| Complementary |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1; AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 0.25 kW at 400/415 V AC 50/60 Hz; 0.37 kW at 400/415 V AC 50/60 Hz; 0.37 kW at 500 V AC 50/60 Hz; 0.55 kW at 690 V AC 50/60 Hz; 0.75 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Toggle |
| [In] rated current | 1 A |
| Magnetic tripping current | 15.1 A |
| [Ith] conventional free air thermal current | 1 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 1.8 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In; 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections - terminals | Power circuit: screw clamp terminal 2 cable(s) 1…6 mm² - solid; Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² - flexible without cable end; Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² - flexible with cable end |
| Tightening torque | 1.7 N.m - on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped; Panel: screwed (with adaptor plate) |
| Mounting position | Horizontal; Vertical |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 78.5 mm |
| Net weight | 0.33 kg |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-2; EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; IEC/EN 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CE; UKCA; CCC; cULus; EAC; LROS (Lloyds register of shipping); BV; RINA; DNV-GL |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms; Vibrations: 5 Gn, 5...150 Hz |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys Deca |
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2LE |
| Device application | Motor protection |
| Trip unit technology | Magnetic |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.5 cm |
| Package 1 Width | 9.2 cm |
| Package 1 Length | 5.0 cm |
| Package 1 Weight | 224.0 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 24 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 5.708 kg |
The GV2LE05 motor protection switch from the TeSys Deca series by Schneider Electric is a
motor power switch designed for use in industrial applications. It provides
motor protection functionality, safeguarding electric motors against overload and short-circuit. The device features
magnetic tripping technology and is designed for operation in
AC networks with a frequency of 50/60 Hz. Control is achieved via a
toggle switch, enabling simple and intuitive operation.
Applications
This switch is designed for applications involving
starter motors and
stop motors. It is suitable for small to medium-sized motors in industrial machinery, conveyor systems, pumps, or fan installations. The usage category includes
Category A according to IEC 60947-2, as well as
AC-3 and
AC-3e according to IEC 60947-4-1, confirming its suitability for operation with three-phase motors under normal and increased load conditions.
Functions and Features in Detail
The GV2LE05 offers
thermal and magnetic tripping, enabling it to respond to both prolonged overloads and sudden short-circuits. The
rated current (In) is 1 A, and the
magnetic tripping current is 15.1 A. The thermal tripping protects against overload, while the magnetic tripping rapidly disconnects in case of sudden current surges, such as those occurring during short-circuits. The
rated operational voltage (Ue) is 690 V AC, allowing use in high-voltage installations. The
rated insulation voltage (Ui) is also 690 V AC, and the
rated impulse voltage withstand (Uimp) is 6 kV, ensuring high electrical strength.
Technical Details Explained
The
breaking capacity is 100 kA Icu at various voltage levels (230/240 V to 690 V AC), ensuring safe interruption even under high short-circuit currents. The
rated operational short-circuit breaking capacity (Ics) is 100 % of the Icu values, ensuring reliability under underloaded conditions. The
mechanical life is 100,000 cycles, and the
electrical life is also 100,000 cycles under AC-3 operation at 415 V. The
power loss per pole is 1.8 W, indicating efficient heat generation. The
conventional thermal current (Ith) is 1 A in free air, describing the thermal load capacity.
Compatibility and Accessories
The switch is designed for mounting on a
35 mm symmetrical DIN rail and can also be mounted on a panel, requiring an
adapter plate. Compatible accessories include auxiliary switches such as the
GVAM11 (1W, fault) or
GVAD1010 (1Sf+1S, side), as well as undervoltage release units such as the
GVAU386 (380–400 VAC) or
GVAU505 (500 VAC). Load current release units such as the
GVAS207 (200 VAC) or
GVAS385 (380–400 V) can be used additionally. For integration into busbar systems, models such as the
GV2G472 (63 A, 4 outlets) are available.
Mounting and Installation
Mounting is either on a DIN rail (clamped) or on a panel (screwed, with adapter plate). The
mounting position can be horizontal or vertical. Dimensions are
45 mm width, 89 mm height, and 78.5 mm depth. The
product weight is 0.33 kg. The
tightening torque for the screw terminals is 1.7 Nm. The terminals are designed for
rigid cables (1–6 mm²),
flexible cables without cable ends (1.5–6 mm²), and
flexible cables with cable ends (1–4 mm²).
Operational Advantages
The switch features high
mechanical robustness, with shock resistance of 30 Gn for 11 ms and vibration resistance of 5 g in the frequency range 5–150 Hz. The
operating ambient temperature ranges from -20 °C to 60 °C, while the
storage temperature ranges from -40 °C to 80 °C. The
flame resistance is 960 °C according to IEC 60695-2-11. The
protection rating IP20 according to IEC 60529 protects against finger contact and solid foreign objects, while
protection rating IK04 provides protection against mechanical impacts. The
climate resistance corresponds to IACS E10, confirming suitability for industrial environments. The
certifications include CE, UKCA, CCC, cULus, EAC, LROS, BV, RINA, and DNV-GL, as well as standards EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
The device is finished in
dark grey and features a compact design, saving space in standard enclosures. The
rated power is uninterrupted according to IEC 60947-4-1, ensuring continuous operational capability. The
suitability for isolation is confirmed according to IEC 60947-1, enabling use in isolated circuits.