| Complementary |
| Utilisation category | DC-13; AC-15; AC-14 |
| Pole contact composition | 3 NO + 2 NC |
| Control circuit type | DC standard |
| [Uc] control circuit voltage | 24 V DC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1 |
| [Icw] rated short-time withstand current | 100 A - 1 s; 120 A - 500 ms; 140 A - 100 ms |
| Associated fuse rating | 10 A gG conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 600 V UL certified; 600 V CSA certified; 690 V conforming to IEC 60947-5-1 |
| Mounting support | Rail; Plate |
| Connections - terminals | Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end; Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end; Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end; Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end; Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end |
| Tightening torque | 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2; 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm; 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Control circuit voltage limits | 0.1...0.25 Uc (-40…70 °C):drop-out DC; 0.7...1.25 Uc (-40…60 °C):operational DC; 1...1.25 Uc (60…70 °C):operational DC |
| Operating time | 53...72 ms coil energisation and NO closing; 16...24 ms coil de-energisation and NO opening; 47...63 ms coil energisation and NC opening; 15...25 ms coil de-energisation and NC closing |
| Mechanical durability | 30 Mcycles |
| Maximum operating rate | 180 cyc/mn |
| Time constant | 28 ms |
| Inrush power in W | 5.4 W (at 20 °C) |
| Hold-in power consumption in W | 5.4 W at 20 °C |
| Minimum switching voltage | 17 V |
| Minimum switching current | 5 mA |
| Non-overlap time | 1.5 ms on energisation between NC and NO contact; 1.5 ms on de-energisation between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Mechanical robustness | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 93 mm |
| Net weight | 0.58 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-5-1; GB/T 14048.5; UL 60947-5-1; CSA C22.2 No 60947-5-1; JIS C8201-5-1 |
| Product certifications | CB; CCC; UL; CSA; EAC; CE; UKCA |
| IP degree of protection | IP2X front face conforming to VDE 0106 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -40…60 °C; 60…70 °C with derating |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 0...3000 m |
| Logistical informations |
| Country of origin | FR |
| Main |
| Range | TeSys; TeSys Deca |
| Product name | TeSys CAD |
| Product or component type | Control relay |
| Device short name | CAD |
| Contactor application | Control circuit |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.200 cm |
| Package 1 Width | 9.400 cm |
| Package 1 Length | 11.400 cm |
| Package 1 Weight | 521.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 15 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.108 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 240 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 137.730 kg |
The
control relay CAD32BD from the
TeSys Deca series by
Schneider Electric is an
auxiliary contactor designed for use in control circuits. It operates at
24 V DC and features five integrated auxiliary contacts configured as
3 NO + 2 NC (3 normally open, 2 normally closed). The device is designed for use in industrial applications, where it is employed for signal transmission, controlling auxiliary functions, or interlocking switching operations. The
screw terminals allow connection with flexible or rigid cables in cross-sections from 1 to 4 mm²; for flexible cables with wire end ferrules, a cross-section of 1 to 2.5 mm² is also permitted. Mounting is either on a
rail or directly onto a
plate, with a device width of 45 mm.
Applications include control of drives, machine controls, safety functions, and other electrical switching operations in industrial environments. The device is designed for use in environments with an operating temperature range of
-40 °C to 60 °C; at temperatures from 60 °C to 70 °C, a derating is required. Storage is possible in the range of
-60 °C to 80 °C. The operating altitude is up to
3,000 m above sea level. The front-side protection rating
IP2x protects against finger contact and offers some protection against solid objects, but not against water. The coating corresponds to category
TH according to IEC 60068, indicating high resistance to humidity and temperature fluctuations.
Functions and features in detail include an integrated protective circuitry ensuring safe and reliable operation. The
rated transient voltage withstand is 6 kV, ensuring high electrical strength under transient voltage stress. The
rated insulation voltage is 690 V according to IEC 60947-5-1, with additional certifications for 600 V UL and CSA. The
rated switching capacity is specified as 140 A for AC and 250 A for DC, enabling use in high-performance systems. The
rated short-time withstand current is 100 A for 1 second, 120 A for 500 ms, and 140 A for 100 ms. The associated fuse protection is defined as
10 A gG according to IEC 60947-5-1.
Technology explained simply shows that the device operates with a
control circuit voltage of 24 V DC, with the operating voltage required to be between 0.7 and 1.25 times the nominal voltage (at -40 °C to 60 °C). The minimum switching voltage is 17 V, and the minimum switching current is 5 mA. The
coil pickup power and
holding power consumption are each 5.4 W at 20 °C. The
operating time is 53 to 72 ms for coil energization and closing of NO contacts, and 16 to 24 ms for de-energization and opening of NO contacts. The
mechanical life is 30 million switching cycles, with a maximum operating rate of 180 operations per minute. The
non-overlapping time between normally open and normally closed contacts is 1.5 ms, ensuring safe contact separation. The
insulation resistance is greater than 10 MΩ, ensuring high electrical insulation.
Compatibility and accessories include the option to extend the device with additional auxiliary contacts. Expansion by up to nine additional auxiliary contacts is possible, with compatible auxiliary contact blocks such as
LADN13 (1S3Ö),
LADN22 (2S2Ö), or
LA1DZ40 (4S) available. Additional components such as
protective covers (e.g. LAD9ET1S),
time blocks (e.g. LADT4), or
interlocking blocks (e.g. LAD6K10F) can be added to meet specific requirements. Mounting is via screw or snap fastening, with a tightening torque of 1.7 Nm for the screw terminals.
Mounting and installation is on a standard rail (e.g. DIN rail) or directly onto a mounting plate. The device dimensions are 45 mm width, 77 mm height, and 93 mm depth. The product weight is 0.58 kg. Installation is simple and performed with a screwdriver (Phillips No. 2, flat Ø 6 or position No. 2). Mechanical robustness is specified according to IEC 60068-2-27 and IEC 60068-2-6, allowing shocks of 10 Gn (open) or 15 Gn (closed), and vibrations of 2 Gn (open) or 4 Gn (closed) in the frequency range of 5 to 300 Hz.
Operational advantages include high mechanical life, high switching capacity, easy mounting, and expandability. The integrated protective circuitry ensures reliable operation even under demanding operating conditions. Certifications according to
EN/IEC 60947-5-1,
UL 60947-5-1,
CSA C22.2 No. 60947-5-1, and other standards guarantee compliance with international standards. The usage categories
DC-13,
AC-15, and
AC-14 define the operating conditions for DC and AC applications. The device is therefore suitable for a wide range of industrial control tasks, particularly in systems with high switching frequencies and demanding environmental conditions.