Schneider Electric LADN02, EAN: 3389110383768

Schneider Electric LADN02 auxiliary switch block 2NO front

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LADN02 auxiliary switch block 2NO front

Lieske Part No. 993670
Mfg Part No LADN02
EAN-Code 3389110383768
Manufacturer Schneider Electric
Here only 11,64 EUR
13,85 EUR incl. VAT

Further information for Schneider Electric LADN02 auxiliary switch block 2NO front

Complementary
Irms rated making capacity140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1
Permissible short-time rating100 A 1 s; 120 A 500 ms; 140 A 100 ms
Protection typeGG fuse 10 A
Mechanical durability30 Mcycles
Minimum switching current5 mA
Minimum switching voltage17 V
Non-overlap time1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance> 10 MOhm
Connections - terminalsScrew clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end; Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable end
Tightening torque1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2
Height48 mm
Width26 mm
Depth42 mm
ColourDark grey
Contractual warranty
Warranty (in months)18
Environment
Environmental characteristicNormal environment
IP degree of protectionIP20 conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068
Ambient air temperature for storage-60…80 °C
Ambient air temperature for operation-5…60 °C
Operating altitude3000 m
Logistical informations
Country of originFR
Main
RangeTeSys; TeSys Deca
Product nameTeSys Deca
Product or component typeAuxiliary contact block
Device short nameLADN
Range compatibilityTeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D
Mounting locationFront
Pole contact composition2 NC
Contacts operationInstantaneous
[Ue] rated operational voltage690 V AC 25...400 Hz
[Ie] rated operational current6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
[Ui] rated insulation voltage690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA
[Ith] conventional free air thermal current10 A (at 60 °C)
StandardsEN/IEC 60947-5-1; GB/T 14048.5; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certificationsCB Scheme; UL; CSA; CCC; EAC; UKCA
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5 cm
Package 1 Width2.8 cm
Package 1 Length4.3 cm
Package 1 Weight34 g
Unit Type of Package 2S03
Number of Units in Package 2320
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight11.55 kg
The auxiliary switch block LADN02 from Schneider Electric belongs to the TeSys Deca product range and serves as an add-on component for contactors of the series TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, as well as TeSys Deca CAD and TeSys Deca LC1D. It is specifically designed for front mounting and enables the integration of auxiliary contacts into existing control systems. The block features two normally open contacts (2 NO) and is designed for instantaneous switching operations, making it suitable for applications requiring precise signal transmission.

Auxiliary switch block

The LADN02 is an auxiliary switch block that functions as an extension for contactors. It is mounted front-side onto the contactor housing, providing a compact and quick way to implement additional switching functions such as signal transmission, feedback, or control of auxiliary circuits. The design is modular, allowing it to be directly attached to the designated connection points of compatible contactors without additional mounting tools.

Applications

The auxiliary switch block is used in industrial control and switching systems where extending switching functions through additional contacts is required. Typical applications include providing feedback of a contactor’s switching status to a control system, actuating auxiliary relays, or signal transmission in automated production environments. Its use is primarily in installations with low-voltage systems up to 690 V AC and 600 V DC.

Functions and equipment in detail

The block features two normally open contacts that switch instantaneously. The contacts are rated for an operating voltage of 690 V AC (25–400 Hz). The rated operating current is 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. The mechanical life expectancy is 30 million switching cycles, ensuring high reliability in industrial applications. The minimum switching voltage is 17 V, and the minimum switching current is 5 mA, enabling use even with weak signals.

Technology explained simply

The screw terminals of the LADN02 allow connection with cables having a cross-section of 1 to 4 mm², both flexible and rigid, with or without wire end ferrules. The tightening torque is 1.7 Nm, and installation is performed using a flat-head screwdriver (Ø 6 mm) or a Phillips screwdriver (No. 2). Insulation strength is ensured by an insulation resistance of over 10 MΩ. The permissible short-time current is 100 A for 1 second, 120 A for 500 ms, and 140 A for 100 ms, enhancing safety during short-term overloads. The rated switching capacity is 140 A AC and 250 A DC, in accordance with IEC 60947-5-1.

Compatibility and accessories

The LADN02 is compatible with a wide range of contactors from the TeSys D and TeSys F product ranges, including models such as LC1D80ED, LC1D258D7, LC1DT25E7, LC1D80008E7, LC1D258G7, LC1D40AE7, LC1D18B7, LC1D128D7, LC1D098G7, LC1D65ABD, CAD32BD, LC1D25JL, LC1D09ED, LC1D25P7, LC1DT25F7, LC1D150BD, LC1D32SD, LC1D25FC7, and LC1D09GD. Combining it with these contactors extends their functionality by integrating auxiliary contacts.

Mounting and installation

Mounting is performed front-side by snapping onto the respective contactor housing. The screw terminals ensure a secure and reliable connection for the wiring. Installation is carried out under normal ambient conditions, with an operating temperature range between -5 °C and 60 °C. Storage is possible at temperatures from -60 °C to 80 °C. The operating altitude is up to 3,000 m above sea level. The protection rating IP20 according to IEC 60529 protects against finger contact and ingress of solid foreign objects larger than 12.5 mm.

Operational advantages

The LADN02 offers a reliable and low-maintenance solution for extending control systems. Its modular design enables quick installation and reduces mounting time. The high mechanical life and robust construction ensure long-term operation. The screw terminals guarantee a secure and durable connection, even under vibration and mechanical stress. Compatibility with a broad range of contactors increases flexibility in system design.

Standards and certifications

The auxiliary switch block complies with standards EN/IEC 60947-5-1, GB/T 14048.5, EN 50012, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, and UL 60335-2-40:Annex JJ. Product certifications include CB Scheme, UL, CSA, CCC, and EAC. The rated insulation voltage is 690 V (IEC 60947-5-1), 600 V (UL), and 600 V (CSA). The construction conforms to coating class TH according to IEC 60068.

Color and dimensions

The auxiliary switch block has a dark gray color and dimensions of 48 mm (height), 26 mm (width), and 42 mm (depth). Its compact design enables efficient space utilization in enclosures.

Warranty

The warranty period is 18 months.

Protection rating and ambient conditions

The protection rating IP20 protects against finger contact and larger foreign objects. The operating temperature range is between -5 °C and 60 °C, and the storage temperature range is between -60 °C and 80 °C. The operating altitude is up to 3,000 m above sea level.

Connections

Connections are made via screw terminals designed for cable cross-sections of 1 to 4 mm² (flexible and rigid), with or without wire end ferrules. The tightening torque is 1.7 Nm, and installation is performed using a flat-head screwdriver (Ø 6 mm) or a Phillips screwdriver (No. 2).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/993670
qrcode für Schneider Electric LADN02 auxiliary switch block 2NO front