| Complementary |
| Transmission rate | 9.6, 19.2 and 38.4 kbauds |
| Mounting support | Flange |
| Motor flange size | 57 mm |
| Number of motor stacks | 2 |
| Centring collar diameter | 38.1 mm |
| Centring collar depth | 1.6 mm |
| Number of mounting holes | 4 |
| Mounting holes diameter | 5.2 mm |
| Circle diameter of the mounting holes | 66.6 mm |
| Feedback type | Index pulse |
| Shaft end | Untapped |
| Second shaft | Without second shaft end |
| Shaft diameter | 6.35 mm |
| Shaft length | 21 mm |
| Supply voltage limits | 18…40 V |
| Current consumption | 3500 mA maximum continuous |
| Associated fuse rating | 10 A |
| Commissioning interface | RS485 (9.6, 19.2 and 38.4 kbauds) |
| Input/output type | 4 signals (each be used as input or output) |
| Voltage state 0 guaranteed | -3...4.5 V |
| Voltage state 1 guaranteed | 15...30 V |
| Discrete input current | 10 mA at 24 V on/STO_A for safety input; 3 mA at 24 V on/STO_B for safety input; 10 mA at 24 V for 24 V signal interface |
| Discrete output voltage | 10...30 V |
| Maximum switching current | 100 mA per output; 200 mA total |
| Protection type | Safe torque off; Overload of output voltage; Short circuit of the output voltage |
| Peak stall torque | 0.9 N.m |
| Continuous stall torque | 0.9 N.m |
| Speed feedback resolution | 20000 points/turn |
| Accuracy error | +/- 6 arc min |
| Rotor inertia | 0.22 kg.cm² |
| Maximum mechanical speed | 3000 rpm |
| Maximum radial force Fr | 24 N |
| Maximum axial force Fa | 100 N (tensile force); 8.4 N (force pressure) |
| Service life in hours | 20000 h bearing |
| Marking | CE |
| Type of cooling | Natural convection |
| Net weight | 1.6 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN 50347; EN/IEC 50178; EN 61800-3 : 2001-02; IEC 61800-3, Ed 2; IEC 60072-1; EN 61800-3:2001, second environment; EN/IEC 61800-3 |
| Product certifications | TÜV; UL; cUL |
| Ambient air temperature for operation | 50…65 °C (with power derating of 2 % per °C); 0…50 °C (without derating) |
| Permissible ambient air temperature around the device | 110 °C motor |
| Ambient air temperature for storage | -25…70 °C |
| Relative humidity | 15…85 % without condensation |
| Vibration resistance | 20 m/s² (f= 10…500 Hz) 10 cycles conforming to EN/IEC 60068-2-6 |
| Shock resistance | 150 m/s² 1000 shocks conforming to EN/IEC 60068-2-29 |
| IP degree of protection | IP41 shaft bushing: conforming to EN/IEC 60034-5; IP54 total except shaft bushing: conforming to EN/IEC 60034-5 |
| Main |
| Range of product | Lexium integrated drive |
| Product or component type | Motion integrated drive |
| Device short name | ILS |
| Motor type | 3-phase stepper motor |
| Number of motor poles | 6 |
| Network number of phases | Single phase |
| [Us] rated supply voltage | 24 V; 36 V |
| Network type | DC |
| Communication interface | I/O for motion sequence, integrated |
| Length | 115.9 mm |
| Winding type | Medium speed of rotation and medium torque |
| Electrical connection | Printed circuit board connector |
| Holding brake | Without |
| Gear box type | Without |
| Nominal speed | 300 rpm at 24 V; 600 rpm at 36 V |
| Nominal torque | 0.9 N.m |
| Holding torque | 1.02 N.m |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 10.5 cm |
| Package 1 Width | 19.0 cm |
| Package 1 Length | 39.0 cm |
| Package 1 Weight | 2.4 kg |
The integrated stepper motor of the Lexium ILS1 series by Schneider Electric, type ILS1M572PB1A0, is a decentralized motion drive consisting of a compact 3-phase stepper motor and integrated control electronics. It is designed for industrial applications requiring precise, reliable, and compact motion control. The motor features a rated voltage of 24 V and 36 V DC and is designed for single-phase supply. The winding is optimized for medium speeds and medium torque, making it suitable for drives with moderate speed requirements. The rated speed is 300 rpm at 24 V and 600 rpm at 36 V, with a rated torque of 0.9 Nm. The holding torque is 1.02 Nm, ensuring high stability at standstill. Speed feedback is provided with 20000 points per revolution, enabling high positioning accuracy with an accuracy error of +/- 6 arc minutes.
Applications
This drive is suitable for industrial automation systems, particularly in machine building, packaging technology, machine tools, and other applications requiring precise motion sequences. The integrated electronics reduce the need for external control devices and enable direct control via an I/O interface. The safety function Safe Torque Off (STO) ensures safe operation by switching off torque in case of a fault. The maximum mechanical speed is 3000 rpm, with bearings offering a service life of 20000 hours.
Functions and Equipment in Detail
The motor features a smooth shaft with a diameter of 6.35 mm and a length of 21 mm. Mounting is via a flange with a flange size of 57 mm, including four mounting holes with a diameter of 5.2 mm and a circle diameter of 66.6 mm. A centering ring with a diameter of 38.1 mm and a depth of 1.6 mm supports precise alignment. Electrical control is via board connectors, enabling easy integration into existing systems. Communication is via an integrated I/O interface used for motion sequences. The commissioning interface is RS485, with transmission speeds of 9.6, 19.2, and 38.4 kBaud. The I/O interface includes 4 signals, each configurable as input or output.
Technology Explained Simply
The integrated drive combines motor and control in a single housing, simplifying installation and maintenance. Feedback is provided via an index pulse indicating the exact rotor position. The maximum current draw is 3500 mA at continuous load, with a recommended fuse rating of 10 A. The protection rating is IP54 (overall, except shaft bearing) and IP41 (shaft bearing), providing protection against dust and splashing water, making it suitable for industrial environments. Cooling is by natural convection, eliminating the need for additional fans or cooling devices. The maximum ambient temperature for the device is 110 °C, with operation at 50…65 °C resulting in a performance drop of 2 % per °C. No performance drop occurs between 0…50 °C. Storage is possible at -25…70 °C.
Compatibility and Accessories
Various accessories are available for this drive to extend functionality. These include gearboxes from the PLE060 series with various gear ratios (e.g. I=4, I=5, I=8, I=12, I=15, I=16, I=20, I=40), right-angle gearboxes (e.g. I=40, I=8), cable entries (e.g. D5–9 mm IP54), cable sets for STO signals and I/O signals (e.g. 3 m length), and installation kits. These components allow adaptation to specific drive requirements and mechanical conditions.
Mounting and Installation
Mounting is via the designated flange with the 4 mounting holes. Fastening is done using screws, with hole diameters and circle diameter precisely defined. Electrical connection is via board connectors, ensuring a secure and reliable connection. Installation requires no additional cooling measures, as cooling is by natural convection. The operating altitude is up to 1000 m without performance reduction.
Advantages in Operation
The integrated drive offers high positioning accuracy, high holding torque at standstill, and a compact design. The integrated electronics reduce the number of required components and simplify system architecture. The STO safety function enhances operational safety. The long bearing life and robust construction ensure reliable long-term use. Natural cooling and compact design reduce space requirements and maintenance effort. Control via I/O interface enables flexible integration into existing control systems.
Certifications and Standards
The drive complies with standards EN 50347, EN/IEC 50178, EN 61800-3:2001-02, IEC 61800-3, edition 2, IEC 60072-1, and EN/IEC 61800-3. Product certifications include TÜV, UL, and cUL. The CE marking confirms conformity with European directives. Relative humidity is 15…85 %, with condensation not permitted. Vibration resistance is 20 m/s² (f=10…500 Hz) over 10 cycles, and shock resistance is 150 m/s² over 1000 shocks, according to EN/IEC 60068-2-6 and EN/IEC 60068-2-29.
Accessories and Extensions
Various accessories are available for this drive to extend functionality. These include gearboxes from the PLE060 series with various gear ratios (e.g. I=4, I=5, I=8, I=12, I=15, I=16, I=20, I=40), right-angle gearboxes (e.g. I=40, I=8), cable entries (e.g. D5–9 mm IP54), cable sets for STO signals and I/O signals (e.g. 3 m length), and installation kits. These components allow adaptation to specific drive requirements and mechanical conditions.
Operation and Maintenance
The drive is designed for operation up to 1000 m altitude without performance reduction. The ambient temperature during operation is 0…50 °C without performance drop, and 50…65 °C with a performance drop of 2 % per °C. Storage is possible at -25…70 °C. Relative humidity is 15…85 %, with condensation not permitted. Vibration resistance is 20 m/s² (f=10…500 Hz) over 10 cycles, and shock resistance is 150 m/s² over 1000 shocks, according to EN/IEC 60068-2-6 and EN/IEC 60068-2-29. Cooling is by natural convection, requiring no additional cooling measures. The bearing service life is 20000 hours.
Safety and Conformity
The drive features the Safe Torque Off (STO) safety function, which safely switches off torque in case of a fault. The protection rating IP54 (overall, except shaft bearing) and IP41 (shaft bearing) provides protection against dust and splashing water. Certifications include TÜV, UL, and cUL. The CE marking confirms conformity with European directives. Standards EN 50347, EN/IEC 50178, EN 61800-3:2001-02, IEC 61800-3, edition 2, IEC 60072-1, and EN/IEC 61800-3 are met. The maximum ambient temperature for the device is 110 °C.