Schneider Electric GV2RT07, EAN: 3389110520637

Schneider Electric GV2RT07 motor protection switch 3p toggle lever

Industrial Material > Control devices / Pilot devices > Motor protection switch

Schneider Electric GV2RT07 motor protection switch 3p toggle lever

Lieske Part No. 989065
Mfg Part No GV2RT07
EAN-Code 3389110520637
Manufacturer Schneider Electric
Here only 93,29 EUR
111,02 EUR incl. VAT

Further information for Schneider Electric GV2RT07 motor protection switch 3p toggle lever

Complementary
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1; AC-3e conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-2
Breaking capacity100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeToggle
[In] rated current2.5 A
Thermal protection adjustment range1.6…2.5 A conforming to IEC 60947-2
Magnetic tripping current51 A
[Ith] conventional free air thermal current2.5 A conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole2.5 W
Mechanical durability100000 cycles
Electrical durability100000 cycles for AC-3 at 415 V In; 100000 cycles for AC-3e at 415 V In
Rated dutyUninterrupted conforming to IEC 60947-4-1
Connections - terminalsPower circuit: screw clamp terminal 2 cable(s) 1…6 mm² - solid; Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² - flexible without cable end; Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² - flexible with cable end
Tightening torque1.7 N.m - on screw clamp terminal
Fixing mode35 mm symmetrical DIN rail: clipped; Panel: screwed (with adaptor plate)
Mounting positionHorizontal; Vertical
Width45 mm
Height89 mm
Depth78.5 mm
Contractual warranty
Warranty (in months)18
Environment
StandardsEN/IEC 60947-2; EN/IEC 60947-4-1
Product certificationsCB Scheme; CE; UKCA; CCC; cULus; EAC; LROS (Lloyds register of shipping); BV
IK degree of protectionIK04
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandconforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 30 Gn for 11 ms; Vibrations: 5 Gn, 5...150 Hz
Logistical informations
Country of originFR
Main
RangeTeSys Deca
Product nameTeSys GV2
Product or component typeMotor circuit breaker
Device short nameGV2RT
Device applicationMotor protection; Transformer
Trip unit technologyThermal-magnetic
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.500 cm
Package 1 Width9.500 cm
Package 1 Length4.800 cm
Package 1 Weight257.000 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.472 kg
Unit Type of Package 3P06
Number of Units in Package 3384
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight111.552 kg
The GV2RT07 from Schneider Electric is a motor protection switch from the TeSys Deca series, specifically designed for use in industrial applications. It provides protection for electric motors and transformers and features a thermomagnetic tripping technology that responds to both overloads and short circuits. The device is designed as a 3-pole switch for AC networks in the frequency range of 50/60 Hz. The rated operational voltage is 690 V AC, with the rated insulation voltage also being 690 V AC. The rated impulse voltage withstand is 6 kV, highlighting its suitability for applications with high electrical stress.

Motor protection switch with thermal and magnetic tripping enables precise and reliable protection. The thermal tripping mechanism responds to continuous overloads within the setting range of 1.6 to 2.5 A, with the rated current (In) being 2.5 A. The magnetic tripping current is set at 51 A to respond quickly to sudden current surges, such as those occurring during short circuits. The conventional thermal current (Ith) is also 2.5 A, indicating the thermal load capacity of the device. The power loss per pole is 2.5 W, indicating efficient heat dissipation.

Applications include protection for motors in drive systems and for transformers in electrical distribution systems. The usage category corresponds to Category A according to IEC 60947-2, as well as AC-3 and AC-3e according to IEC 60947-4-1, confirming suitability for motor start-stop functions. The device is designed for an operating environment of -20 to 60 °C, with a storage temperature range of -40 to 80 °C. Mechanical robustness is ensured by shock resistance of 30 Gn for 11 ms and vibration resistance of 5 g in the frequency range of 5–150 Hz.

Technology explained simply shows that the switch features a toggle switch for control, enabling easy operation. Connections are made via screw terminals designed for rigid cables with a cross-section of 1 to 6 mm², and for flexible cables with 1.5 to 6 mm² (without cable end) and 1 to 4 mm² (with cable end). The tightening torque is 1.7 Nm. Mounting is either on a 35 mm symmetrical DIN rail (clamped) or on a plate (screwed, with adapter plate). Mounting orientation can be horizontal or vertical. Dimensions are 45 mm (width), 89 mm (height), and 78.5 mm (depth).

Compatibility and accessories include various expansion options for adapting to specific requirements. These include undervoltage release units such as the GVAU225 (220–240 V 50 Hz) or GVAU505 (500 VAC 50/60 Hz), current release units such as the GVAS226 (220–240 VAC 60 Hz) or GVAS207 (200 VAC 50/60 Hz), and auxiliary switches such as the GVAN20 (2S side, screw connection) or GVAE1 (1S or 1NC, front, screw connection). Additionally, adapter plates such as the GV2AF02 for console mounting are available, as well as connection blocks such as the GV2AF3 for connecting to contactors of the LC1-D09-D38 series.

Mounting and installation are performed by securing to a DIN rail or a plate using an adapter plate. The screw terminals allow for secure connections with cables within the specified cross-section range. The mechanical life is 100,000 cycles, and the electrical life is also 100,000 cycles under AC-3 operation at 415 V and rated current. The rated power is continuous according to IEC 60947-4-1. The protection rating is IP20 according to IEC 60529, providing protection against finger contact and against solid foreign objects larger than 12.5 mm. The IK04 protection rating provides protection against mechanical impacts. Flame resistance is 960 °C according to IEC 60695-2-11.

Operational advantages lie in the combination of compact design, high reliability, and easy handling. The thermomagnetic tripping ensures precise protection against overload and short circuit. The high breaking capacity of 100 kA Icu at voltages up to 500 V AC and 3 kA Icu at 690 V AC provides safety in demanding industrial environments. Certifications according to EN/IEC 60947-2 and EN/IEC 60947-4-1, as well as product certifications CB, CE, UKCA, CCC, cULus, EAC, and LROS (Lloyds Register of Shipping), confirm compliance with international standards. Climate resistance corresponds to IACS E10, emphasizing suitability for marine and industrial applications.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/989065