| Complementary |
| Irms rated making capacity | 140 A AC; 250 A DC |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 5 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Lugs-ring terminals (external diameter: 8 mm) |
| Tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2 |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 61 mm |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -40…70 °C |
| Operating altitude | 3000 m |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Time delay auxiliary contact block |
| Range compatibility | TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D |
| Mounting location | Front |
| Pole contact composition | 1 NO + 1 NC |
| Contacts operation | Time delay |
| Timer type | Off delay |
| Time delay range | 1...30 s |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB; UL; CSA; CCC; EAC; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.5 cm |
| Package 1 Width | 5 cm |
| Package 1 Length | 5 cm |
| Package 1 Weight | 75 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 5.2 cm |
| Package 2 Width | 13 cm |
| Package 2 Length | 24 cm |
| Package 2 Weight | 760 g |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 140 |
| Package 3 Height | 30 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 11.155 kg |
The auxiliary switch block LADR26 from Schneider Electric belongs to the TeSys Deca series and serves as a time-delayed auxiliary switch block for mounting on the front side of power contactors from the TeSys D and TeSys F series. It is specifically designed for applications requiring a controlled, time-delayed switching function, for example, to avoid short-circuit currents or to synchronize switching operations in industrial controls. The block features an off-delay in the range of 1 to 30 seconds and is equipped with a contact configuration of 1 normally open and 1 normally closed contact (1S + 1Oe). The time delay is of the delayed-off type, meaning the contact returns to its rest position with a delay after the control current is switched off.
Applications
The LADR26 is designed for use in industrial plants where time-controlled switching operations are required. Typical applications include the control of motors, pumps, or heating systems, where a controlled shutdown process or a delay between switching operations is necessary. Compatibility with various contactor types from the TeSys D and TeSys F families enables flexible integration into existing installations. The protection rating IP2x according to IEC 60529 protects against finger contact and provides basic protection against foreign objects, but does not protect against water or dust.
Functions and Equipment in Detail
The auxiliary switch block is designed for an operating voltage of up to 690 V AC (25–400 Hz) and supports various rated operating currents, depending on voltage and load type. At 120 V AC-15, the rated operating current is 6 A; at 690 V AC-15, it is 1.04 A. For direct current (DC), the values are 0.55 A at 125 V DC-13 and 0.1 A at 600 V DC-13. The rated insulation voltage is 690 V (IEC 60947-5-1), 600 V (UL), and 600 V (CSA). The mechanical life expectancy is 5 million switching cycles, ensuring high reliability under long-term operating conditions. The minimum switching voltage is 17 V, and the minimum switching current is 5 mA, enabling secure operation even under low-load conditions.
Technology Explained Simply
The time delay is achieved through an electromechanical mechanism that causes a delayed reset of the contact after the control current is switched off. The delay time is adjustable between 1 and 30 seconds, allowing precise adaptation to the requirements of the respective installation. The contacts are designed so that no overlap occurs between the normally open and normally closed contacts — during switching and actuation, the non-overlapping time is 1.5 ms. This prevents brief short circuits or false signals. The insulation resistance is over 10 MΩ, ensuring safe electrical isolation. Connections are made via ring terminal lugs with an outer diameter of 8 mm, to be fastened with a tightening torque of 1.7 Nm (using a flat screwdriver Ø 6, Phillips No. 2, or position No. 2).
Compatibility and Accessories
The LADR26 is compatible with various contactor types from the TeSys D and TeSys F series, including models such as LC1D096L7, LC1D326K7, LC1D800046P7, LC1D1156P7, LC1D806F7, LC1D1506K7, LC1D50A6F7, LC1D1156FD, LC1D40A6G7, LC1D1506P7, LC1D50A6B7, LC1D096P7, LC1D326P7, LC1D1156L7, LC1D386B7, LC1D806P7, LC1D096Q7, and LC1D956P7. Mounting is done directly on the front side of the contactors, with the block’s dimensions (height 48 mm, width 44 mm, depth 61 mm) enabling compact integration. The block’s color is dark gray, allowing visual harmonization with other components in the TeSys series.
Mounting and Installation
Mounting is performed on the front side of the power contactor, with the terminals fastened using a tightening torque of 1.7 Nm. The use of ring terminal lugs with an 8 mm outer diameter ensures a secure and durable connection. The operating temperature range is from -40 °C to +70 °C, and the storage temperature range is from -60 °C to +80 °C. The maximum operating altitude is 3,000 m above sea level. The IP2x protection rating provides basic protection against contact and foreign objects, but does not offer protection against water or dust.
Advantages in Operation
The LADR26 provides a reliable, time-delayed switching function with high mechanical life expectancy and precise time control. Compatibility with a wide range of contactor types in the TeSys series enables flexible use in various installations. The combination of compact design and high functionality makes it a valuable component in industrial controls. Compliance with international standards such as EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, EN 50012, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, and UL 60335-2-40:Annex JJ ensures safe and standard-compliant application. Product certifications include CB, UL, CSA, CCC, EAC, and UKCA, supporting worldwide usability.