| Complementary |
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2; AC-3 conforming to IEC 60947-4-1; AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 3 kW at 400/415 V AC 50/60 Hz; 4 kW at 400/415 V AC 50/60 Hz; 4 kW at 500 V AC 50/60 Hz; 5.5 kW at 690 V AC 50/60 Hz; 7.5 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2; 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2; 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2; 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2; 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type | Rotary handle |
| [In] rated current | 10 A |
| Magnetic tripping current | 149 A |
| [Ith] conventional free air thermal current | 14 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 1.8 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In; 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections - terminals | Power circuit: screw clamp terminal 2 cable(s) 1…6 mm² - solid; Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² - flexible without cable end; Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² - flexible with cable end |
| Tightening torque | 1.7 N.m - on screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail: clipped; Panel: screwed (with 2 x M4 screws) |
| Mounting position | Horizontal; Vertical |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 97 mm |
| Net weight | 0.33 kg |
| Colour | Dark grey |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-2; EN/IEC 60947-4-1; UL 60947-4-1; CSA C22.2 No 60947-4-1; IEC/EN 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; CE; UKCA; CCC; cULus; EAC; LROS (Lloyds register of shipping); BV; RINA; DNV-GL |
| IK degree of protection | IK04 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for storage | -40…80 °C |
| Fire resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient air temperature for operation | -20…60 °C |
| Mechanical robustness | Shocks: 30 Gn for 11 ms; Vibrations: 5 Gn, 5...150 Hz |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys Deca |
| Product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2L |
| Device application | Motor protection |
| Trip unit technology | Magnetic |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.700 cm |
| Package 1 Width | 9.200 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 321.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.601 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 320 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 113.000 kg |
The GV2L14 motor protection switch from the TeSys Deca series by Schneider Electric is a
motor power switch designed for use in industrial applications. It provides
motor protection functions, safeguarding electric motors against overload and short-circuit. The device features
magnetic tripping technology and is designed for operation in
AC networks with a frequency of 50/60 Hz. Control is performed via a
rotary handle, enabling simple operation and adjustment. The switch is suitable for use in
Category A according to IEC 60947-2, as well as for application categories
AC-3 and
AC-3e per IEC 60947-4-1, qualifying it for motor start and stop functions.
Applications
The GV2L14 is designed for use in industrial and commercial installations where reliable protection for electric motors is required. It is particularly suitable for applications where motors with a power up to 7.5 kW at 690 V AC are operated. The specified motor powers include 3 kW at 400/415 V, 4 kW at 400/415 V and 500 V, as well as 5.5 kW and 7.5 kW at 690 V AC. The protection function is achieved through
thermal and magnetic tripping, with the magnetic tripping current set at 149 A. The thermal tripping protects against sustained overload, while the magnetic tripping responds to sudden short-circuits.
Functions and Equipment in Detail
The switch has a
3-pole configuration (3P) and is rated for a
rated voltage (Ue) of 690 V AC. The
rated insulation voltage (Ui) is also 690 V AC, and the
rated impulse withstand voltage (Uimp) is 6 kV. The
rated current (In) is 10 A, with a
conventional thermal current (Ith) of 14 A in free air. The
power loss per pole is specified as 1.8 W. The
mechanical life is 100,000 cycles, as is the
electrical life under AC-3 and AC-3e operation at 415 V. The
rated power is uninterrupted according to IEC 60947-4-1.
Technology Explained Simply
The protection function of the GV2L14 is based on two principles: the thermal tripping responds to continuous overload by using a bimetallic strip that expands due to heat and triggers the switch to open. The magnetic tripping activates during sudden high currents, such as those occurring during short-circuits, and disconnects within milliseconds. The
breaking capacities vary depending on voltage level: 100 kA Icu at 230/240 V and 400/415 V, 20 kA at 440 V, 10 kA at 500 V, and 4 kA at 690 V. The
rated service short-circuit breaking capacity (Ics) is 100 % at 230/240 V, 400/415 V, and 500 V, as well as 75 % at 440 V and 100 % at 690 V.
Compatibility and Accessories
The switch can be combined with various accessories that extend its functionality. These include, for example,
load current release units such as the GVAS116 (110–115 VAC 60 Hz) or GVAS026 (24 VAC 60 Hz), and
under-voltage release units such as the GVAU207 (200 V 50/60 Hz) or GVAU385 (380–400 V 50 Hz). For integration into control panels,
connection blocks like the GV1G09 and
auxiliary switches such as the GVAD1001 (1NO+1NC side-mounted) or GVAE20 (2NO front-mounted) are available. Additionally,
busbar systems such as GV2G254, GV2G354, or GV2G445 are available for mounting in enclosures. Combining it with
power contactors like LC1D12B7 or LC1D12P7 enables integrated control.
Mounting and Installation
The GV2L14 can be clipped onto a
35 mm symmetrical DIN rail or mounted on a panel using two M4 screws. Mounting orientation is possible both
horizontally and
vertically. Dimensions are 45 mm width, 89 mm height, and 97 mm depth. The product weight is 0.33 kg. The
protection rating (IP) is IP20 according to IEC 60529, providing protection against finger contact and solid foreign objects, but not against water or dust. The
protection rating (IK) is IK04, indicating protection against mechanical impacts such as light shocks and blows. The
operating ambient temperature ranges from -20 °C to 60 °C, with storage temperature from -40 °C to 80 °C. The
flame resistance is 960 °C according to IEC 60695-2-11.
Operational Advantages
The GV2L14 offers high reliability and longevity, with both mechanical and electrical life rated at 100,000 cycles. Its compact design and DIN rail mounting simplify installation in enclosures. The clear operation via the rotary handle and the integrated protection against overload and short-circuit ensure safe and low-maintenance use. Certifications according to EN/IEC 60947-2, EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and IEC/EN 60335-2-40:Annex JJ guarantee compliance with international standards. The
climate resistance corresponds to IACS E10, highlighting its suitability for industrial environments.