| Complementary |
| Mounting location | Front side |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947; 690 V conforming to BS 5424; 690 V conforming to VDE 0110 group C; 690 V conforming to CSA C22.2 No 14 |
| [Ue] rated operational voltage | 690 V AC |
| [Ith] conventional free air thermal current | 10 A (at 55 °C) |
| Associated fuse rating | 10 A gL conforming to IEC 60947; 10 A gL conforming to VDE 0660 |
| Tightening torque | 0.8 N.m - on screw clamp terminals |
| Width | 27 mm |
| Net weight | 0.022 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 60947-5-1; EN/IEC 60947-5-1; UL 60947-5-1 |
| Product certifications | CB Scheme; CE; UKCA; EAC; cULus |
| IP degree of protection | IP2X |
| Protective treatment | TC conforming to IEC 60068 |
| Ambient air temperature for operation | -20…50 °C |
| Ambient air temperature for storage | -50…70 °C |
| Operating altitude | 2000 m without derating |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys |
| Device short name | LA1SK |
| Product or component type | Auxiliary contact block |
| Product compatibility | LC1SK |
| Auxiliary contacts operation | Instantaneous |
| Pole contact composition | 2 NO |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…6 mm²solid; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.5…6 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 0.35…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 0.35…6 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.35…1.5 mm²flexible without cable end |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.500 cm |
| Package 1 Width | 4.000 cm |
| Package 1 Length | 5.000 cm |
| Package 1 Weight | 27.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 60 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 1.774 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 1920 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 60.000 cm |
| Package 3 Weight | 64.768 kg |
The auxiliary switch block LA1SK20 from Schneider Electric belongs to the TeSys series and serves as an add-on component for mini contactors of the LC1SK series. It is specifically designed for integration into compact control systems covering up to 2.2 kW power at AC-3 operation. The device enables space-saving installation, as five TeSys SK mini contactors can replace three conventional contactors. The auxiliary switch block features two
closing contacts (2S) that operate without delay, making them suitable for fast signal transmission in control and protection circuits.
Applications
The LA1SK20 is used in industrial installations where compact design and reliable auxiliary functions are required. It is ideal for applications in automation technology, such as motor, pump, or fan control, where additional contacts are needed for status indication, feedback to control devices, or for interlocking switching operations. Its use in control systems with limited space, such as enclosures or mobile equipment, is particularly advantageous due to its narrow width of 27 mm.
Functions and Equipment in Detail
The auxiliary switch block is equipped with
screw terminals suitable for various cable types: rigid cables from 1.5 to 6 mm², flexible cables from 0.35 to 6 mm² (with or without wire end ferrules). The terminals require a
tightening torque of 0.8 Nm to ensure a secure and durable connection. The contacts are rated for an
operating voltage of 690 V AC, enabling use in industrial networks with high voltage. The
rated insulation voltage is also 690 V, in accordance with standards IEC 60947, BS 5424, VDE 0110 Group C, and CSA C22.2 No. 14.
Technology Explained Simply
The auxiliary switch block operates without delay, meaning the contacts switch immediately upon actuation of the main contact. This is important for applications requiring fast feedback or control. The
thermal rated current (Ith) is 10 A at an ambient temperature of 55 °C, defining the device's load capacity under normal operating conditions. The associated fuse is specified as 10 A gL to ensure safety in case of fault. The
protection class IP2x protects against finger contact and solid objects larger than 12.5 mm, but not against water or dust — therefore, installation is exclusively indoors, preferably on the front side of the control device.
Compatibility and Accessories
The LA1SK20 is specifically designed for use with mini contactors from the LC1SK series. It can be combined with various power contactors such as LC1SK0600U7, LC1SK0600P7, LC1SK0600B7, or LC1SK0600F7 to extend the functionality of the control system. Additionally, auxiliary contactors such as CA2SK20P7, CA2SK20D7, CA2SK20U7, CA2SK20B7, CA2SK20E7, CA2SK20F7, and CA2SK20G7 are available, which can be integrated into the system depending on the operating voltage (e.g., 24 V, 230 V, 48 V, 110 V, 120 V). Combining these components enables a flexible and modular design of control systems.
Mounting and Installation
Mounting is done on the front side of the control device, with the screw terminals connected directly to the cables. The specified tightening torque of 0.8 Nm must be observed to ensure a reliable electrical connection. The operating temperature range is from -20 °C to 50 °C, and the storage temperature range is from -50 °C to 70 °C. The device can be used up to an operating altitude of 2,000 m without performance reduction. The coating complies with the TC standard according to IEC 60068, ensuring high corrosion resistance and durability under industrial conditions.
Advantages in Operation
The LA1SK20 offers high functionality with minimal height. Combined with LC1SK contactors, it enables a compact and efficient control system that saves space while providing necessary auxiliary functions. Certifications according to EN/IEC 60947-5-1, CSA C22.2 No. 60947-5-1, and UL 60947-5-1, as well as product certifications CE, UKCA, EAC, and cULus, guarantee compliance with international safety and quality standards. The warranty period is 18 months, underscoring the product's reliability.