| Complementary |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1 |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 30 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Lugs-ring terminals (external diameter: 8 mm) |
| Tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm M3.5; 1.7 N.m - with screwdriver Philips No 2 M3.5; 1.7 N.m - with screwdriver pozidriv No 2 M3.5 |
| Height | 48 mm |
| Width | 26 mm |
| Depth | 42 mm |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -5…60 °C |
| Operating altitude | 3000 m |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Auxiliary contact block |
| Device short name | LADN |
| Range compatibility | TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D |
| Mounting location | Front |
| Pole contact composition | 1 NO + 1 NC |
| Contacts operation | Instantaneous |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; GB/T 14048.5; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; UL; CSA; CCC; EAC; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.000 cm |
| Package 1 Width | 4.000 cm |
| Package 1 Length | 5.000 cm |
| Package 1 Weight | 33.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 320 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 11.016 kg |
The auxiliary switch block LADN116 from Schneider Electric belongs to the TeSys Deca series and serves as an additional component for contactors. It is designed as an
auxiliary switch block and features a
contact configuration of 1 normally open (S) and 1 normally closed (Ö). The contacts operate
instantaneously, meaning they switch directly upon actuation of the main contact, without any time delay. The switch block is mounted on the
front side of the contactor and is intended for use in industrial control systems and switchgear.
Applications include signal transmission in control circuits, for example, to indicate the switching state of a contactor, to provide feedback to a control system, or to interlock switching operations. It is compatible with various product families, including TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, TeSys Deca CAD, and TeSys Deca LC1D. This compatibility enables flexible integration into existing installations with different contactor types.
Functions and specifications in detail include an operating voltage rating of up to 690 V AC in the frequency range of 25 to 400 Hz. The
rated operating current is 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. The
rated insulation voltage is 690 V according to IEC 60947-5-1, 600 V according to UL, and 600 V according to CSA. The
conventional thermal current is 10 A at an ambient temperature of 60 °C. The mechanical life is specified as 30 million switching cycles (Mcycles), indicating high durability in industrial applications.
Technology explained simply shows that the auxiliary switch block is designed for operation under normal environmental conditions. The
protection rating IP20 according to IEC 60529 protects against finger contact and solid foreign objects, but is not waterproof. The
coating TH corresponds to IEC 60068 and ensures a certain resistance to environmental influences. The
permissible short-time current is 100 A at 60 °C for 1 second, 120 A for 500 ms, and 140 A for 100 ms, highlighting its capability to handle short-term overloads. The
insulation resistance is greater than 10 MΩ, ensuring high electrical insulation.
Compatibility and accessories include use with various contactors from the TeSys and TeSys Deca series, such as LC1D1156F5, LC1D80A6P7, LC1D096ND, or LC1D1506F7. These contactors cover power ranges from 0.06 to 75 kW, enabling broad application in industrial environments. Combining them with these contactors allows expansion of control functions without additional components.
Mounting and installation is performed on the front side of the contactor. The terminals consist of
ring cable lug terminals with an outer diameter of 8 mm. The
tightening torque is 1.7 Nm, and mounting can be done using a flathead screwdriver (Ø 6, M3,5), a Phillips screwdriver (No. 2, M3,5), or a positioning screwdriver (No. 2, M3,5). The dimensions of the device are 48 mm height, 26 mm width, and 42 mm depth. The color is dark gray.
Operational advantages include high mechanical life, reliability at high switching cycles, and easy installation. The instantaneous switching function enables precise signal transmission. Compliance with international standards such as EN/IEC 60947-5-1, UL 60947-5-1, and CSA C22.2 No. 60947-5-1, as well as certifications like CB Scheme, UL, CSA, CCC, EAC, and UKCA, ensure safety and worldwide use. The operating temperature range is from -5 °C to 60 °C, and the storage temperature range is from -60 °C to 80 °C. The maximum operating altitude is 3,000 m above sea level.
The auxiliary switch block is designed for use in industrial installations where reliable and durable signal transmission is required. It is an integral part of control and protection systems in automation technology.