Schneider Electric GV2G554, EAN: 3389110555851

Schneider Electric GV2G554 motor protection switch 63 A

Industrial Material > Control devices / Pilot devices > Motor protection switch

Schneider Electric GV2G554 motor protection switch 63 A

Lieske Part No. 560989
Mfg Part No GV2G554
EAN-Code 3389110555851
Manufacturer Schneider Electric
Here only 25,41 EUR
30,24 EUR incl. VAT

Further information for Schneider Electric GV2G554 motor protection switch 63 A

Complementary
Product certificationsCE; cULus
[Ui] rated insulation voltage690 V
Connection pitch54 mm
Width260 mm
Net weight0.1 kg
Contractual warranty
Warranty (in months)18
Logistical informations
Country of originRO
Main
RangeLinergy
Product nameFT
Device short nameGV2G
Product or component typeComb busbar
Accessory / separate part categoryConnection accessory
Poles description3P
Range compatibilityTeSys Deca; TeSys GV2; TeSys K; TeSys U
Fixing modeTerminals:
Number of tap-offs5
[Ith] conventional free air thermal current63 A
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height1.000 cm
Package 1 Width3.600 cm
Package 1 Length26.000 cm
Package 1 Weight112.000 g
Unit Type of Package 2S01
Number of Units in Package 240
Package 2 Height15.000 cm
Package 2 Width15.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.670 kg
Unit Type of Package 3P06
Number of Units in Package 31280
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight159.060 kg
The product GV2G554 from Schneider Electric is a three-phase busbar system from the Linergy series, specifically designed as connection accessory for motor protection circuit breakers. It serves for safe and efficient power distribution in industrial installations and is executed as a comb busbar. The busbar is intended for use in switchgear, where multiple devices are to be connected via a common power supply. The construction enables structured and clear wiring, thus facilitating maintenance and servicing.

Applications
This busbar system is intended for use in industrial electrical installations, particularly in combination with motor protection circuit breakers from the TeSys families. It is used in installations where multiple motors or electrical loads are supplied from a common power source, for example in production lines, pump stations or conveyor systems. The busbar is designed for operation in switchboards and enclosures, where compact and reliable power distribution is required.

Functions and Equipment in Detail
The busbar features five outgoing points, each secured via terminals. This enables connection capability for five separate consumers or devices. The mounting is done via terminals, ensuring a secure and mechanically stable connection. The busbar is rated for a conventional thermal current of 63 A in free air, enabling high load capacity for industrial applications. The rated insulation voltage is 690 V, allowing use in high-voltage installations up to this voltage.

Technology Explained Simply
The busbar is designed as a comb busbar, meaning it has a flat, longitudinal conductor structure, where multiple connections are made via terminals. The connection pitch is 54 mm, which is a standard dimension in the electrical industry and ensures compatibility with other components. The width of the busbar is 260 mm, providing sufficient space for the five outgoing points. The thermal rating of 63 A in free air indicates that the busbar is designed for continuous loads without overheating or thermal damage.

Compatibility and Accessories
The device is compatible with the product families TeSys Deca, TeSys GV2, TeSys K, and TeSys U. This compatibility enables integration into existing switchgear installations already using these series. As accessories, motor protection circuit breakers of various types and rated currents can be combined, for example GV2P21, GV2P20, GV2ME08 or GV2LE22, to adapt the switchgear to the specific requirements of the installation. Combining with motor protection circuit breakers enables protection functions such as thermal and magnetic tripping, which are necessary for the safety of connected motors.

Mounting and Installation
Mounting is done via terminals, which are attached at the designated connection points on the busbar. The busbar is installed into the switchgear, where the outgoing points enable connection of individual consumers. Installation does not require special tools, as the terminals are mechanically locked. The connection pitch of 54 mm ensures standardized placement, compatible with other components of the TeSys family.

Advantages in Operation
The use of the busbar system GV2G554 provides clear and organized power distribution, facilitating maintenance and fault diagnosis. The high thermal rating of 63 A and insulation voltage of 690 V enable use in demanding industrial environments. Compatibility with various motor protection circuit breakers allows flexible adaptation to different requirements. The terminal mounting ensures a secure and durable connection, remaining stable even under mechanical stress. The busbar is certified to CE and cULus, confirming compliance with international safety standards.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/560989