Schneider Electric LADR0, EAN: 3389110386141

Schneider Electric LADR0 time delay relay release delayed 0,10-3,00s

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LADR0 time delay relay release delayed 0,10-3,00s

Lieske Part No. 391202
Mfg Part No LADR0
EAN-Code 3389110386141
Manufacturer Schneider Electric
Here only 97,38 EUR
115,88 EUR incl. VAT

Further information for Schneider Electric LADR0 time delay relay release delayed 0,10-3,00s

Complementary
Irms rated making capacity140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1
Permissible short-time rating100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms
Protection typeGG fuse 10 A
Mechanical durability5 Mcycles
Minimum switching current5 mA
Minimum switching voltage17 V
Non-overlap time1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance> 10 MOhm
Connections - terminalsScrew clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid; Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid; Screw clamp terminals
Tightening torque1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2
Height48 mm
Width44 mm
Depth61 mm
ColourDark grey
Contractual warranty
Warranty (in months)18
Environment
Environmental characteristicNormal environment
IP degree of protectionIP20 conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for storage-60…80 °C
Ambient air temperature for operation-40…70 °C
Operating altitude3000 m
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys Deca
Product or component typeTime delay auxiliary contact block
Range compatibilityTeSys Deca CAD; TeSys Deca LC1D; TeSys F LC1F; TeSys F CR1F
Mounting locationFront
Pole contact composition1 NO + 1 NC
Contacts operationTime delay
Timer typeOff delay
Time delay range0.3...3 s
[Ue] rated operational voltage690 V AC 25...400 Hz
[Ie] rated operational current6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
[Ui] rated insulation voltage690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1
[Ith] conventional free air thermal current10 A (at 60 °C)
StandardsEN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certificationsIECEE CB Scheme; UL; CSA; CCC; EAC; UKCA
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.200 cm
Package 1 Width6.500 cm
Package 1 Length5.000 cm
Package 1 Weight75.000 g
Unit Type of Package 2S03
Number of Units in Package 2140
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight11.070 kg
Unit Type of Package 3P06
Number of Units in Package 31120
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight99.324 kg
The LADR0 is a time-delayed auxiliary switch block from the TeSys Deca series by Schneider Electric, specifically designed for mounting on contactors of the series TeSys Deca CAD, TeSys Deca LC1D, TeSys F LC1F and TeSys F CR1F. It functions as a drop-out delayed time block and enables precise control of switching operations with an off-delay ranging from 0.3 to 3 seconds. Mounting is simple by clipping onto the front side of the contactor, ensuring compact and reliable integration into existing installations.

Applications
This time block is used in industrial control systems where a time-delayed de-energization of auxiliary contacts is required, for example, to avoid short-circuit currents in motors or to synchronize process steps. It is suitable for applications in manufacturing automation, machine building industry, and installations with complex control logic. The operating temperature ranges from -40 °C to +70 °C, making it usable even in environments with extreme temperatures. The maximum operating altitude is 3,000 meters above sea level, making it suitable for use in mountainous regions or high-performance installations.

Functions and Equipment in Detail
The LADR0 features a contact configuration of 1 normally open (S) + 1 normally closed (Oe), suitable for a wide range of control tasks. The rated operational voltage is 690 V AC in the frequency range of 25 to 400 Hz, with rated operational currents varying depending on voltage: 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. The rated insulation voltage is 690 V according to IEC 60947-5-1, ensuring high electrical safety. The mechanical life is 5 million switching cycles, indicating high robustness and longevity.

Technology Explained Simply
The time delay occurs when the control current is switched off, causing the contact to close or open not immediately, but after a set delay of 0.3 to 3 seconds. This is particularly useful for reducing mechanical stress or ensuring time-synchronized sequences. The non-overlap time is 1.5 ms, meaning there is no overlap between opening and closing of the contacts, which is important for safe switching operations. The insulation resistances are greater than 10 MΩ, ensuring high electrical insulation and safety. Connections are made via screw terminals, suitable for cable cross-sections of 1 to 2.5 mm², either flexible or rigid. The torque is 1.7 Nm, and mounting can be done using a flat-head screwdriver (Ø 6), a Phillips screwdriver No. 2, or a positioning screwdriver No. 2.

Compatibility and Accessories
The LADR0 is compatible with contactor series TeSys Deca CAD, TeSys Deca LC1D, TeSys F LC1F, and TeSys F CR1F. It can be combined with various power contactors, including models such as LC1D12U7, LC1D50AV7, LC1DT25FD, LC1D95F7, LC1D115R7, LC1D150U7, LC1D25SD, LC1D09Y7, LC1DT32P7, LC1D32EHE, LP1D80004BD, LC1D18P7, LC1D115G7, LC1D50ABBE, LC1DT25JD, LC1DT60ABD, LC1D65AB7, and LC1D098BD. These combinations allow flexible adaptation to different power requirements and control systems.

Mounting and Installation
Mounting is done by simply clipping onto the front side of the contactor, requiring no additional mounting aids or tools. The protection rating IP20 according to IEC 60529 protects against finger contact and against entry of solid foreign objects larger than 12.5 mm, but not against water or dust. The coating TH conforms to IEC 60068 and ensures high resistance to environmental influences. The dimensions are 44 mm (width), 48 mm (height), and 61 mm (depth), allowing easy integration into standardized enclosures.

Operational Advantages
The LADR0 offers high reliability due to its long mechanical life and precise time delay. The multi-standard certification according to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, EN 50012, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, and UL 60335-2-40:Annex JJ ensures compliance with international safety and quality standards. Additionally, the device is RoHS/REACH-compliant, ensuring environmental compatibility and the use of non-hazardous materials. The warranty is 18 months, underscoring the quality and reliability of the product.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/391202
qrcode für Schneider Electric LADR0 time delay relay release delayed 0,10-3,00s