is designed for operating voltages between 0.8 and 1.25 Uc at -40…60 °C, with operation up to 1.25 Uc possible at 60…70 °C.
Operational Advantages
The contactor offers high reliability through mechanically coupled contacts and mirror contacts, which is crucial for safety applications. The integrated diode protection technology extends the coil's lifespan. The Everlink technology enables quick and secure installation. The high mechanical life of 30 million cycles and electrical life of 0.6 million cycles at AC-1 ensure long service life. Certifications according to international standards enable use in global installations.