| Complementary |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1; AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity | 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Toggle |
| [In] rated current | 2.5 A |
| Thermal protection adjustment range | 1.6…2.5 A conforming to IEC 60947-2 |
| Magnetic tripping current | 51 A |
| [Ith] conventional free air thermal current | 2.5 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 2.5 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In; 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections - terminals | Power circuit: screw clamp terminal 2 cable(s) 1…6 mm² - solid; Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² - flexible without cable end; Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² - flexible with cable end |
| Tightening torque | 1.7 N.m - on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped; Panel: screwed (with adaptor plate) |
| Mounting position | Horizontal; Vertical |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 78.5 mm |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-2; EN/IEC 60947-4-1 |
| Product certifications | CB Scheme; CE; UKCA; CCC; cULus; EAC; LROS (Lloyds register of shipping); BV |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms; Vibrations: 5 Gn, 5...150 Hz |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys Deca |
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2RT |
| Device application | Motor protection; Transformer |
| Trip unit technology | Thermal-magnetic |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.500 cm |
| Package 1 Width | 9.500 cm |
| Package 1 Length | 4.800 cm |
| Package 1 Weight | 257.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.472 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 111.552 kg |
The GV2RT07 from Schneider Electric is a motor protection switch from the TeSys Deca series, specifically designed for use in industrial applications. It provides protection for electric motors and transformers and features a thermomagnetic tripping technology that responds to both overloads and short circuits. The device is designed as a 3-pole switch for AC networks in the frequency range of 50/60 Hz. The rated operational voltage is 690 V AC, with the rated insulation voltage also being 690 V AC. The rated impulse voltage withstand is 6 kV, highlighting its suitability for applications with high electrical stress.
Motor protection switch with thermal and magnetic tripping enables precise and reliable protection. The thermal tripping mechanism responds to continuous overloads within the setting range of 1.6 to 2.5 A, with the rated current (In) being 2.5 A. The magnetic tripping current is set at 51 A to respond quickly to sudden current surges, such as those occurring during short circuits. The conventional thermal current (Ith) is also 2.5 A, indicating the thermal load capacity of the device. The power loss per pole is 2.5 W, indicating efficient heat dissipation.
Applications include protection for motors in drive systems and for transformers in electrical distribution systems. The usage category corresponds to Category A according to IEC 60947-2, as well as AC-3 and AC-3e according to IEC 60947-4-1, confirming suitability for motor start-stop functions. The device is designed for an operating environment of -20 to 60 °C, with a storage temperature range of -40 to 80 °C. Mechanical robustness is ensured by shock resistance of 30 Gn for 11 ms and vibration resistance of 5 g in the frequency range of 5–150 Hz.
Technology explained simply shows that the switch features a toggle switch for control, enabling easy operation. Connections are made via screw terminals designed for rigid cables with a cross-section of 1 to 6 mm², and for flexible cables with 1.5 to 6 mm² (without cable end) and 1 to 4 mm² (with cable end). The tightening torque is 1.7 Nm. Mounting is either on a 35 mm symmetrical DIN rail (clamped) or on a plate (screwed, with adapter plate). Mounting orientation can be horizontal or vertical. Dimensions are 45 mm (width), 89 mm (height), and 78.5 mm (depth).
Compatibility and accessories include various expansion options for adapting to specific requirements. These include undervoltage release units such as the GVAU225 (220–240 V 50 Hz) or GVAU505 (500 VAC 50/60 Hz), current release units such as the GVAS226 (220–240 VAC 60 Hz) or GVAS207 (200 VAC 50/60 Hz), and auxiliary switches such as the GVAN20 (2S side, screw connection) or GVAE1 (1S or 1NC, front, screw connection). Additionally, adapter plates such as the GV2AF02 for console mounting are available, as well as connection blocks such as the GV2AF3 for connecting to contactors of the LC1-D09-D38 series.
Mounting and installation are performed by securing to a DIN rail or a plate using an adapter plate. The screw terminals allow for secure connections with cables within the specified cross-section range. The mechanical life is 100,000 cycles, and the electrical life is also 100,000 cycles under AC-3 operation at 415 V and rated current. The rated power is continuous according to IEC 60947-4-1. The protection rating is IP20 according to IEC 60529, providing protection against finger contact and against solid foreign objects larger than 12.5 mm. The IK04 protection rating provides protection against mechanical impacts. Flame resistance is 960 °C according to IEC 60695-2-11.
Operational advantages lie in the combination of compact design, high reliability, and easy handling. The thermomagnetic tripping ensures precise protection against overload and short circuit. The high breaking capacity of 100 kA Icu at voltages up to 500 V AC and 3 kA Icu at 690 V AC provides safety in demanding industrial environments. Certifications according to EN/IEC 60947-2 and EN/IEC 60947-4-1, as well as product certifications CB, CE, UKCA, CCC, cULus, EAC, and LROS (Lloyds Register of Shipping), confirm compliance with international standards. Climate resistance corresponds to IACS E10, emphasizing suitability for marine and industrial applications.