Schneider Electric CAD50AV7, EAN: 3606487541646

Schneider Electric CAD50AV7 auxiliary contactor 5S coil 400 V 50/60 Hz SnapIN

Schneider Electric CAD50AV7 auxiliary contactor 5S coil 400 V 50/60 Hz SnapIN

Lieske Part No. 807780
Mfg Part No CAD50AV7
EAN-Code 3606487541646
Manufacturer Schneider Electric
Here only 46,79 EUR
55,68 EUR incl. VAT

Further information for Schneider Electric CAD50AV7 auxiliary contactor 5S coil 400 V 50/60 Hz SnapIN

Additional features
Application categoryAC-15; AC-14; DC-13
Composition of pole contact5 NO
Control circuit typeAC 50/60 Hz
[Uc] control circuit voltage400 V AC 50/60 Hz
[Uimp] Rated impulse voltage withstand6 kV corresponds to IEC 60947
[Ith] conventional thermal current in free air10 A (at 60 °C)
[Irms] Rated making capacity140 A AC; 250 A DC
[Icw] rated short-time current withstand100 A - 1 s; 120 A - 500 ms; 140 A - 100 ms
Associated fuse10 A gG according to IEC 60947-5-1
[Ui] Rated insulation voltage690 V corresponds to IEC 60947-5-1
Mounting bracketRail; Plate
Connections - terminalsSnap-in terminal 1 cable(s) 0.5…4 mm² flexible without cable end; Snap-in terminal 2 cable(s) 0.5…4 mm² flexible without cable end; Snap-in terminal 1 cable(s) 0.5…2.5 mm² flexible with cable end; Snap-in terminal 2 cable(s) 0.5…2.5 mm² flexible with cable end
Control circuit voltage limits0.3 - 0.6 Uc (-40…70 °C): drop-out voltage AC 50/60 Hz; 0.8 - 1.1 Uc (-40…60 °C): operation AC 50 Hz; 0.85 - 1.1 Uc (-40…60 °C): operation AC 60 Hz; 1 - 1.1 Uc (60…70 °C): operation AC 50/60 Hz
Operating time4 - 19 ms coil energization and NC opening; 12 - 22 ms coil energization and NO closing; 4 - 12 ms coil de-energization and NO opening; 6 - 17 ms coil de-energization and NC closing
Mechanical life30 Mcycles
Max. operating rate180 cyc/mn
Input power in VA70 VA 50 Hz (at 20 °C)
Hold power consumption in VA8 VA 50 Hz (at 20 °C)
Min. switching voltage17 V
Min. switching current5 mA
Non-overlapping time1.5 ms when actuated between normally open contact and normally closed contact; 1.5 ms when de-energized between normally open contact and normally closed contact
Insulation resistance> 10 MΩ
Mechanical robustnessShocks control relay open: 10 Gn for 11 ms according to IEC 60068-2-27; Shocks control relay closed: 15 Gn for 11 ms according to IEC 60068-2-27; Vibrations control relay open: 2 Gn, 5 - 300 Hz according to IEC 60068-2-6; Vibrations control relay closed: 4 Gn, 5 - 300 Hz according to IEC 60068-2-6
Height107 mm
Width45 mm
Depth93 mm
Product weight387 g
Contractual warranty
Warranty (in months)18
Main features
Product seriesTeSys
Product nameTeSys CAD
Product or component typeControl relay
Device short nameCAD
Application of contactorControl circuit
Mounting
StandardsEN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No. 60947-5-1; GB/T 14048.5; JIS C8201-5-1
Product certificationsCB control; CCC; cULus; CE; UKCA; EU-RO-MR by DNV
Degree of protection (IP)IP2x front panel complies with VDE 0106
CoatingTH corresponds to IEC 60068
Operating ambient temperature-40…60 °C; 60…70 °C with power reduction
Ambient temperature during storage-60…80 °C
Operating altitude0 - 3.000 m
Packaging units
VPE 1 typePCE
Number of devices per package1
VPE 1 height5 cm
VPE 1 width10,5 cm
VPE 1 length11,5 cm
Packaging weight (Lbs)407 g
VPE 2 typeS02
VPE 2 quantity15
VPE 2 height15 cm
VPE 2 width30 cm
VPE 2 length40 cm
VPE 2 weight6,42 kg
VPE 3 typeP06
VPE 3 quantity240
VPE 3 height75 cm
VPE 3 width60 cm
VPE 3 length80 cm
VPE 3 weight111,22 kg