| Complementary |
| Irms rated making capacity | 110 A at |
| Permissible short-time rating | 80 A 1 s; 60 A 500 ms; 110 A 100 ms |
| Associated fuse rating | 10 A gG at |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non overlap distance | 0.5 mm |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Screw clamp terminals 1 cable(s) 0.34…1.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1.5…4 mm²rigid; Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1.5…4 mm²rigid |
| Tightening torque | 1.3 N.m - with screwdriver Philips No 2; 1.3 N.m - with screwdriver pozidriv No 2 |
| Height | 30 mm |
| Width | 38 mm |
| Depth | 35 mm |
| Net weight | 0.045 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Protective treatment | TC conforming to IEC 60068 |
| Ambient air temperature for storage | -50…80 °C |
| Ambient air temperature for operation | -25…50 °C |
| Operating altitude | 2000 m |
| Logistical informations |
| Country of origin | ID |
| Main |
| Range | TeSys |
| Product name | TeSys K |
| Product or component type | Auxiliary contact block |
| Device short name | LA1 |
| Range compatibility | TeSys K LC1K; TeSys K CA2K; TeSys K CA3K; TeSys K CA4K |
| Mounting location | Front |
| Pole contact composition | 2 NO |
| Contacts operation | Instantaneous |
| [Ue] rated operational voltage | 690 V AC 25...400 Hz |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A (at 50 °C) |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; JIS C8201-5-1; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CCC; UL; CSA; CE; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.700 cm |
| Package 1 Width | 4.000 cm |
| Package 1 Length | 4.000 cm |
| Package 1 Weight | 31.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 5.000 cm |
| Package 2 Width | 17.000 cm |
| Package 2 Length | 17.000 cm |
| Package 2 Weight | 317.000 g |
| Unit Type of Package 3 | S02 |
| Number of Units in Package 3 | 100 |
| Package 3 Height | 15.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 3.800 kg |
The auxiliary switch block LA1KN20 from the TeSys K series by Schneider Electric is a compact, front-mountable add-on module for small contactors. It serves as an auxiliary contact module to extend the switching functions of TeSys K contactors such as LC1K, CA2K, CA3K, and CA4K. The block features two normally open contacts (2S) and thus enables the control of additional switching operations, for example for signal lamps, relays or other control components. The contacts switch without delay, which is required for applications with direct signal transmission.
Applications
The auxiliary switch block is designed for industrial control systems where an extension of the switching functions of small contactors is required. It is frequently used in plants for controlling motors, pumps, fans or other electrical consumers, where additional signals or feedback are needed. Integration takes place directly on the front side of the main contactor, thereby minimizing space requirements in the enclosure.
Functions and equipment in detail
The LA1KN20 features two normally open contacts suitable for transmitting switching states. The contacts are rated for an operating voltage of 690 V AC (25–400 Hz) and can carry a conventional thermal current of 10 A at 50 °C in free air. The minimum switching voltage is 17 V, and the minimum switching current is 5 mA, enabling use even with low loads. The permissible short-time current is 80 A for 1 second, 60 A for 500 ms, and 110 A for 100 ms, highlighting robustness under short-term load peaks.
Technology explained simply
The screw terminals of the auxiliary switch block allow connection with cables in cross-sections from 0.34 to 4 mm², supporting flexible cables with or without cable ends, as well as rigid cables. The tightening torque is 1.3 Nm, using a Phillips screwdriver No. 2 or position No. 2. The insulation class corresponds to IP20 according to IEC 60529, providing protection against finger contact and against solid foreign objects. The rated insulation voltage is 690 V (IEC 60947-5-1), 600 V (UL 60947-5-1), and 600 V (CSA C22.2 No. 60947-5-1), enabling use in various international standard regions.
Compatibility and accessories
The auxiliary switch block is specifically developed for the TeSys K contactor series, including models LC1K, CA2K, CA3K, and CA4K. It can be combined with various power contactors, for example LC1K090085P7 or LC1K09008U7, to extend switching functions. The associated fuse rating is 10 A gG, ensuring safety in case of overloads.
Mounting and installation
Mounting is performed on the front side of the main contactor, with the auxiliary switch block dimensions being 38 mm (width), 30 mm (height), and 35 mm (depth). The operating temperature ranges from -25 °C to 50 °C, and the storage temperature from -50 °C to 80 °C. The maximum operating altitude is 2,000 m above sea level. The coating corresponds to the TC class according to IEC 60068, ensuring resistance to environmental influences.
Advantages in operation
The auxiliary switch block offers a compact and reliable solution for extending the switching functions of small contactors. The screw terminals enable secure and easy wiring, while the high insulation strength and robust construction ensure reliability in industrial environments. Integration into existing TeSys K systems requires no additional mounting components, speeding up installation and reducing space requirements in the enclosure. Compliance with standards EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1 and other international standards ensures use in various markets.
Product certifications include CB Regulation, CCC, UL, CSA, CE, and UKCA, confirming compliance with relevant safety and quality standards. The product weight is 0.045 kg, facilitating handling and installation. The warranty period is 18 months.