| Complementary |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Slip-on terminals |
| Reset time | 1.5 s during time delay; 0.5 s after time delay |
| Height | 27 mm |
| Width | 38 mm |
| Depth | 38 mm |
| Net weight | 0.04 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TC conforming to IEC 60068 |
| Ambient air temperature for operation | -10…60 °C |
| Logistical informations |
| Country of origin | TN |
| Main |
| Range | TeSys |
| Product name | TeSys K |
| Product or component type | Time delay auxiliary contact block |
| Device short name | LA1 |
| Range compatibility | TeSys K LC1K; TeSys K CA2K; TeSys K CA3K; TeSys K CA4K |
| Mounting location | Front |
| Pole contact composition | 1 C/O |
| Contacts operation | Time delay |
| Timer type | On delay |
| Time delay range | 1...30 s |
| [Ue] rated operational voltage | 110...240 V AC for control circuit; 240 V AC for signalling circuit |
| Rated operational voltage limits | 0.85...1.1 Uc |
| [Ith] conventional free air thermal current | 2 A for signalling circuit |
| Standards | EN/IEC 60947-5-1 |
| Product certifications | CE; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.000 cm |
| Package 1 Width | 4.800 cm |
| Package 1 Length | 4.800 cm |
| Package 1 Weight | 44.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 70 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 3.361 kg |
The auxiliary switch block LA2KT2U from the TeSys K series by Schneider Electric is a time-delayed auxiliary switch block specifically designed for integration into control and signal circuits of small contactors. It serves as an add-on component to extend the functionality of power contactors and reversing contactor combinations in the TeSys K series, particularly for applications requiring a time delay in switching operations. The switch block is designed for mounting on the front side of main devices, enabling seamless integration into existing installations. Compatibility includes the product families TeSys K LC1K, CA2K, CA3K, and CA4K.
Applications
The LA2KT2U is used in industrial control systems where controlled delay during switching operations is required. Typical applications include delaying motor start-up, synchronizing switching operations in complex systems, or avoiding short-circuit currents through time-shifted switching. The time delay occurs during switching-on and ranges from 1 to 30 seconds, allowing flexible adaptation to different process requirements.
Functions and Features in Detail
The switch block features a changeover contact (1S+1Oe) serving as an auxiliary contact and usable in control or signal circuits. The time delay is achieved via an integrated mechanism enabling switching-on delay. The reset time is 1.5 seconds during the delay phase and 0.5 seconds after the delay ends, ensuring a quick response once the delay period is over. Connections are made via push-in terminals, enabling easy and secure wiring.
Technology Explained Simply
The rated operational voltage is 110 to 240 V AC for control circuits and 240 V AC for signal circuits. The rated operational voltage range is between 0.85 and 1.1 times the nominal voltage, enabling stable operation under slightly fluctuating voltage conditions. The conventional thermal current is 2 A for signal circuits, defining the contact load capacity. The insulation resistance is greater than 10 MΩ, ensuring high electrical insulation and safety. The protection rating IP20 corresponds to IEC 60529 and protects against finger contact and solid foreign objects, but not against water or dust. The operating ambient temperature ranges from -10 °C to 60 °C, allowing use in normal industrial environments. The TC coating conforms to IEC 60068 and ensures sufficient corrosion protection.
Compatibility and Accessories
The LA2KT2U is specifically developed for use with products from the TeSys K series, including power contactors such as LC1K0610G7, LC1K1210F7, LC2K1210F7, and reversing contactor combinations such as LC2K0910U7. Combining it with these devices enables extending control functions with time-delayed switching. Use with auxiliary contactors such as CA2KN31E7 or CA4KN22EW3 is also possible, provided mounting compatibility is ensured.
Mounting and Installation
Mounting is performed on the front side of main devices, with dimensions of 38 mm width, 27 mm height, and 38 mm depth enabling compact placement. The push-in terminals allow quick and secure wiring without additional tools. Installation is carried out under normal environmental conditions, with operating temperatures between -10 °C and 60 °C.
Operational Advantages
Using the LA2KT2U enables precise control of switching operations through integrated switching-on delay. Combination with TeSys K devices ensures high compatibility and reliability. The robust construction, weighing 0.04 kg and with compact dimensions, ensures efficient integration into existing installations. Certifications CE and UKCA, along with standard EN/IEC 60947-5-1, guarantee compliance with European safety and quality standards. The warranty period is 18 months, underscoring the product’s reliability.