| Complementary |
| Range compatibility | TeSys GV2ME; TeSys GV2LE; TeSys GV2L; TeSys GV2P; TeSys GV3L; TeSys GV3P; TeSys Deca |
| Control circuit voltage limits | 0.85...1.1 Un |
| [Ui] rated insulation voltage | 690 V AC conforming to IEC 60947-1; 600 V AC conforming to UL 60947-4-1; 600 V AC conforming to CSA C22.2 No 60947-4-1 |
| Threshold tripping voltage | 0.7...0.35 Un |
| Inrush power in VA | 12 VA AC |
| Inrush power in W | 8 W |
| Hold-in power consumption in VA | 3.5 VA AC |
| Hold-in power consumption in W | 1.1 W |
| Operating time | 10...15 ms conforming to IEC 60947-1 |
| On-load factor | 100 % |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1…2.5 mm²solid; Screw clamp terminals 2 cable(s) 1…2.5 mm²solid; Screw clamp terminals 1 cable(s) 0.75…2.5 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 0.75…2.5 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 0.75…1.5 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 0.75…1.5 mm²flexible with cable end |
| Tightening torque | < 1.4 N.m on screw clamp terminals |
| Mechanical durability | 10000 cycles with GV3P and GV3L; 30000 cycles with GV2ME and GV2P |
| Quantity per set | Set of 10 |
| Height | 89 mm |
| Width | 18 mm |
| Depth | 66 mm |
| Net weight | 0.105 kg |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Logistical informations |
| Country of origin | CZ |
| Main |
| Range | TeSys; TeSys Deca |
| Product or component type | Undervoltage release |
| Device short name | GVAU |
| [Uc] control circuit voltage | 380...400 V AC 50 Hz; 440 V AC 60 Hz |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.700 cm |
| Package 1 Width | 8.500 cm |
| Package 1 Length | 9.300 cm |
| Package 1 Weight | 107.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 42 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.830 kg |
The
undervoltage release GVAU385 from
Schneider Electric belongs to the
TeSys and
TeSys Deca series and serves as an accessory for motor protection circuit breakers of types GV2 and GV3. It is used to automatically disconnect the motor protection circuit breaker in the event of a power interruption or voltage drop, thereby protecting the connected motor from damage due to uncontrolled operation. Installation is carried out on the right side of the motor protection circuit breaker, with compatibility provided for models GV2ME, GV2LE, GV2L, GV2P, GV3L, GV3P, as well as the TeSys Deca series.
Applications
The undervoltage release is designed for industrial applications where reliable disconnection during voltage dips is required. It is frequently used in installations with motors that must not be operated without external control or with the risk of uncontrolled restart. The application is in control circuits with a rated voltage of 380 to 400 V AC at 50 Hz and 440 V AC at 60 Hz. The rated insulation voltage is 690 V AC according to IEC 60947-1, enabling use in industrial environments with high electrical loads.
Functions and Features in Detail
The release responds to voltage fluctuations in the control circuit and triggers when the voltage drops below 70 % of the nominal voltage (0.7 Un). The release function operates at voltage levels between 0.35 and 0.7 Un, with the exact threshold setting predefined in the device. The operating time is 10 to 15 ms, corresponding to a rapid response to voltage dips. The pickup power is 12 VA (8 W) and the holding power consumption is 3.5 VA (1.1 W), ensuring efficient power supply in the control circuit. The mechanical life is 10,000 cycles when used with GV3P and GV3L, and 30,000 cycles with GV2ME and GV2P.
Technology Explained Simply
The undervoltage release operates as an electromagnetic auxiliary contact connected via a control circuit. At normal voltage, the release remains activated and holds the motor protection circuit breaker in the on position. When the voltage drops below the predefined threshold, the electromagnetic drive is deactivated, causing the switch to automatically disconnect. The screw terminals allow connection with cables in cross-sections from 0.75 to 2.5 mm², supporting both flexible cables with or without cable ends and rigid cables. The maximum tightening torque is less than 1.4 Nm, ensuring secure and tool-appropriate installation.
Compatibility and Accessories
The GVAU385 is specifically designed for motor protection circuit breakers in the TeSys GV2 and GV3 series, particularly for models GV2ME and GV3P. It can be combined with various motor protection circuit breakers, including GV2L04, GV2P06, GV2P21, GV2P20, GV2RT10, GV3P25, GV2P05, GV2L20, GV3L32, GV2LE32, GV3P73, GV2ME08, GV2RT08, GV2P07, GV2LE22, GV2LE05, GV2ME21, GV2L10, GV2ME07, and GV2ME02. The combination is achieved by mounting on the right side of the motor protection circuit breaker, with electrical connection made via the screw terminals.
Installation and Mounting
Mounting is performed on the right side of the motor protection circuit breaker, using the terminals for connection to the control circuit. Cable cross-sections from 0.75 to 2.5 mm² can be connected as either rigid or flexible conductors, with or without cable ends. The maximum tightening torque is less than 1.4 Nm, ensuring a secure connection without overloading the terminals. The device dimensions are 89 mm (height), 18 mm (width), and 66 mm (depth), allowing integration into standard enclosures. The product weight is 0.105 kg.
Operational Advantages
The use of the undervoltage release ensures safe disconnection during voltage dips, which is particularly important in installations with motors to avoid unintended restarts or damage. The fast operating time of 10 to 15 ms enables reactive disconnection, while the high mechanical life promises long-term use without maintenance. Compatibility with various motor protection circuit breakers in the TeSys family offers flexibility in system design. The dark grey color and compact design integrate seamlessly into existing control panels without requiring additional space. The warranty period is 18 months.