| Complementary |
| Irms rated making capacity | 140 A AC; 250 A DC |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 5 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Spring terminals 2 cable(s) 2.5 mm²flexible without cable end; Spring terminals 2 cable(s) 2.5 mm²rigid |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 61 mm |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -40…70 °C |
| Operating altitude | 3000 m |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Time delay auxiliary contact block |
| Range compatibility | TeSys D CAD; TeSys D LC1D; TeSys Deca CAD; TeSys Deca LC1D |
| Mounting location | Front |
| Pole contact composition | 1 NO + 1 NC |
| Contacts operation | Time delay |
| Timer type | On delay |
| Time delay range | 0.3...3 s |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB; UL; CSA; CCC; EAC; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.2 cm |
| Package 1 Width | 6.5 cm |
| Package 1 Length | 4.7 cm |
| Package 1 Weight | 80.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 5.2 cm |
| Package 2 Width | 13.5 cm |
| Package 2 Length | 24.0 cm |
| Package 2 Weight | 800.0 g |
| Unit Type of Package 3 | S02 |
| Number of Units in Package 3 | 70 |
| Package 3 Height | 15.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 5.812 kg |
The
Schneider Electric LADT03 is a
time-delayed auxiliary switch block from the
TeSys Deca series, specifically designed for integration into power contactors of the TeSys D CAD, TeSys D LC1D, TeSys Deca CAD and TeSys Deca LC1D series. It serves as an
on-delay element and enables a time-delayed switching function when actuating the main contact, with the delay time adjustable between
0.3 and 3 seconds. The function is implemented via a
spring-loaded connection, ensuring a secure and durable connection. The block features a
composition of 1 normally open contact (S) and 1 normally closed contact (Ö), making it suitable for complex control logic in industrial applications.
Applications include the control of drives, pumps, heating systems and other electrical loads where delayed activation is required to reduce mechanical stress or ensure the sequence of process steps. The
on-delay function ensures that the auxiliary switch only operates after the set time has elapsed, which is useful for synchronizing machines or avoiding current surges.
Functions and equipment in detail include an
operating voltage rating of 690 V AC in the frequency range of 25 to 400 Hz. The
operating current ratings are 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13 and 0.1 A at 600 V DC-13. The
conventional thermal current in free air is 10 A at 60 °C, defining the load capacity under normal operating conditions. The
rated insulation voltage is 690 V according to IEC 60947-5-1, 600 V according to UL and CSA. The
rated make capacity is 140 A AC and 250 A DC, describing the ability to safely switch under load.
Technology explained simply shows that the LADT03 features
spring terminals designed for
2 cables with 2.5 mm² cross-section, suitable for both flexible and rigid conductors. The
protection rating IP2x according to IEC 60529 protects against contact with fingers and larger objects, but is not waterproof. The
TH coating corresponds to IEC 60068, ensuring resistance to environmental influences such as humidity and temperature fluctuations. The
operating ambient temperature ranges from -40 °C to +70 °C, with storage up to +80 °C permitted. The
operating altitude is up to 3,000 m above sea level.
Compatibility and accessories include use with various power contactors from the TeSys D and TeSys Deca series, such as LC1D65A3FE7, LC1D40A3BD or LC1D65A3B7. The mentioned contactors are available in various configurations with different current ratings, voltages and pole numbers, and their combination with the LADT03 enables time-delayed control. The
mechanical life is 5 million switching cycles, indicating high reliability in industrial applications. The
minimum switching voltage is 17 V, the
minimum switching current is 5 mA, defining the sensitivity of the contact. The
non-overlapping time is 1.5 ms, ensuring safe separation between the normally closed and normally open contacts to prevent short circuits.
Mounting and installation take place on the
front side of the contactor, with dimensions of
44 mm width, 48 mm height and 61 mm depth, enabling compact integration into existing control systems. The color is
dark grey, matching the standard appearance of the TeSys Deca series. The
insulation resistance is greater than 10 MΩ, ensuring electrical safety. The
permissible short-time performance is 100 A at 1 second, 120 A at 500 ms and 140 A at 100 ms at 60 °C, describing the load capacity under short-term overloads.
Operational advantages lie in the
safe and precise time delay, required for controlling complex processes. The
high mechanical life and
certified compliance with standards such as EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, EN 50012 as well as IEC 60335-1 and -2-40 guarantee reliability and safety. The
product certifications CB, UL, CSA, CCC, EAC and UKCA confirm international applicability. The
warranty is 18 months.
The LADT03 is thus a
reliable auxiliary switch block for industrial controls, suitable for demanding applications due to its
on-delay function,
high service life and
international certifications. The
combination with TeSys contactors enables flexible and safe control of electrical loads in manufacturing, power supply and automation technology.