Schneider Electric LADR2, EAN: 3389110386189

Schneider Electric LADR2 Contactor Delayed Release 1-30s

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LADR2 Contactor Delayed Release 1-30s

Lieske Part No. 365754
Mfg Part No LADR2
EAN-Code 3389110386189
Manufacturer Schneider Electric
Here only 96,90 EUR
115,31 EUR incl. VAT

Further information for Schneider Electric LADR2 Contactor Delayed Release 1-30s

Complementary
Irms rated making capacity140 A at
Permissible short-time rating100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms
Protection typeGG fuse 10 A
Mechanical durability5 Mcycles
Minimum switching current5 mA
Minimum switching voltage17 V
Non-overlap time1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance> 10 MOhm
Connections - terminalsScrew clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid; Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid; Screw clamp terminals
Tightening torque1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2
Height48 mm
Width44 mm
Depth61 mm
ColourDark grey
Contractual warranty
Warranty (in months)18
Environment
Environmental characteristicNormal environment
IP degree of protectionIP20 conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for storage-60…80 °C
Ambient air temperature for operation-40…70 °C
Operating altitude3000 m
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys Deca
Product or component typeTime delay auxiliary contact block
Range compatibilityTeSys Deca CAD; TeSys Deca LC1D; TeSys F LC1F; TeSys F CR1F
Mounting locationFront
Pole contact composition1 NO + 1 NC
Contacts operationTime delay
Timer typeOff delay
Time delay range1...30 s
[Ue] rated operational voltage690 V AC 25...400 Hz
[Ie] rated operational current6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
[Ui] rated insulation voltage690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1
[Ith] conventional free air thermal current10 A (at 60 °C)
StandardsEN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certificationsIECEE CB Scheme; UL; CSA; CCC; EAC; UKCA
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.200 cm
Package 1 Width6.500 cm
Package 1 Length5.000 cm
Package 1 Weight74.000 g
Unit Type of Package 2BB1
Number of Units in Package 210
Package 2 Height5.200 cm
Package 2 Width13.000 cm
Package 2 Length24.000 cm
Package 2 Weight756.000 g
Unit Type of Package 3S03
Number of Units in Package 3140
Package 3 Height30.000 cm
Package 3 Width30.000 cm
Package 3 Length40.000 cm
Package 3 Weight11.121 kg
The LADR2 is a time-delayed auxiliary switch block from the TeSys Deca series by Schneider Electric, specifically designed for integration into contactors of the TeSys Deca CAD, TeSys Deca LC1D, TeSys F LC1F, and TeSys F CR1F series. As a drop-out delayed time block, it enables controlled delay during switching off, allowing better control and synchronization of switching operations in industrial plants. The function is implemented via an off-delay type, providing a delay time range of 1 to 30 seconds. This adjustable range is suitable for applications requiring precise timing coordination of switching operations, such as sequential motor starts or avoiding short-term current surges.

Applications include industrial automation, particularly in systems where targeted time delay is required when switching off auxiliary functions. The time block is mounted directly on the front side of the contactor, enabling compact and quick installation. Mounting is done by snap-on, ensuring a mechanically robust and reliable connection. The protection rating IP20 according to IEC 60529 protects against finger contact and ingress of solid foreign objects larger than 12.5 mm, but not against water or dust—thus, it is intended for indoor installations under normal environmental conditions.

Functions and equipment in detail include a pole contact configuration of 1 normally open (S) and 1 normally closed (Oe). The contacts are rated for an operating voltage of 690 V AC, with permissible operating currents varying by voltage: 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. The conventional thermal current is 10 A at an ambient temperature of 60 °C, defining the thermal load capacity under operating conditions. The rated insulation voltage is 690 V according to IEC 60947-5-1, 600 V according to UL 60947-5-1, and CSA C22.2 No. 60947-5-1, ensuring electrical insulation for safe operation.

Technology explained simply shows that the time block operates via a mechanical time delay activated during switching off. The delay is achieved through a mechanical timing mechanism that slows the reset of the contacts. The non-overlapping time is 1.5 ms, regardless of whether the switch is operated control-based or release-based, ensuring that the normally closed and normally open contacts are never active simultaneously. This prevents short circuits and enhances reliability. The permissible short-time current is 100 A for 1 second, 120 A for 500 ms, and 140 A for 100 ms at 60 °C, defining the mechanical load capacity under sudden current surges. The rated make capacity is 140 A, indicating the maximum current during switching on. The mechanical life is 5 million switching cycles, indicating high robustness and longevity.

Compatibility and accessories include use with various contactor models from the TeSys Deca and TeSys F series, such as LC1D80ABBE, LC1D50AU7, LC1D09JD, LC1DT25MD, LC1D258V7, LC1DT32F7, LC1D80AE7, LC1DT80AE7, LC1D098FD, LC1DT40E7, LC1D95MD, LC1D65ABBE, LC1D50AP7, LC1D50AEHE, LC1D40AX7, LC1DT25BD, LC1D65AR7, LC1D09G7, LC1D09SD, and LC1D150FD. These contactors can be combined with the LADR2 to integrate additional time-delay functions for auxiliary contacts. Connections are made via screw terminals, suitable for cable cross-sections of 1 to 2.5 mm² flexible (with or without cable end) and 1 to 2.5 mm² rigid. The torque is 1.7 Nm, and mounting can be done with a flat screwdriver (Ø 6), a Phillips screwdriver No. 2, or a positioning screwdriver No. 2.

Mounting and installation is done by simple snap-on to the front side of the contactor, requiring no additional tools or mounting aids. Dimensions are 48 mm height, 44 mm width, and 61 mm depth, allowing integration into standardized control panels. The color is dark gray, contributing to visual harmony in industrial control systems. The ambient temperature during operation ranges from -40 °C to +70 °C, and during storage from -60 °C to +80 °C. The maximum operating altitude is 3,000 m above sea level, enabling use in high-altitude industrial facilities. The insulation resistance is greater than 10 MΩ, ensuring high electrical insulation. The coating corresponds to category TH according to IEC 60068, indicating resistance to environmental influences such as humidity and temperature fluctuations.

Operational advantages include high reliability, a long life of 5 million switching cycles, and easy mounting. The 1 to 30-second time delay enables precise control of switching operations, enhancing operational safety in industrial plants. Certifications according to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, EN 50012, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, as well as product certifications IECEE CB-Scheme, UL, CSA, CCC, EAC, and UKCA, guarantee compliance with international standards. Compliance with RoHS and REACH (Green Premium) ensures environmental compatibility of the product. The minimum switching voltage is 17 V, and the minimum switching current is 5 mA, defining the sensitivity of the switch to weak signals. The protection rating GG fuse 10 A protects the time block against overloads and short circuits.

The LADR2 is thus a reliable, standard-compliant auxiliary switch block for industrial applications, used in control systems of the TeSys Deca and TeSys F series due to its easy mounting, long life, and precise time-delay functions. Technical specifications and norm compliance ensure safe and reliable operation under industrial conditions.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/365754
qrcode für Schneider Electric LADR2 Contactor Delayed Release 1-30s