| Complementary |
| Utilisation category | AC-15; AC-14; DC-13 |
| Pole contact composition | 3 NO + 2 NC |
| Control circuit type | AC 50/60 Hz |
| [Uc] control circuit voltage | 48 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| [Ith] conventional free air thermal current | 10 A (at 60 °C) |
| Irms rated making capacity | 140 A AC; 250 A DC |
| [Icw] rated short-time withstand current | 100 A - 1 s; 120 A - 500 ms; 140 A - 100 ms |
| Associated fuse rating | 10 A gG conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 |
| Mounting support | Rail; Plate |
| Connections - terminals | Snap-in terminal 1 cable(s) 0.5…4 mm²flexible without cable end; Snap-in terminal 2 cable(s) 0.5…4 mm²flexible without cable end; Snap-in terminal 1 cable(s) 0.5…2.5 mm²flexible with cable end; Snap-in terminal 2 cable(s) 0.5…2.5 mm²flexible with cable end |
| Control circuit voltage limits | 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz; 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz; 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz; 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Operating time | 12...22 ms coil energisation and NO closing; 4...12 ms coil de-energisation and NO opening; 4...19 ms coil energisation and NC opening; 6...17 ms coil de-energisation and NC closing |
| Mechanical durability | 30 Mcycles |
| Maximum operating rate | 180 cyc/mn |
| Inrush power in VA | 70 VA 50 Hz (at 20 °C) |
| Hold-in power consumption in VA | 8 VA 50 Hz (at 20 °C) |
| Minimum switching voltage | 17 V |
| Minimum switching current | 5 mA |
| Non-overlap time | 1.5 ms on energisation between NC and NO contact; 1.5 ms on de-energisation between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Mechanical robustness | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27; Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27; Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6; Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Height | 107 mm |
| Width | 45 mm |
| Depth | 93 mm |
| Net weight | 387 g |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; JIS C8201-5-1 |
| Product certifications | CB Scheme; CCC; cULus; CE; UKCA; EU-RO-MR by DNV |
| IP degree of protection | IP2X front face conforming to VDE 0106 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -40…60 °C; 60…70 °C with derating |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 0...3000 m |
| Main |
| Range | TeSys |
| Product name | TeSys CAD |
| Product or component type | Control relay |
| Device short name | CAD |
| Contactor application | Control circuit |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.500 cm |
| Package 1 Width | 5.500 cm |
| Package 1 Length | 11.500 cm |
| Package 1 Weight | 411.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 15 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.441 kg |
Hilfsschütze TeSys Control CAD. Hilfsschütz für die Gebrauchskategorien AC-15 bis 690V und DC-13 bis 440V. Es bietet 5 Kontakte (3S + 2Ö), eine 48 V 50/60Hz AC Spule. Für anspruchsvolle Anwendungen mit hohen Betriebsgeschwindigkeiten bis zu 10800 Zyklen/Stunde sorgt er für hohe Zuverlässigkeit und Haltbarkeit. Fünf integrierte Hilfskontakte, erweiterbar um bis zu neun Hilfskontakte. Schnelle, sichere und wartungsfreie Stromverbindung mit SnapIN Anschlussklemme. Geeignet für Sicherheitsanwendungen durch mechanisch gekoppelte Kontakte und Spiegelkontakte.