| Complementary |
| Irms rated making capacity | 140 A at |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 5 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid; Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid; Screw clamp terminals |
| Tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2 |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 61 mm |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -40…70 °C |
| Operating altitude | 3000 m |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Time delay auxiliary contact block |
| Range compatibility | TeSys Deca CAD; TeSys Deca LC1D; TeSys F LC1F; TeSys F CR1F |
| Mounting location | Front |
| Pole contact composition | 1 NO + 1 NC |
| Contacts operation | Time delay |
| Timer type | On delay |
| Time delay range | 1...30 s |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | IECEE CB Scheme; UL; CSA; CCC; EAC; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.2 cm |
| Package 1 Width | 6.5 cm |
| Package 1 Length | 5 cm |
| Package 1 Weight | 74 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 5.2 cm |
| Package 2 Width | 13 cm |
| Package 2 Length | 24 cm |
| Package 2 Weight | 752 g |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 140 |
| Package 3 Height | 30 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 11 kg |
The terminals are designed for cable cross-sections of 1 to 2.5 mm² flexible (with or without cable end) and 1 to 2.5 mm² rigid. The tightening torque is 1.7 Nm, and installation can be performed using a flat screwdriver Ø 6, Phillips No. 2, or Position No. 2.
Applications include use in industrial control systems where a time-delayed switching function is required for auxiliary functions such as start-up control, safety shutdowns, or signal delays. The module is
front-mounted snap-in into the corresponding contactors, allowing it to be integrated into existing control systems without requiring additional mounting components. The
rated operational voltage is 690 V AC in the frequency range of 25 to 400 Hz. The
rated insulation voltage is 690 V according to IEC 60947-5-1, 600 V according to UL 60947-5-1, and CSA C22.2 No. 60947-5-1. The
rated operational currents depend on voltage and load type: 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13.
Technology explained simply: The time delay occurs when the contactor is energized, with the contact switching only after the set delay time. This enables controlled, delayed activation of auxiliary functions. The
mechanical life is 5 million switching cycles, indicating high durability in industrial applications. The
permissible short-time current is 100 A at 60 °C for 1 second, 120 A for 500 ms, and 140 A for 100 ms. The module is equipped with a
GG fuse 10 A to protect against overloads. The
conventional thermal current in free air is 10 A at 60 °C. The
insulation resistance is greater than 10 MΩ, ensuring high electrical insulation.
Compatibility and accessories: The module is specifically designed for integration into the specified TeSys contactor series. The product list includes various power contactors from the LC1D and LC1F series that are compatible with the LADT2, such as LC1D65AMD, LC1D38BD, LC1D150V7, LC1D50ASD, LC1D258B7, LC1D80F7, LC1D25X7, LC1D18M7, LC1D80P7, LC1D50AU7, LC1D80V7, LC1D258V7, LC1D18FD, LC1DT40E7, LC1D258SD, and LC1D80AE7. These can be combined with the time block to implement time-delayed auxiliary functions.
Mounting and installation: Mounting is done by front snap-in into the corresponding contactors. Dimensions are 44 mm width, 48 mm height, and 61 mm depth. The color is dark gray. The
protection rating IP20 according to IEC 60529 protects against finger contact and solid foreign objects, but is not suitable for outdoor use or humid environments. The
operating ambient temperature ranges from -40 °C to +70 °C, and the
storage temperature ranges from -60 °C to +80 °C. The maximum operating altitude is 3,000 m above sea level. The
coating corresponds to category TH according to IEC 60068, indicating high resistance to environmental influences.
Operational advantages: Integration into existing contactors enables flexible expansion of control functions without additional components. The time delay of 1 to 30 seconds offers sufficient flexibility for various applications. The high mechanical life and robust construction with screw terminals ensure reliable performance in industrial environments. Certifications according to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, EN 50012, as well as IEC 60335-1:Clause 30.2 and IEC 60335-2-40:Annex JJ, guarantee compliance with international safety and quality standards. Product certifications include IECEE CB Scheme, UL, CSA, CCC, EAC, and UKCA.
The module is available in single packaging (PCE), with one unit per pack. The warranty is 18 months.