| Complementary |
| Irms rated making capacity | 140 A at |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 5 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid; Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid; Screw clamp terminals |
| Tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2 |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 61 mm |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -40…70 °C |
| Operating altitude | 3000 m |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Time delay auxiliary contact block |
| Range compatibility | TeSys Deca CAD; TeSys Deca LC1D; TeSys F LC1F; TeSys F CR1F |
| Mounting location | Front |
| Pole contact composition | 1 NO + 1 NC |
| Contacts operation | Time delay |
| Timer type | On delay |
| Time delay range | 10...180 s |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | IECEE CB Scheme; UL; CSA; CCC; EAC; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.2 cm |
| Package 1 Width | 6.5 cm |
| Package 1 Length | 5.0 cm |
| Package 1 Weight | 74.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 5.2 cm |
| Package 2 Width | 14.0 cm |
| Package 2 Length | 24.0 cm |
| Package 2 Weight | 750.0 g |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 140 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 10.988 kg |
The LADT4 from Schneider Electric is a time-delayed auxiliary switch block from the TeSys Deca product series, specifically designed for integration into power contactors of the TeSys Deca CAD, TeSys Deca LC1D, TeSys F LC1F, and TeSys F CR1F series. It functions as an
ansprechverzögerter Zeitblock (ansprechverzögerter Zeitblock) and enables a controlled, time-delayed switching function when the main contact is actuated. The delay occurs during switching-on operations and ranges from 10 to 180 seconds, allowing for time-synchronized switching operations in industrial installations. The switch block is mounted front-side and can therefore be directly attached to the front of the main contactor. The configuration includes a
Schließer (S) and an
Öffner (Ö), with contacts connected via screw terminals. The terminals are designed for flexible and rigid conductor cross-sections from 1 to 2.5 mm², allowing connection with or without wire ends. The tightening torque is 1.7 Nm, and mounting can be done using a flat-head screwdriver (Ø 6 mm) or a Phillips screwdriver (No. 2).
Applications include industrial control systems where time-synchronized switching operations are required, for example in motor, pump, or other drive control, where delayed switching-on or switching-off is necessary to reduce mechanical stress or ensure process sequence. The device is intended for use in normal environmental conditions, with an operating temperature range from -40 °C to +70 °C. Storage is permitted at temperatures from -60 °C to +80 °C. The operating altitude is up to 3,000 meters above sea level.
Functions and features in detail include an
on-delay, which is activated when the contactor is actuated. The delay is non-overlapping, ensuring a safe transition between the normally open and normally closed contacts — the non-overlapping time is 1.5 ms, regardless of whether actuation occurs via control or release. The contacts are rated for an operating voltage of 690 V AC (25–400 Hz), with an insulation voltage rating of 690 V (IEC 60947-5-1) or 600 V (UL/CSA). The
rated operational current is 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. The mechanical life is 5 million switching cycles, ensuring high reliability in industrial applications. The
conventional thermal current in free air is 10 A at an ambient temperature of 60 °C. The permissible short-time current is 100 A for 1 second, 120 A for 500 ms, and 140 A for 100 ms at 60 °C. The
rated make capacity is 140 A. The
insulation resistance is greater than 10 MΩ, ensuring high electrical insulation. The
degree of protection is IP20 according to IEC 60529, providing protection against finger contact and against solid foreign objects larger than 12.5 mm. The coating corresponds to category TH according to IEC 60068, indicating high resistance to environmental conditions.
Technology explained simply shows that the LADT4 functions as an auxiliary contact block that can be mounted onto existing contactors to enable additional switching functions with time delay. The time delay is generated by an integrated mechanism that delays the switching time as soon as the main contact is actuated. The screw terminals allow for secure and reliable connections with cables having a cross-section of 1 to 2.5 mm², supporting both flexible and rigid conductors. Front-side mounting allows for easy integration into existing control systems without additional installation work. The device is dark grey in color, with dimensions of 44 mm (width), 48 mm (height), and 61 mm (depth).
Compatibility and accessories include use with various contactor types from the TeSys Deca and TeSys F series, such as LC1D, LC1F, CAD, and CR1F. Compatibility is ensured by the mounting method (front-side snap-on) and electrical specifications. Compatible accessory products available in the range include various power contactors and auxiliary contactors from the TeSys series, such as LC1D128ED, LC1D115Q7, LC1D50AF7, LC1D80D7, LC1D115G7, LC1D25S7, LC1D150Q7, LC1D12U7, CAD32UD, CAD32X7, CAD32B7, CAD50B7, and LC1DT40ED. These can be combined according to application configuration to realize complex switching functions.
Mounting and installation are performed by snapping the time block onto the front of the main contactor. The screw terminals are connected to the respective conductors, ensuring the specified tightening torque of 1.7 Nm is maintained. Mounting is simple and requires no additional tools beyond a suitable screwdriver. Positioning typically occurs in enclosures or control cabinets, with environmental conditions remaining within the specified limits.
Operational advantages include high reliability due to the long mechanical life of 5 million switching cycles, secure switching function due to the non-overlapping time of 1.5 ms, and easy mounting. The time delay enables precise control of processes, thereby extending the service life of machines and systems. High insulation strength and high insulation resistance ensure safe electrical isolation. Compatibility with various contactor types increases flexibility in system design.
The standards the device complies with include EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, EN 50012, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, and UL 60335-2-40:Annex JJ. Product certifications include the IECEE CB Scheme, UL, CSA, CCC, EAC, and UKCA. The warranty period is 18 months.