Insulation resistance> 10 MOhm
Connections - terminalsSlip-on terminals
Reset time1.5 s during time delay; 0.5 s after time delay
Height27 mm
Width38 mm
Depth38 mm
Net weight0.04 kg
Contractual warranty
Warranty (in months)18
Environment
Environmental characteristicNormal environment
IP degree of protectionIP20 conforming to IEC 60529
Protective treatmentTC conforming to IEC 60068
Ambient air temperature for operation-10…60 °C
Logistical informations
Country of originTN
Main
RangeTeSys
Product nameTeSys K
Product or component typeTime delay auxiliary contact block
Device short nameLA1
Range compatibilityTeSys K LC1K; TeSys K CA2K; TeSys K CA3K; TeSys K CA4K
Mounting locationFront
Pole contact composition1 C/O
Contacts operationTime delay
Timer typeOn delay
Time delay range1...30 s
[Ue] rated operational voltage110...240 V AC for control circuit; 240 V AC for signalling circuit
Rated operational voltage limits0.85...1.1 Uc
[Ith] conventional free air thermal current2 A for signalling circuit
StandardsEN/IEC 60947-5-1
Product certificationsCE; UKCA
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width4.800 cm
Package 1 Length4.800 cm
Package 1 Weight44.000 g
Unit Type of Package 2S02
Number of Units in Package 270
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight3.361 kg
The auxiliary switch block LA2KT2U from the TeSys K series by Schneider Electric is a time-delayed auxiliary switch block specifically designed for integration into control and signal circuits of small contactors. It serves as an add-on component to extend the functionality of power contactors and reversing contactor combinations in the TeSys K series, particularly for applications requiring a time delay in switching operations. The switch block is designed for mounting on the front side of main devices, enabling seamless integration into existing installations. Compatibility includes the product families TeSys K LC1K, CA2K, CA3K, and CA4K.

Applications

The LA2KT2U is used in industrial control systems where controlled delay during switching operations is required. Typical applications include delaying motor start-up, synchronizing switching operations in complex systems, or avoiding short-circuit currents through time-shifted switching. The time delay occurs during switching-on and ranges from 1 to 30 seconds, allowing flexible adaptation to different process requirements.

Functions and Features in Detail

The switch block features a changeover contact (1S+1Oe) serving as an auxiliary contact and usable in control or signal circuits. The time delay is achieved via an integrated mechanism enabling switching-on delay. The reset time is 1.5 seconds during the delay phase and 0.5 seconds after the delay ends, ensuring a quick response once the delay period is over. Connections are made via push-in terminals, enabling easy and secure wiring.

Technology Explained Simply

The rated operational voltage is 110 to 240 V AC for control circuits and 240 V AC for signal circuits. The rated operational voltage range is between 0.85 and 1.1 times the nominal voltage, enabling stable operation under slightly fluctuating voltage conditions. The conventional thermal current is 2 A for signal circuits, defining the contact load capacity. The insulation resistance is greater than 10 MΩ, ensuring high electrical insulation and safety. The protection rating IP20 corresponds to IEC 60529 and protects against finger contact and solid foreign objects, but not against water or dust. The operating ambient temperature ranges from -10 °C to 60 °C, allowing use in normal industrial environments. The TC coating conforms to IEC 60068 and ensures sufficient corrosion protection.

Compatibility and Accessories

The LA2KT2U is specifically developed for use with products from the TeSys K series, including power contactors such as LC1K0610G7, LC1K1210F7, LC2K1210F7, and reversing contactor combinations such as LC2K0910U7. Combining it with these devices enables extending control functions with time-delayed switching. Use with auxiliary contactors such as CA2KN31E7 or CA4KN22EW3 is also possible, provided mounting compatibility is ensured.

Mounting and Installation

Mounting is performed on the front side of main devices, with dimensions of 38 mm width, 27 mm height, and 38 mm depth enabling compact placement. The push-in terminals allow quick and secure wiring without additional tools. Installation is carried out under normal environmental conditions, with operating temperatures between -10 °C and 60 °C.

Operational Advantages

Using the LA2KT2U enables precise control of switching operations through integrated switching-on delay. Combination with TeSys K devices ensures high compatibility and reliability. The robust construction, weighing 0.04 kg and with compact dimensions, ensures efficient integration into existing installations. Certifications CE and UKCA, along with standard EN/IEC 60947-5-1, guarantee compliance with European safety and quality standards. The warranty period is 18 months, underscoring the product’s reliability.