Schneider Electric LA1KN22, EAN: 3389110500110

Schneider Electric LA1KN22 Auxiliary Switch 2S+2NO

Industrial Material > Industrial relays and contactors > Contactors

Schneider Electric LA1KN22 Auxiliary Switch 2S+2NO

Lieske Part No. 654243
Mfg Part No LA1KN22
EAN-Code 3389110500110
Manufacturer Schneider Electric
Here only 18,48 EUR
21,99 EUR incl. VAT

Further information for Schneider Electric LA1KN22 Auxiliary Switch 2S+2NO

Complementary
Irms rated making capacity110 A at
Permissible short-time rating80 A 1 s; 60 A 500 ms; 110 A 100 ms
Associated fuse rating10 A gG at
Minimum switching current5 mA
Minimum switching voltage17 V
Non overlap distance0.5 mm
Insulation resistance> 10 MOhm
Connections - terminalsScrew clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1.5…4 mm²rigid; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²rigid
Tightening torque1.3 N.m - with screwdriver Philips No 2; 1.3 N.m - with screwdriver pozidriv No 2
Height30 mm
Width38 mm
Depth35 mm
Net weight0.045 kg
Contractual warranty
Warranty (in months)18
Environment
Environmental characteristicNormal environment
IP degree of protectionIP20 conforming to IEC 60529
Protective treatmentTC conforming to IEC 60068
Ambient air temperature for storage-50…80 °C
Ambient air temperature for operation-25…50 °C
Operating altitude2000 m
Logistical informations
Country of originID
Main
RangeTeSys
Product nameTeSys K
Product or component typeAuxiliary contact block
Device short nameLA1
Range compatibilityTeSys K LC1K; TeSys K CA2K; TeSys K CA3K
Mounting locationFront
Pole contact composition2 NO + 2 NC
Contacts operationInstantaneous
[Ue] rated operational voltage690 V AC 25...400 Hz
[Ui] rated insulation voltage690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1
[Ith] conventional free air thermal current10 A (at 50 °C)
StandardsEN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; JIS C8201-5-1; UL 60335-2-40:Annex JJ
Product certificationsCB Scheme; CCC; UL; CSA; CE; UKCA
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.000 cm
Package 1 Width4.500 cm
Package 1 Length6.000 cm
Package 1 Weight41.000 g
Unit Type of Package 2S02
Number of Units in Package 2100
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight4.729 kg
Unit Type of Package 3P06
Number of Units in Package 31600
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight81.060 kg
The auxiliary switch block LA1KN22 from the TeSys K series by Schneider Electric is an instantaneous auxiliary contact module specifically designed for front mounting on contactors of the TeSys K series (LC1K, CA2K, CA3K). It serves to extend control functions in industrial systems by providing additional switching contacts for signals, feedback, or logic control. The module features a contact configuration of 2 S + 2 Ö (2 normally closed and 2 normally open contacts), suitable for flexible switching configurations in control systems. The contacts are instantaneous, meaning they switch directly and without delay upon actuation of the main contact.

Applications
The auxiliary switch block is used in industrial control systems where additional contacts are required for monitoring operating states, triggering alarms, or controlling other components. It is compatible with contactor series LC1K, CA2K, and CA3K, which are widely used in automation technology, machine building, and manufacturing. Front mounting allows for easy integration into existing control systems without additional mounting components.

Functions and Equipment in Detail
The device is equipped with screw terminals suitable for connecting cables with cross-sections from 0.34 to 4 mm². The terminals support both flexible and rigid conductors, with different connection options provided for flexible conductors with and without wire end ferrules. The tightening torque is 1.3 Nm, and installation is performed using a Phillips screwdriver No. 2 or position No. 2. The contacts are rated for an operating voltage of 690 V AC (25–400 Hz), enabling use in high-voltage systems up to 690 V. The rated insulation voltage is 690 V according to IEC 60947-5-1, ensuring high electrical safety.

Technology Explained Simply
The auxiliary switch block is designed for a thermal rating of 10 A at 50 °C in free air, making it suitable for continuous operation in industrial environments. The rated switching capacity is 110 A, indicating the device’s ability to handle short-term current surges during switching operations. The permissible short-time current is defined as 80 A for 1 second, 60 A for 500 ms, and 110 A for 100 ms, highlighting its robustness under transient loads. The minimum switching voltage is 17 V and the minimum switching current is 5 mA, enabling reliable switching even with low-level signals. The insulation resistance is greater than 10 MΩ, ensuring high electrical insulation and safety.

Compatibility and Accessories
The auxiliary switch block is specifically developed for use with contactor series LC1K, CA2K, and CA3K from the TeSys K series. It can be combined with various power contactors and reversing contactor combinations to extend control functions. Compatible products include, for example, power contactors LC1K0610U7, LC1K0901U7, or LC2K06105B7, as well as auxiliary contactors such as CA2KN31B7 or CA3KN22MD3. Combining these devices enables a flexible and modular design of control systems.

Mounting and Installation
Mounting is performed on the front side of the contactor, with the module secured by snap-in. Dimensions are 38 mm (width), 30 mm (height), and 35 mm (depth), enabling compact integration into enclosures. The protection rating IP20 according to IEC 60529 protects against finger contact and ingress of solid foreign objects larger than 12.5 mm, but does not protect against water or dust. The operating temperature range is from -25 °C to 50 °C, and the storage temperature range is from -50 °C to 80 °C. The maximum operating altitude is 2,000 m above sea level.

Operational Advantages
The auxiliary switch block provides a reliable and maintenance-friendly solution for extending control functions. The screw terminals allow for secure and easy wiring, while the high insulation strength and thermal rating ensure long service life and safe operation. Compatibility with the TeSys K series enables modular expansion of existing systems without additional mounting components. Certifications according to EN/IEC 60947-5-1, UL, CSA, CE, and UKCA ensure compliance with international safety and quality standards.

Standards and Certifications
The device complies with standards EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5, JIS C8201-5-1, as well as UL 60335-2-40:Annex JJ. Product certifications include CB Scheme, CCC, UL, CSA, CE, and UKCA, confirming international usability and safety. The coating corresponds to category TC according to IEC 60068, ensuring high resistance to environmental influences.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/654243