| Complementary |
| Protection type | GG fuse 10 A for non-protected contact |
| Mechanical durability | 5 Mcycles |
| Minimum switching current | 1 mA for protected contact; 5 mA for non-protected contact |
| Minimum switching voltage | 5 V for protected contact; 17 V for non-protected contact |
| Insulation resistance | > 10 MOhm |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid; Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid |
| Tightening torque | 1.7 N.m - with screwdriver flat Ø 6 mm; 1.7 N.m - with screwdriver Philips No 2; 1.7 N.m - with screwdriver pozidriv No 2 |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 39 mm |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Environmental characteristic | Harsh environment |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for storage | -25…70 °C |
| Ambient air temperature for operation | -25…70 °C |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys |
| Product name | TeSys Deca |
| Product or component type | Auxiliary contact block |
| Device short name | LA1 |
| Range compatibility | TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D |
| Mounting location | Front |
| Pole contact composition | 2 NO (sealed) + 1 NO + 1 NC |
| Contacts operation | Instantaneous |
| [Ue] rated operational voltage | 125 V AC for protected contact; 30 V DC for protected contact; 690 V AC for non-protected contact |
| [Ie] rated operational current | 0.1 A for protected contact |
| [Ui] rated insulation voltage | 250 V - for protected contact conforming to IEC 60947-5-1; 690 V - for non-protected contact conforming to IEC 60947-5-1; 600 V - for non-protected contact conforming to UL 60947-5-1; 600 V - for non-protected contact conforming to CSA C22.2 No 60947-5-1 |
| [Ith] conventional free air thermal current | 10 A (at 40 °C) for non-protected contact |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5 |
| Product certifications | CB; UL; CSA; CCC; EAC; UKCA |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.700 cm |
| Package 1 Width | 4.800 cm |
| Package 1 Length | 5.200 cm |
| Package 1 Weight | 64.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 80 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.463 kg |
The auxiliary switch block LA1DZ31 from Schneider Electric belongs to the TeSys series and is designed as TeSys Deca. It is an undelayed auxiliary switch block specifically designed for mounting on contactors from the product families TeSys D CAD, TeSys D LC1D, TeSys F LC1F, TeSys F CR1F, TeSys Deca CAD, and TeSys Deca LC1D. Mounting is done on the front side of the contactor, with simple snap-in installation enabling quick and secure installation. The block is designed for use in harsh environmental conditions and offers high reliability and durability.
Applications
The auxiliary switch block is used in industrial plants where additional switching functions are required for control and monitoring tasks. It is used, for example, for signal transmission, actuation of auxiliary devices, or feedback of the contactor status to control systems. The combination of protected and unprotected contacts allows flexible adaptation to different requirements in plant engineering.
Functions and Equipment in Detail
The block features a contact configuration of 2 S (encapsulated) + 1 S + 1 Oe. The two encapsulated closing contacts (S) are dust- and moisture-protected and suitable for applications with low rated operational voltage. The rated operational voltage is 125 V AC and 30 V DC. The two additional contacts (1 S + 1 Oe) are unprotected and can be operated up to 690 V AC with a rated operational current of 0.1 A. The mechanical life is 5 million switching cycles, ensuring long service life under industrial conditions.
Technology Explained Simply
The encapsulated contacts offer enhanced protection against dust and moisture, which is particularly beneficial in humid or dusty environments. The unprotected contacts are designed for higher voltages and meet the requirements for rated insulation voltage according to IEC 60947-5-1 (690 V AC) as well as UL 60947-5-1 and CSA C22.2 No. 60947-5-1 (600 V AC). The conventional thermal current is 10 A at 40 °C, describing the thermal load capacity under operating conditions. The minimum switching voltage is 5 V for protected and 17 V for unprotected contacts, with minimum switching currents of 1 mA and 5 mA respectively. The insulation resistance is greater than 10 MΩ, ensuring high electrical insulation.
Compatibility and Accessories
The auxiliary switch block is compatible with the mentioned contactor product families from TeSys D and TeSys F. It can be combined with other auxiliary contactors from the TeSys series, such as models CAD32SD, CAD32E7, CAD32Q7, CAD50GD, CAD50L7, CAD50Q7, CAD32MD, CAD32GD, CAD32G7, CAD50SD, CAD32L7, CAD32D7, CAD50ED, CAD32M7, CAD50E7, CAD32T7, CAD32X7, CAD32UD, CAD32FD, CAD32B7. These models offer different contact configurations and operating voltages, allowing precise adaptation to specific applications.
Mounting and Installation
Mounting is done on the front side of the contactor by snap-in. Connections are made via screw terminals designed for cable cross-sections of 1 to 2.5 mm² flexible (with and without wire end ferrules) and 1 to 2.5 mm² rigid. The required tightening torque is 1.7 Nm, and mounting can be done using a flathead screwdriver (Ø 6), a Phillips screwdriver No. 2, or a positioning screwdriver No. 2. The dimensions of the block are 48 mm height, 44 mm width, and 39 mm depth.
Operational Advantages
The auxiliary switch block offers high mechanical life, secure and easy mounting, and flexible use through the combination of protected and unprotected contacts. Compliance with international standards such as EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, and GB/T 14048.5, as well as certifications CB, UL, CSA, CCC, EAC, and UKCA, ensures reliability and worldwide use. The protection class IP2x according to IEC 60529 protects against finger contact and provides basic protection against solid objects. The coating corresponds to category TH according to IEC 60068, ensuring resistance to environmental conditions such as temperature and humidity. The operating temperature range is between -25 °C and +70 °C, as is the storage temperature.
Standards and Certifications
The auxiliary switch block complies with standards EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, and GB/T 14048.5. Product certifications include CB, UL, CSA, CCC, EAC, and UKCA. RoHS and REACH compliance is also given, confirming environmental compatibility and the use of non-hazardous materials.