| Complementary |
| Product certifications | CE; cULus |
| [Ui] rated insulation voltage | 690 V |
| Connection pitch | 45 mm |
| Width | 89 mm |
| Net weight | 0.036 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Logistical informations |
| Country of origin | RO |
| Main |
| Range | Linergy |
| Product name | FT |
| Device short name | GV2G |
| Product or component type | Comb busbar |
| Accessory / separate part category | Connection accessory |
| Poles description | 3P |
| Range compatibility | TeSys GV2; TeSys Deca; TeSys U |
| Fixing mode | Terminals: |
| Number of tap-offs | 2 |
| [Ith] conventional free air thermal current | 63 A |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2 cm |
| Package 1 Width | 4 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 37 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 100 |
| Package 2 Height | 15 cm |
| Package 2 Width | 15 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 3.862 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 3200 |
| Package 3 Height | 77 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 60 cm |
| Package 3 Weight | 130.9 kg |
The article GV2G245 from Schneider Electric is a
three-phase busbar system from the Linergy series, specifically designed for use with TeSys GV2 family motor protection circuit breakers. It serves as a
comb busbar for safe and efficient power distribution in industrial installations. The system enables parallel supply of multiple devices via a common power busbar, eliminating the need for individual connections. The busbar is rated for a
rated insulation voltage of 690 V and features a
conventional thermal current of 63 A in free air, making it suitable for applications with medium to high loads.
Applications
The busbar system GV2G245 is used in industrial electrical installations, particularly in switchgear, where multiple motor protection circuit breakers or other devices with screw terminal connections are to be connected to a common power busbar. It is compatible with the TeSys GV2, TeSys Deca, and TeSys U product families. The system is intended for use in installations with three-phase power supply, with the busbar designed for
3-pole connections (3P). The connection pitch is
45 mm, matching the standard dimension for TeSys devices. The busbar is designed for
two outgoing points, allowing two separate loads or switches to be connected.
Functions and Equipment in Detail
The comb busbar GV2G245 is secured via
screw terminals, ensuring a safe and mechanically stable connection. The mounting is done directly onto the terminal screws of the motor protection circuit breakers, enabling direct power supply without additional connecting wires. The busbar is designed for a
width of 89 mm, corresponding to the standard width for TeSys devices. The maximum current rating of 63 A in free air allows use in installations with medium to high electrical loads. The busbar is designed for use in switchgear with
MTZ 20, indicating a specific mounting and fastening geometry.
Technology Explained Simply
The comb busbar functions as an electrical distributor, supplying multiple devices via a common power line. This reduces the number of required cable connections, simplifying installation and reducing the risk of errors. The busbar is made of a conductive material that enables efficient power transmission with minimal losses. The rated insulation voltage of 690 V ensures electrical safety at high voltages. The busbar is designed for use in switchgear with a pitch of 45 mm, ensuring standardization and modularity in electrical installations.
Compatibility and Accessories
The busbar system GV2G245 is specifically developed for motor protection circuit breakers from the TeSys GV2 family, but can also be used with TeSys Deca and TeSys U product families. It is intended for devices with screw terminal connections. Suitable accessories include various motor protection circuit breakers such as GV2LE05, GV2LE10, GV2P08, or GV2P22, which can be directly connected to the busbar. Additionally, power contactors from the LC1D series, such as LC1D32C7 or LC1D12T7, can be used in combination with the busbar system, provided they meet the required connection types and pitches.
Mounting and Installation
Mounting is done by direct attachment to the screw terminals of the motor protection circuit breakers. The busbar is inserted into the designated terminals and secured with screws. The connection pitch of 45 mm ensures compatibility with other TeSys devices. The busbar is designed for two outgoing points, allowing two separate loads or switches to be connected. Installation is carried out in switchgear rated for a rated insulation voltage of 690 V.
Operational Advantages
Using the busbar system GV2G245 reduces the number of required cable connections, simplifying installation and easing maintenance. The secure mounting via screw terminals ensures a stable electrical connection. The standardization of the 45 mm pitch enables a modular and clear arrangement of devices in the switchgear. The high current rating of 63 A in free air makes the system suitable for a wide range of industrial applications. The CE and cULus certifications confirm compliance with European and North American safety standards.