Schneider Electric LA4KC1B, EAN: 3389110230185

Schneider Electric LA4KC1B wiring module 12-24 VDC

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LA4KC1B wiring module 12-24 VDC

Lieske Part No. 104822
Mfg Part No LA4KC1B
EAN-Code 3389110230185
Manufacturer Schneider Electric
Here only 11,69 EUR
13,91 EUR incl. VAT

Further information for Schneider Electric LA4KC1B wiring module 12-24 VDC

Complementary
Mounting locationFront side
Mounting modeClip-on
Suppressor technologyBidirectional peak limiting diode
[Uc] control circuit voltage12...24 V DC
Maximum peak voltage2 Uc
Local signallingLED
Quantity per setSet of 5
Height26 mm
Width6 mm
Depth22 mm
Net weight0.01 kg
Contractual warranty
Warranty (in months)18
Environment
StandardsUL 60947-5-1; CSA C22.2 No 60947-5-1; EN/IEC 60947-5-1
Product certificationsUL; CSA; CE; UKCA
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTC conforming to IEC 60068; TC conforming to DIN 50016
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-50…80 °C
Logistical informations
Country of originID
Main
RangeTeSys
Device short nameLA4K
Product or component typeSuppressor module
Product compatibilityLP1K; LP4K; CA3K
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height0.800 cm
Package 1 Width2.800 cm
Package 1 Length4.200 cm
Package 1 Weight4.000 g
Unit Type of Package 2BB1
Number of Units in Package 25
Package 2 Height2.800 cm
Package 2 Width5.200 cm
Package 2 Length4.300 cm
Package 2 Weight28.000 g
Unit Type of Package 3S01
Number of Units in Package 3420
Package 3 Height15.000 cm
Package 3 Width15.000 cm
Package 3 Length40.000 cm
Package 3 Weight2.657 kg
The surge suppression module LA4KC1B from Schneider Electric belongs to the TeSys series and serves as an overvoltage limiter for control circuits. It is specifically designed for use with small contactors of types LP1K, LP4K, and CA3K to suppress electrical interference and voltage spikes in the control circuit. The module is mounted by clipping onto the front of the contactor and is thus directly integrated into the existing control system. The bidirectional amplitude limiter diode ensures that voltage spikes, which can reach up to twice the control circuit voltage (2 Uc), are diverted to protect sensitive control components.

Applications
This surge suppression module is intended for industrial applications where electrical interference may occur due to switching operations or external influences. It is particularly used in systems with frequent switching operations, such as motor drives, pumps, or fans, to enhance the reliability of control systems. Compatibility with contactor types LP1K, LP4K, and CA3K allows for flexible use in various switching configurations.

Functions and Features in Detail
The module operates with a control circuit voltage of 12 to 24 V DC and is thus suitable for common low-voltage control systems. Local signaling is provided by an LED, which visually indicates the operating status. Mounting is done by clipping onto the front of the contactor, requiring no additional drilling or mounting aids. The compact design, with a height of 26 mm, width of 6 mm, and depth of 22 mm, allows for space-saving installation.

Technology Explained Simply
The bidirectional amplitude limiter diode responds to voltage spikes in both directions and limits them to a safe level. This protects control electronics from damage caused by transient overvoltages, which may occur during switching operations or due to external interference sources. The maximum peak voltage the module can handle is twice the control circuit voltage (2 Uc), providing sufficient protection for typical applications. The LED signaling allows for quick visual inspection of the operating status without requiring additional measuring instruments.

Compatibility and Accessories
The surge suppression module LA4KC1B is specifically designed for use with contactor types LP1K, LP4K, and CA3K. It can be combined with various power contactors and auxiliary contactors from the TeSys-K series, such as LP1K090045BD, LP1K0901JD, or CA3KN313BD. Combining it with these contactors enables optimal protection for control circuits in industrial installations.

Mounting and Installation
Mounting is simple and quick, achieved by clipping onto the front of the contactor. No additional tools or mounting aids are required. Front-side mounting allows direct integration into existing control systems without additional space requirements. The protection rating IP2x according to IEC 60529 provides protection against contact with fingers and larger objects, but not against dust or water. The operating ambient temperature ranges from -25 °C to 50 °C, enabling use in typical industrial environments.

Operational Advantages
The integrated overvoltage limitation extends the service life of control electronics and increases operational safety. The LED signaling enables quick fault diagnosis. The compact design and easy mounting reduce installation time and costs. Certifications including UL, CSA, CE, and UKCA, along with compliance with EN/IEC 60947-5-1 standards, ensure safe and reliable performance in various markets. The protection treatment TC according to IEC 60068 and DIN 50016 ensures long-term stability of the module under industrial conditions.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/104822
qrcode für Schneider Electric LA4KC1B wiring module 12-24 VDC