| Complementary |
| Range compatibility | EVlink EcoStruxure EV Charging Expert; EVlink EVlink Pro AC Metal; EcoStruxure EcoStruxure EV Advisor |
| Type of installation | Indoor; Outdoor |
| Provided equipment | 1 residual direct current detection device (RDC-DD) integrated; 1 energy meter integrated; 1 MID meter integrated; 1 badge |
| Accuracy class of energy meter | Class 1 |
| Protection device type | Residual direct current detection device (RDC-DD) - 6 mA |
| Poles description | 3P + N for power circuit |
| Mounting mode | Wall-mounted; Wall-mounted (kit enclosure); Floor-standing (pedestal); Floor-standing (kit enclosure) |
| Mounting support | Pedestal, to be ordered separately; Kit enclosure, to be ordered separately |
| cable entry | Bottom entry; Top entry; Rear entry |
| [Us] rated supply voltage | 380...415 V AC 50/60 Hz |
| Nominal output power | 22 kW 32 A 380...415 V |
| Socket number | 1 |
| Output type | Front side T2 with shutter socket-outlet / silver plated contacts |
| Access control system | Badge RFID conforming to ISO/IEC 14443 A and B; Badge RFID conforming to ISO/IEC 15693; Badge NFC; Free access |
| RFID compatible technology | MIFARE Classic; MIFARE Ultralight; MIFARE Plus |
| NFC frequency | 13.56 MHz |
| NFC tag type | Type 1; Type 2; Type 4; Type 5 |
| Earthing system | TT; TN-S; TN-C-S; IT (single phase network only allowed, 400V 3 phases network forbidden) |
| Condition of use | 3x230VAC (ph-ph) distribution forbidden |
| Number of inputs | 3 |
| Input type | Binary for power limitation closing contact; Binary for delayed charging closing contact; Binary for vehicle detection closing contact |
| Control type | can be controlled by remote |
| Local signalling | 1 green LED light strip, function: available; 1 blue LED light strip, function: charging; 1 red LED light strip, function: fault indication |
| Standards | EN/IEC 61851-1:ed. 3; EN/IEC 62196-1:ed. 2; EN/IEC 62196-2:ed. 1; EN 61000-6-2:2019; EN 61000-6-3:2007; EN 61000-6-3:2011/A1; IEC 60884-1; NF C 61314; ISO 15118 |
| Product certifications | EV Ready; CE |
| Operating altitude | 2000 m without derating |
| Height | 529 mm |
| Width | 317 mm |
| Depth | 153 mm |
| Net weight | 7.2 kg |
| Colour | Front face: white (RAL 9003); Housing: dark grey (RAL 7016); Back part: black (RAL 9005) |
| Contractual warranty |
| Warranty (in months) | 24 |
| Environment |
| IP degree of protection | IP55 |
| IK degree of protection | IK10 |
| Ambient air temperature for operation | -30…50 °C |
| Ambient air temperature for storage | -40…80 °C |
| Relative humidity | 5…95 % |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | EVlink |
| Product name | EVlink Pro AC |
| Product or component type | Charging station |
| Device short name | EVB3 |
| Directives | 2014/32/EU - measuring instruments directive (MID) |
| Communication network type | Ethernet; Bluetooth; 3G/4G modem optional; Modbus TCP |
| Connector type | 2 RJ45 for Ethernet LAN connection |
| Communication port protocol | OCPP 1.6 |
| Communication service | JSON smart charging for OCPP 1.6 |
| Operating mode | Clustered architecture; Standalone |
| Function available | Diagnosis capabilities; Charge detail records; Load management |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 28.000 cm |
| Package 1 Width | 35.700 cm |
| Package 1 Length | 57.500 cm |
| Package 1 Weight | 8.489 kg |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 71.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 41.000 kg |
EVlink Pro AC wallbox with type 2 socket with shutters. For use in semi-public garages or parking lots, for indoor or outdoor installation on the wall, on the EVlink stele (EVA1PBS1 / EVA1PBS2) or in the metal kit (EVA1RWKS1 / EVA1RFKS1 / EVA1RFKS2). Mode 3 charging according to IEC 61851-1, 3-phase with maximum 22 kW charging power, type 2 socket. with integrated MID meter 3-phase, 6mA DC residual current detection (enables the use of a type A FI). Digital inputs: 1 for temporary current limitation, 1 for postponed/suspended charging, 1 for EV presence detection. Access controller via NFC / RFID reader. NFC reader 13.56 MHz compatible with type 1, 2, 4 and 5 badges, RFID reader: Complies with the protocols ISO/CEI 14443 A &, B and ISO/CEI 15693, Compatible with Mifare Ultralight, Mifare Classic, Mifare Plus. User information and status message via a clearly visible LED arch, commissioning of the wallbox via eSetup app via Bluetooth. Communication standards: Bluetooth, Ethernet 2 ports (1 for daisy chain), Modbus serial, Modbus TCP, OCPP 1.6J for connection to a backend and the load management system EcoStruxure EV Charging Expert. Optional accessories: WiFi module (EVA1MW), modem module (EVA1MS &, EVA1MM), ISO 15118 module (EVA1M8), can be plugged into the charging controller. Color of the charging station: Body: dark gray RAL 7016 and black RAL 9005, front cover: white RAL 9003. Dimensions WxHxD: 317x529x153mm, weight: 7.5 kg, material: UV-treated polycarbonate. Shock resistance IK10, protection class IP55, operating temperature -30 to 50°C, storage temperature -40 to 80°C, operating altitude max. 2000m without derating, relative humidity 5 to 95%, own consumption <10W. Earthing system: TT, TN(S) or TN(C)(S), IT compatible with additional isolation transformer in the power supply. Norms and standards: CE, EV Ready, IEC/EN 61851-1 Ed 3.0, IEC/EN 62196-1 Ed 2.0, IEC/EN 62196-2 Ed 1.0, EN 61000-6-2: 2019, EN 61000-6-3:2007 + A1:2011, IEC 60884-1 and NF-C 61314.