Schneider Electric LC1D09BL, EAN: 3389110361070

Schneider Electric LC1D09BL Contactor 3p 24VDC

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LC1D09BL Contactor 3p 24VDC

Lieske Part No. 168197
Mfg Part No LC1D09BL
EAN-Code 3389110361070
Manufacturer Schneider Electric
Here only 73,06 EUR
86,94 EUR incl. VAT

Further information for Schneider Electric LC1D09BL Contactor 3p 24VDC

Complementary
Motor power kW2.2 kW at 220/230 V AC 50/60 Hz (AC-3); 4 kW at 380/400 V AC 50/60 Hz (AC-3); 4 kW at 415/440 V AC 50/60 Hz (AC-3); 5.5 kW at 500 V AC 50/60 Hz (AC-3); 5.5 kW at 660/690 V AC 50/60 Hz (AC-3); 2.2 kW at 220/230 V AC 50/60 Hz (AC-3e); 4 kW at 380/400 V AC 50/60 Hz (AC-3e); 4 kW at 415/440 V AC 50/60 Hz (AC-3e); 5.5 kW at 500 V AC 50/60 Hz (AC-3e); 5.5 kW at 660/690 V AC 50/60 Hz (AC-3e); 2.2 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp1 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors; 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors; 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors; 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors; 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current25 A (at 60 °C) for power circuit; 10 A (at 60 °C) for signalling circuit
Irms rated making capacity250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current105 A 40 °C - 10 s for power circuit; 210 A 40 °C - 1 s for power circuit; 30 A 40 °C - 10 min for power circuit; 61 A 40 °C - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1; 25 A gG at
Average impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole1.56 W AC-1; 0.2 W AC-3; 0.2 W AC-3e
[Ui] rated insulation voltagePower circuit: 690 V conforming to IEC 60947-4-1; Power circuit: 600 V CSA certified; Power circuit: 600 V UL certified; Signalling circuit: 690 V conforming to IEC 60947-1; Signalling circuit: 600 V CSA certified; Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability30 Mcycles
Electrical durability0.6 Mcycles 25 A AC-1 at Ue
Control circuit typeDC low consumption
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Control circuit voltage limits0.1...0.3 Uc (-40…70 °C):drop-out DC; 0.8...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC
Inrush power in W2.4 W (at 20 °C)
Hold-in power consumption in W2.4 W at 20 °C
Operating time77 ±15 % ms closing; 25 ±20 % ms opening
Time constant40 ms
Maximum operating rate3600 cyc/h at 60 °C
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1; type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25...400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Mounting supportPlate; Rail
Contractual warranty
Warranty (in months)18
Environment
StandardsCSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ; CSA C22.2 No 60947-4-1
Product certificationsUL; CCC; CSA; Marine; UKCA; EAC; CB Scheme
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat; conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C; 60…70 °C with derating
Operating altitude0...3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5...300 Hz) ; Vibrations contactor closed (4 Gn, 5...300 Hz) ; Shocks contactor open (10 Gn for 11 ms) ; Shocks contactor closed (15 Gn for 11 ms)
Height77 mm
Width45 mm
Depth95 mm
Net weight0.48 kg
Logistical informations
Country of originFR
Main
Range of productTeSys Deca Advanced
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load; Motor control
Utilisation categoryAC-3; AC-3e; AC-1; AC-4
Poles description3P
[Ue] rated operational voltagePower circuit:
[Ie] rated operational current9 A (at
[Uc] control circuit voltage24 V DC
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width9.200 cm
Package 1 Length11.200 cm
Package 1 Weight528.000 g
Unit Type of Package 2S02
Number of Units in Package 215
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.182 kg
Unit Type of Package 3P06
Number of Units in Package 3240
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight138.000 kg
The LC1D09BL contactor from the TeSys Deca Advanced series by Schneider Electric is a 3-pole contactor for controlling electrical loads, particularly for motor drives and resistive loads. It features an integrated bidirectional amplitude limiter diode in the coil, which increases the coil's lifespan and protects switching operations. The control circuit voltage is 24 V DC, enabling use in systems with direct current power supply. The rated operational current Ie is 9 A at AC-3, enabling a motor power of 4 kW at 400 V AC 50/60 Hz. The rated insulation voltage for the current circuit is 690 V according to IEC 60947-4-1, making the device suitable for industrial applications. The overvoltage category III and pollution degree 3 indicate suitability for demanding operating conditions.

Applications

The contactor is designed for controlling motors and resistive loads in industrial plants. It is used in categories AC-1, AC-3, AC-3e, and AC-4, with AC-3 being the standard category for motor drives. The motor power is 4 kW at 400 V AC 50/60 Hz (AC-3), making it suitable for medium-sized drive applications. The maximum operating rate is 3600 switching operations per hour at 60 °C, enabling high dynamics in operation. The mechanical life is 30 million switching cycles, and the electrical life is 0.6 million cycles at 25 A AC-1.

Functions and Equipment in Detail

The device features 3 closers in the main current circuit and additional auxiliary contacts: 1 closer and 1 opener, connected front-side. The contacts are mechanically coupled and feature mirror contacts, increasing reliability in safety applications. The current connection is made via Everlink technology with spring terminals, ensuring a secure and long-lasting connection. The coil is equipped with an integrated bidirectional peak-limiting diode suppressor, protecting switching operations and increasing lifespan. The pickup power is 2.4 W at 20 °C, and the holding power consumption is also 2.4 W at 20 °C.

Technology Explained Simply

The integrated bidirectional amplitude limiter diode in the coil reduces voltage peaks during switching off, extending the coil's lifespan and increasing reliability. The Everlink technology with spring terminals enables quick and secure installation without additional tools. The mechanical coupling of contacts ensures that main contacts and auxiliary contacts switch synchronously, which is important for safety applications. The rated impulse voltage withstand is 6 kV, demonstrating robustness against transient voltage peaks.

Compatibility and Accessories

The contactor is compatible with various accessories, including connection blocks such as LA9D3260, protective covers such as LAD9ET1 or LAD9ET1S, and mechanical interlocks such as LAD9V2. For reversing contactor applications, the kit LAD9R1V is available. Additionally, motor protection circuit breakers such as GV2P14 or GV2L14 can be combined to achieve complete motor control. Auxiliary switch blocks such as LADN11 (1NO1NC) or LADN02 (2NC) extend functionality. Certifications according to GL, UL, LROS, CCC, RINA, BV, GOST, DNV, and CSA demonstrate international usability.

Mounting and Installation

Mounting is done via Everlink technology with spring terminals, enabling quick and secure connections. Dimensions are 45 mm (width) × 77 mm (height) × 95 mm (depth), allowing installation in standard control panels. The operating time is 77 ±15 % ms for closing and 25 ±20 % ms for opening. The time constant is 40 ms. The coil is designed for operating voltages between 0.8 and 1.25 Uc at -40…60 °C, with operation up to 1.25 Uc possible at 60…70 °C.

Operational Advantages

The contactor offers high reliability through mechanically coupled contacts and mirror contacts, which is crucial for safety applications. The integrated diode protection technology extends the coil's lifespan. The Everlink technology enables quick and secure installation. The high mechanical life of 30 million cycles and electrical life of 0.6 million cycles at AC-1 ensure long service life. Certifications according to international standards enable use in global installations.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/168197
qrcode für Schneider Electric LC1D09BL Contactor 3p 24VDC