| Complementary |
| Mounting location | Front side |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947; 690 V conforming to BS 5424; 690 V conforming to VDE 0110 group C; 690 V conforming to CSA C22.2 No 14 |
| [Ue] rated operational voltage | 690 V AC |
| [Ith] conventional free air thermal current | 10 A (at 55 °C) |
| Associated fuse rating | 10 A gL conforming to IEC 60947; 10 A gL conforming to VDE 0660 |
| Tightening torque | 0.8 N.m - on screw clamp terminals |
| Width | 27 mm |
| Net weight | 0.022 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | CSA C22.2 No 60947-5-1; EN/IEC 60947-5-1; UL 60947-5-1 |
| Product certifications | CB Scheme; CE; UKCA; EAC; cULus |
| IP degree of protection | IP2X |
| Protective treatment | TC conforming to IEC 60068 |
| Ambient air temperature for operation | -20…50 °C |
| Ambient air temperature for storage | -50…70 °C |
| Operating altitude | 2000 m without derating |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys |
| Device short name | LA1SK |
| Product or component type | Auxiliary contact block |
| Product compatibility | LC1SK |
| Auxiliary contacts operation | Instantaneous |
| Pole contact composition | 2 NC |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…6 mm²solid; Screw clamp terminals 2 cable(s) 1.5…4 mm²solid; Screw clamp terminals 1 cable(s) 0.5…6 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 0.35…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 0.35…6 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.35…1.5 mm²flexible without cable end |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.600 cm |
| Package 1 Width | 5.300 cm |
| Package 1 Length | 4.200 cm |
| Package 1 Weight | 29.000 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 60 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 15.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 1.854 kg |
The auxiliary switch block LA1SK02 from Schneider Electric belongs to the TeSys series and serves as an add-on component for the mini contactors of the LC1SK series. It is specifically designed for use in compact control panels, where space-saving and modular expandability are prioritized. The block features two normally open contacts (2NO) and thus enables control or signal transmission in electrical circuits. The actuation of the auxiliary contacts is instantaneous, making it suitable for applications requiring direct switching logic.
Applications
The LA1SK02 is used in industrial and commercial installations where small contactors up to 2.2 kW power (AC-3) are employed. It is ideal for systems where multiple switching functions must be integrated into a limited space. The modular design of the TeSys SK series allows five mini contactors to be mounted in place of three conventional contactors, making control panel design more efficient. The auxiliary switch block is suitable for use in control systems, drive technology, and machine building, particularly when additional signals or feedback are required via auxiliary contacts.
Functions and Equipment in Detail
The LA1SK02 features screw terminals for cable connections. The terminals are designed for various cable cross-sections: rigid cables from 1.5 to 6 mm² (one cable) or 1.5 to 4 mm² (two cables), and flexible cables with wire end ferrules from 0.5 to 6 mm² (one cable) or 0.35 to 2.5 mm² (two cables). Flexible cables without wire end ferrules can also be connected, with cross-sections of 0.35 to 6 mm² (one cable) or 0.35 to 1.5 mm² (two cables). The tightening torque for the screw terminals is 0.8 Nm. The contacts are configured as normally open, meaning they are open in the resting state and close when the contactor is actuated.
Technology Explained Simply
The auxiliary switch block is rated for an operating voltage of 690 V AC, making it suitable for a wide range of industrial applications. The rated insulation voltage is also 690 V and complies with international standards such as IEC 60947, BS 5424, VDE 0110 Group C, and CSA C22.2 No. 14. The conventional thermal current (Ith) is 10 A at an ambient temperature of 55 °C, defining the device’s load capacity under realistic operating conditions. The associated fuse is specified as 10 A GL, indicating the required protection for the connecting lines. The protection class IP2x protects against finger contact and larger solid objects, but not against water or dust — therefore, the device is intended for indoor use only.
Compatibility and Accessories
The LA1SK02 is specifically designed for mounting on LC1SK contactors. It is mounted on the front side of the main device and extends its functionality with additional auxiliary contacts. Compatible devices from the TeSys SK program include, for example, power contactors LC1SK0600F7, LC1SK0600P7, LC1SK0600B7, and LC1SK0600U7, as well as auxiliary contactors such as CA2SK20D7, CA2SK20F7, CA2SK20P7, CA2SK20G7, CA2SK20E7, CA2SK20U7, and CA2SK20B7. These can be combined according to requirements in the control panel to realize complex control logic.
Mounting and Installation
Mounting is performed on the front side of the LC1SK contactor. The width of the auxiliary switch block is 27 mm, enabling modular integration into standard control panels. The operating ambient temperature ranges from -20 °C to 50 °C, while the storage temperature ranges from -50 °C to 70 °C. The operating altitude is up to 2,000 m without performance reduction. The coating complies with IEC 60068 (TC), ensuring resistance to environmental influences such as humidity and temperature fluctuations. Mounting requires no additional tools, as the screw terminals are directly secured at the connection points of the contactor.
Advantages in Operation
The LA1SK02 offers a compact and reliable solution for expanding control panels. The modular design of the TeSys SK series enables efficient use of available space. The use of auxiliary contacts reduces the need for additional switches or relays, simplifying the circuit and reducing error rates. The high operational safety at a rated voltage of 690 V AC and compliance with international standards such as EN/IEC 60947-5-1, CSA C22.2 No. 60947-5-1, and UL 60947-5-1 ensures safe and standard-compliant integration into industrial installations. Certifications including CB Regulation, CE, UKCA, EAC, and cULus confirm compliance with applicable safety and quality requirements.