| Additional features |
| Control type | Toggle switch |
| Mounting mode | Fixed |
| Mounting bracket | Rear panel |
| Connection on top side | front side |
| Connection on underside | front side |
| Mechanical life | 10000 cycles |
| Terminal pitch | 35 mm |
| Local signalling | Function indicator |
| Neutral conductor protection setting | Without protection |
| Earth fault protection | None |
| Height | 165 mm |
| Width | 105 mm |
| Depth | 60 mm |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | EasyPact |
| Product or component type | Power-cut-out switch |
| Device short name | Easypact EZC250H |
| Power switch designation | Easypact EZC250H |
| Device application | Distribution |
| Pole description | 3P |
| Description of protected poles | 3t |
| Type of network | DC; AC |
| Network frequency | 50/60 Hz |
| [In] Rated current | 175 A at 40 °C |
| [Ui] Rated insulation voltage | 690 V AC 50/60 Hz complies with IEC 60947-2 |
| [Uimp] Rated impulse voltage withstand | 6 kV corresponds to IEC 60947-2 |
| [Ue] Rated operational voltage | 550 V AC 50/60 Hz complies with IEC 60947-2; 250 V DC complies with IEC 60947-2 |
| Breaking capacity | H |
| [Ics] Rated operational breaking capacity | 5 kA at 550 V AC 50/60 Hz corresponds to IEC 60947-2; 15 kA at 125 V DC corresponds to IEC 60947-2; 15 kA at 250 V DC corresponds to IEC 60947-2; 18 kA at 380 V AC 50/60 Hz corresponds to IEC 60947-2; 18 kA at 400/415 V AC 50/60 Hz corresponds to IEC 60947-2; 12.5 kA at 440 V AC 50/60 Hz corresponds to IEC 60947-2; 42.5 kA at 110/130 V AC 50/60 Hz corresponds to IEC 60947-2; 42.5 kA at 220/230/240 V AC 50/60 Hz corresponds to IEC 60947-2 |
| Suitability for insulation | Yes, complies with IEC 60947-2 |
| Application category | Category A |
| Trigger name | TM-D |
| Trigger technology | Thermal-magnetic |
| Trigger power | 175 A at 50 °C |
| Degree of protection | Short-circuit protection; overload protection |
| Pollution degree | 3 corresponds to IEC 60664-1; 3 corresponds to IEC 947-1 |
| Mounting |
| Standards | GB/T 14048.2; EN/IEC 60947-1; EN/IEC 60947-2 |
| Degree of protection (IP) | IP20 complies with IEC 60529 |
| Degree of protection (IK) | IK07 corresponds to IEC 62262 |
| Operating ambient temperature | -25…70 °C |
| Ambient temperature during storage | -35…85 °C |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 11,400 cm |
| VPE 1 width | 11,300 cm |
| VPE 1 length | 18,000 cm |
| Packaging weight (Lbs) | 1,640 kg |
| VPE 2 type | S03 |
| VPE 2 quantity | 8 |
| VPE 2 height | 30,000 cm |
| VPE 2 width | 30,000 cm |
| VPE 2 length | 40,000 cm |
| VPE 2 weight | 13,607 kg |
The EZC250H3175 circuit breaker from Schneider Electric belongs to the EasyPact series and is designed as a 3-pole switch (3P) with 3-pole protection function (3t). It is intended for use in electrical distribution systems and provides thermomagnetic protection via the TM-D tripping unit. The switch is rated for operating voltages of 550 V AC (50/60 Hz) and 250 V DC, and complies with standards IEC 60947-1 and IEC 60947-2. The rated insulation voltage is 690 V AC, and the rated impulse voltage withstand is 6 kV. The rated operational breaking capacity ranges from 5 kA to 42.5 kA depending on the voltage range, with the switch certified for various network conditions. The rated current is 175 A at an ambient temperature of 40 °C, and the tripping unit rating is 175 A at 50 °C. The application category is A, indicating suitability for installations requiring high safety standards.
Applications
This circuit breaker is suitable for use in industrial and commercial distribution systems, particularly in installations requiring high reliability and safety. It can be mounted vertically or horizontally in metal enclosures and is certified for environments with pollution degree 3 (according to IEC 60664-1 and IEC 60947-1). The operating ambient temperature ranges from -25 °C to 70 °C, and the storage temperature ranges from -35 °C to 85 °C. The protection rating is IP20, providing protection against contact with fingers and against solid foreign objects larger than 12.5 mm. The mechanical life expectancy is 10,000 cycles, indicating high durability.
Functions and Equipment in Detail
The switch features a toggle switch as the control type and is designed for fixed mounting on a back panel. Connections are located on the front side, with a connection pitch of 35 mm. Local signaling is provided by a function indicator that visually displays the operating status. Protection includes short-circuit protection and overload protection; the neutral conductor is not protected, and no earth fault protection is integrated. Dimensions are 105 mm (width), 165 mm (height), and 60 mm (depth). The protection rating IP40 applies to the direct rotary handle, while IP54 applies to the extended rotary handle, enabling a higher protection class under increased environmental stress.
Technology Explained Simply
The thermomagnetic tripping unit TM-D combines thermal and magnetic components to respond to both slowly increasing overloads and sudden short circuits. The thermal component reacts to continuous overloads, while the magnetic component responds to sudden current surges. Breaking capacities vary depending on the voltage range, and the switch is designed for different networks (AC/DC) and frequencies (50/60 Hz). The rated operating voltage of 550 V AC and 250 V DC allows flexible integration into various installations. The IP20 protection rating safeguards against finger contact and larger foreign objects, while the IK07 rating provides protection against mechanical impacts such as shocks or vibrations.
Compatibility and Accessories
Various accessories are available for this circuit breaker, including the rotary handle for EZC250 (EZEROTE EZCV250 black with black front plate), which enables more ergonomic operation. Other compatible products include the LV525302 circuit breaker (EasyPact CVS250B) and the EZESHT200AC (EZ250 mx 200/240 VAC), which can be combined in installations according to specific requirements. The device’s socket positions allow integration of auxiliary devices for voltage isolation, enhancing safety during maintenance work.
Mounting and Installation
The switch is designed for fixed mounting on a back panel and can be installed vertically or horizontally in metal enclosures. Mounting is done using the standard 35 mm pitch. Before installation, it is essential to ensure that all power supplies are switched off and secured. The use of padlocks to prevent unauthorized access is recommended. Connections are made on the front side, and correct polarity along with compliance with electrical standards (such as EN/IEC 60947-1 and -2) is mandatory.
Operational Advantages
The circuit breaker offers high reliability due to its thermomagnetic tripping technology and a long service life of 10,000 operating cycles. The clear function indicator simplifies monitoring of the operating status. Compatibility with various accessories and the ability to integrate auxiliary devices increase operational flexibility and safety. Certification to IEC 60947-2 and CE marking guarantee compliance with international safety and quality standards. The IP20 and IK07 protection ratings ensure safe operation in industrial environments with increased stress.