Schneider Electric GV2ME02, EAN: 3389110342970

Schneider Electric GV2ME02 - TeSys GV2-Circuit breaker-thermal-magnetic-0.16...0.25 A-screw clamp te

Industrial Material > Control devices / Pilot devices > Motor protection switch

Schneider Electric GV2ME02 - TeSys GV2-Circuit breaker-thermal-magnetic-0.16...0.25 A-screw clamp te

Lieske Part No. 267586
Mfg Part No GV2ME02
EAN-Code 3389110342970
Manufacturer Schneider Electric
Here only 82,93 EUR
98,69 EUR incl. VAT

Further information for Schneider Electric GV2ME02 - TeSys GV2-Circuit breaker-thermal-magnetic-0.16...0.25 A-screw clamp te

Complementary
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1; AC-3e conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-2
Motor power kW0.06 kW at 400/415 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typePush-button
[In] rated current0.25 A
Thermal protection adjustment range0.16…0.25 A conforming to IEC 60947-2
Magnetic tripping current3.08 A
[Ith] conventional free air thermal current0.25 A conforming to IEC 60947-2
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole2.5 W
Mechanical durability100000 cycles
Electrical durability100000 cycles for AC-3 at 415 V In; 100000 cycles for AC-3e at 415 V In
Rated dutyUninterrupted conforming to IEC 60947-4-1
Connections - terminalsPower circuit: screw clamp terminal 2 cable(s) 1…6 mm² - solid; Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² - flexible without cable end; Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² - flexible with cable end
Tightening torque1.7 N.m - on screw clamp terminal
Fixing mode35 mm symmetrical DIN rail: clipped; Panel: screwed (with adaptor plate)
Mounting positionHorizontal; Vertical
Width45 mm
Height89 mm
Depth78.5 mm
Net weight0.26 kg
ColourDark grey
Contractual warranty
Warranty (in months)18
Environment
StandardsEN/IEC 60947-2; EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; IEC/EN 60335-2-40:Annex JJ; IEC/EN 60335-1:Clause 30.2
Product certificationsCB Scheme; CE; UKCA; CCC; cULus; EAC; ATEX; LROS (Lloyds register of shipping); BV; RINA; DNV-GL
IK degree of protectionIK04
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandconforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 30 Gn for 11 ms; Vibrations: 5 Gn, 5...150 Hz
Logistical informations
Country of originFR
Main
RangeTeSys Deca
Product nameTeSys GV2
Product or component typeMotor circuit breaker
Device short nameGV2ME
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.700 cm
Package 1 Width8.500 cm
Package 1 Length9.300 cm
Package 1 Weight230.000 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight5.710 kg
Unit Type of Package 3P06
Number of Units in Package 3384
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight99.360 kg
Motor circuit breaker GV2 / GV3
A simple solution to control the motor during startup and
protect:
- For motor feeders up to 40 kW/400V
- To switch from continuous currents up to 80 A
- Self Short circuit protection up to 25 A (3 GV-ME ..)

System Description
By additional components, the following important features can be produced:
- Main switch by closing device in the OFF position
- Emergency stop device by screw-head pushbutton (housing)
- Protection against independent restart after power failures by undervoltage release
Motor circuit breaker GV2-ME
- With thermal and magnetic trip
- Operation via buttons
- Rated voltage 400 V, AC-3
- Connection: screw
Setting range: 0.16 ... 0.25 A Type: GV2-ME02


Quantity: 1 unit.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/267586
qrcode für Schneider Electric GV2ME02 - TeSys GV2-Circuit breaker-thermal-magnetic-0.16...0.25 A-screw clamp te