| Complementary |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1 |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms |
| Protection type | GG fuse 10 A |
| Mechanical durability | 30 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Lugs-ring terminals (external diameter: 8 mm) |
| Tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm M3.5; 1.7 N.m - with screwdriver Philips No 2 M3.5; 1.7 N.m - with screwdriver pozidriv No 2 M3.5 |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 42 mm |
| Net weight | 0.05 kg |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -60…80 °C |
| Ambient air temperature for operation | -5…60 °C |
| Operating altitude | 3000 m |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Auxiliary contact block |
| Device short name | LADN |
| Range compatibility | TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D |
| Mounting location | Front |
| Pole contact composition | 4 NC |
| Contacts operation | Instantaneous |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; GB/T 14048.5; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; UL; CSA; CCC; EAC; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.200 cm |
| Package 1 Width | 4.700 cm |
| Package 1 Length | 5.100 cm |
| Package 1 Weight | 58.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 80 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.035 kg |
The auxiliary switch block LADN046 from Schneider Electric belongs to the TeSys Deca series and serves as an undelayed auxiliary contact block for power contactors of the LC1D, LC1F series, as well as the TeSys D and TeSys Deca product families. It is specifically designed for front mounting and enables the expansion of switching functions of contactors through additional contacts. The block features four normally closed contacts (NC), which can be used for monitoring switching states, controlling additional components, or signal transmission in control systems. The contacts are designed as
NC mirror certified, ensuring high reliability and clear switching behavior.
Applications
The auxiliary switch block is used in industrial plants where additional signal transmission or state monitoring is required. It is suitable for applications in automation technology, such as in machine controls, drive technology, or in combination with contactors in electrical distributions. Mounting is done directly on the front side of the contactor, enabling compact and secure integration into existing control systems. Typical use is in combination with power contactors such as LC1D326GD, LC1D65A6U7, or LC1D1156BD, with exact compatibility adjusted to the respective contactor module.
Functions and Equipment in Detail
The block provides four undelayed normally closed contacts, rated for an operating voltage of 690 V AC (25–400 Hz). The operating current ratings are 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. The contacts are designed for a conventional thermal current load of 10 A at 60 °C. The minimum switching voltage is 17 V, and the minimum switching current is 5 mA, enabling secure switching even under low load conditions. The non-overlapping time is 1.5 ms, ensuring no overlap between normally closed and normally open contacts during actuation and de-actuation, which is important for precise control signals.
Technology Explained Simply
The contacts are designed as
normally closed contacts (NC), meaning they are closed in the resting state and open when the contactor is actuated. Switching occurs undelayed, without mechanical delay elements. Connections are made via
ring terminal lugs with an outer diameter of 8 mm, to be tightened with a torque of 1.7 Nm. This can be done using a flat screwdriver Ø 6 M3,5, a Phillips screwdriver No. 2 M3,5, or a position screwdriver No. 2 M3,5. The insulation resistance exceeds 10 MΩ, ensuring high electrical safety. The permissible short-time current is 100 A at 60 °C for 1 second, 120 A for 500 ms, and 140 A for 100 ms, ensuring robustness under transient current surges.
Compatibility and Accessories
The auxiliary switch block is compatible with contactor series TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, TeSys Deca CAD, and TeSys Deca LC1D. It can be combined with various power contactors, such as LC1D80A6P7, LC1D326GD, LC1D65A6U7, or LC1D1156BD, to extend control functions. Combination with auxiliary contactors such as CAD326FD or CAD506P7 is also possible, with exact application adjusted to the respective switching logic. Mounting is done via a clip-on system on the front side of the contactor, enabling quick and secure installation.
Mounting and Installation
Mounting is done on the front side of the contactor using a clip-on system, ensuring a secure and reliable fixation. Cable connections are made via ring terminal lugs with an outer diameter of 8 mm. The tightening torque is 1.7 Nm, with fastening done using a flat, Phillips, or position screwdriver (M3,5). The dimensions of the block are 44 mm (width), 48 mm (height), and 42 mm (depth). The color is dark gray, providing good visibility in control enclosures. The operating temperature range is from -5 °C to 60 °C, and the storage temperature range is from -60 °C to 80 °C. The operating altitude is up to 3,000 m above sea level.
Advantages in Operation
The auxiliary switch block offers a high mechanical life of 30 million switching cycles, enabling long service life and low maintenance frequency. Certifications according to EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, EN 50012, as well as compliance with RoHS/REACH (Green Premium), ensure adherence to international safety and environmental standards. The protection rating IP20 corresponds to IEC 60529 and protects against finger contact and solid foreign objects. The coating corresponds to category TH according to IEC 60068, ensuring high resistance to environmental influences. The rated switching capacity is 140 A AC and 250 A DC, ensuring suitability for demanding applications. The protection rating GG fuse 10 A provides additional safety in case of overloads.
Product certifications include CB regulation, UL, CSA, CCC, EAC, and UKCA, enabling worldwide use in various markets. The warranty period is 18 months.