| Complementary |
| Irms rated making capacity | 140 A AC; 250 A DC |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 5 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Lugs-ring terminals (external diameter: 8 mm) |
| Tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2 |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 61 mm |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -40…70 °C |
| Operating altitude | 3000 m |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Time delay auxiliary contact block |
| Range compatibility | TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D |
| Mounting location | Front |
| Pole contact composition | 1 NO + 1 NC |
| Contacts operation | Time delay |
| Timer type | On delay |
| Time delay range | 1...30 s |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB; UL; CSA; CCC; EAC; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.8 cm |
| Package 1 Width | 5.3 cm |
| Package 1 Length | 6.6 cm |
| Package 1 Weight | 73 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 13.3 cm |
| Package 2 Width | 24.3 cm |
| Package 2 Length | 5.2 cm |
| Package 2 Weight | 755 g |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 140 |
| Package 3 Height | 30 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 10.712 kg |
The article LADT26 from Schneider Electric is a
time-delayed auxiliary switch block from the
TeSys Deca series, specifically designed for integration into contactors of the series TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, as well as TeSys Deca CAD and TeSys Deca LC1D. It serves as an
on-delayed auxiliary switch with an
on-delay time ranging from 1 to 30 seconds, enabling time-controlled operation of auxiliary functions in industrial systems. The block features a
configuration of 1 close contact and 1 open contact (1 S + 1 Ö) and is mounted on the
front side of the contactor.
Applications
LADT26 is used in industrial control and switching systems where a time-delayed activation of auxiliary contacts is required. Typical applications include controlling warning lights, signals, or auxiliary functions that should only be activated after a defined delay following the main contact closure. The delay range of 1 to 30 seconds allows flexible adaptation to various process requirements. Compatibility with multiple contactor series from the TeSys family makes it a universally applicable component in automation technology.
Functions and Equipment in Detail
The auxiliary switch block is designed for an
operating voltage rating of 690 V AC at frequencies from 25 to 400 Hz. The
rated insulation voltage is 690 V according to IEC 60947-5-1, 600 V according to UL and CSA. The
rated operating currents are 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. The
conventional thermal current is 10 A at an ambient temperature of 60 °C. The
mechanical life expectancy is specified at 5 million switching cycles, indicating high reliability under industrial operating conditions. The
minimum switching voltage is 17 V, and the
minimum switching current is 5 mA, ensuring usability even under low-load conditions.
Technology Explained Simply
The
on-delay is achieved through an integrated timing mechanism that closes or opens the contact only after the set delay time (1–30 s) has elapsed. The
non-overlapping time is 1.5 ms, meaning that the open and close contacts are not active simultaneously during switching — this prevents short circuits and enhances safety. The
insulation resistance is greater than 10 MΩ, ensuring high electrical insulation and safe operation. Connections are made via
ring terminal lugs with an outer diameter of 8 mm, to be tightened with a torque of 1.7 Nm (using a flat screwdriver Ø 6, Phillips No. 2, or position No. 2). The
protection rating IP2x according to IEC 60529 protects against finger contact and larger solid objects, but is not waterproof.
Compatibility and Accessories
The LADT26 is specifically designed for mounting on contactors from the series TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, TeSys Deca CAD, and TeSys Deca LC1D. It can be combined with various power contactors, including models such as LC1D1506MD, LC1D1506N7, LC1D40A6P7, LC1D1506FD, LC1D386FD, LC1D1156B7, LC1D1286P7, LC1D096MD, LC1D1506B7, LC1D186F7, LC1D1506BD, LC1D386CD, CAD326B7, LC1D40A6LE7, LC1D096B7, LC1D1156M5, LC1D126B7, LC1D386F7, LC1D096F7, and LC1D126L7. These contactors cover a power range from 0.06 to 75 kW and are available in various voltage and current classes. This combination enables flexible expansion of control functions in existing systems.
Mounting and Installation
The auxiliary switch block is mounted on the front side of the contactor and is designed for normal ambient conditions. The operating temperature range is from -40 °C to +70 °C, and the storage temperature range is from -60 °C to +80 °C. The maximum operating altitude is 3,000 m above sea level. The dimensions of the device are 44 mm (width), 48 mm (height), and 61 mm (depth). The color is dark gray. Mounting is done by mechanical fastening to the front plate of the contactor, with terminals designed for ring terminal lugs.
Operational Advantages
The LADT26 provides a reliable and low-maintenance solution for time-delayed control functions. The high mechanical life expectancy of 5 million switching cycles and robust construction ensure long service life. Clear compatibility with TeSys contactors and simple front-side mounting facilitate integration into existing systems. Compliance with international standards such as EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, EN 50012, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, and UL 60335-2-40:Annex JJ ensures safety and compatibility in various markets. Product certifications include CB, UL, CSA, CCC, EAC, and UKCA, supporting worldwide usability.