| Complementary |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1; AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity | 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Toggle |
| [In] rated current | 4 A |
| Thermal protection adjustment range | 2.5…4 A conforming to IEC 60947-2 |
| Magnetic tripping current | 78 A |
| [Ith] conventional free air thermal current | 4 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 2.5 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In; 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections - terminals | Power circuit: screw clamp terminal 2 cable(s) 1…6 mm² - solid; Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² - flexible without cable end; Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² - flexible with cable end |
| Tightening torque | 1.7 N.m - on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped; Panel: screwed (with adaptor plate) |
| Mounting position | Horizontal; Vertical |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 78.5 mm |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-2; EN/IEC 60947-4-1 |
| Product certifications | CB Scheme; CE; UKCA; CCC; cULus; EAC; LROS (Lloyds register of shipping); BV |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms; Vibrations: 5 Gn, 5...150 Hz |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys Deca |
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2RT |
| Device application | Motor protection; Transformer |
| Trip unit technology | Thermal-magnetic |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.500 cm |
| Package 1 Width | 9.400 cm |
| Package 1 Length | 4.800 cm |
| Package 1 Weight | 250.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.330 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 111.780 kg |
The GV2RT08 motor protection switch from the TeSys Deca series by Schneider Electric is a 3-pole power switch designed for use in industrial and technical installations. It provides protection for electric motors and transformers and features a thermal-magnetic tripping mechanism that responds to both overloads and short circuits. The device is designed for operation in AC networks with a frequency of 50/60 Hz and offers a rated operational voltage of 690 V AC. The rated current is 4 A, with the thermal protection adjustable within a range of 2.5 to 4 A. The magnetic tripping current is set at 78 A, enabling rapid response to sudden current surges. The toggle switch design ensures simple and intuitive operation.
Applications
The GV2RT08 is designed for use in installations with start motors and stop motors. It is particularly suitable for applications requiring reliable protection against thermal overload and electrical short circuits. Category A according to IEC 60947-2, along with usage categories AC-3 and AC-3e according to IEC 60947-4-1, define its use in motor control applications. The devices are also suitable for use in transformer installations, where the thermal tripping monitors operation under load conditions.
Functions and Equipment in Detail
The protection switch features a thermal tripping function based on heat generation from current flow, and a magnetic tripping function that activates during sudden current increases. The thermal tripping is adjustable within a range of 2.5 to 4 A, allowing adaptation to different motor power ratings. The magnetic tripping responds at a current of 78 A, ensuring rapid disconnection under short-circuit conditions. The mechanical life expectancy is 100,000 cycles, and the electrical life expectancy is also 100,000 cycles under AC-3 operation at 415 V and rated current. The power loss per pole is 2.5 W, indicating low heat generation during operation.
Technology Explained Simply
The thermal-magnetic tripping technology combines two protection principles: the thermal component responds to slow, sustained overloads by activating the tripping mechanism through thermal expansion. The magnetic component, in contrast, responds to sudden, high current surges, such as those occurring during short circuits, and disconnects within milliseconds. The rated insulation voltage is 690 V AC, and the rated impulse voltage withstand is 6 kV, ensuring high electrical safety. The operating ambient temperature ranges from -20 °C to 60 °C, making the device suitable for use in industrial environments with varying temperatures.
Compatibility and Accessories
The GV2RT08 can be combined with various accessories to extend its functionality. These include auxiliary switches such as the GVAD1010 (1Sf+1S) or GVAD0110 (1Öf+1S), which can be used for additional control and signaling tasks. Undervoltage release units such as the GVAU505 (500 VAC) or GVAU225 (220–240 V) enable disconnection during voltage dips. Adapter plates like the GV2AF02 allow mounting on consoles, and connection blocks like the GV2AF3 can be used for integration with contactors such as LC1-D09–D38. These components expand the application possibilities of the protection switch in complex control systems.
Mounting and Installation
The protection switch is clipped onto a 35 mm symmetrical DIN rail, with panel mounting also possible using an adapter plate. Mounting can be performed either horizontally or vertically. Connections are made via screw terminals designed for rigid cables with 1 to 6 mm² and flexible cables with 1.5 to 6 mm² (without cable end) or 1 to 4 mm² (with cable end). The required tightening torque is 1.7 Nm. The protection class IP20 according to IEC 60529 protects against finger contact and ingress of solid foreign objects larger than 12.5 mm, but does not protect against water or dust. The protection class IK04 protects against mechanical impacts with an energy of up to 0.5 J.
Advantages in Operation
The GV2RT08 offers high reliability through its thermal-magnetic tripping, which responds to both prolonged overloads and sudden short circuits. Its compact design with a width of 45 mm allows dense mounting in enclosures. The simple operation via the toggle switch and the clear indication of the switching state facilitate maintenance and commissioning. The high life expectancy of 100,000 cycles, both mechanically and electrically (under AC-3), ensures long-term use. Certifications according to EN/IEC 60947-2 and EN/IEC 60947-4-1, along with product certifications such as CE, UKCA, cULus, and CCC, guarantee compliance with international safety and quality standards.