| Additional features |
| [Ui] Rated insulation voltage | 500 V AC 50/60 Hz |
| [Uimp] Rated impulse voltage withstand | 8 kV |
| [Ics] Rated operational short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz complies with IEC 60947-2; 36 kA at 380/415 V AC 50/60 Hz complies with IEC 60947-2; 35 kA at 440 V AC 50/60 Hz complies with IEC 60947-2; 12 kA at 500 V AC 50/60 Hz complies with IEC 60947-2; 11 kA at 525 V AC 50/60 Hz complies with IEC 60947-2; 4 kA at 660/690 V AC 50/60 Hz complies with IEC 60947-2 |
| Mechanical life | 50000 cycles |
| Electrical lifetime | 50,000 cycles at 440 V In/2; 30,000 cycles at 440 V In; 20,000 cycles at 690 V In/2; 10,000 cycles at 690 V In |
| Power dissipation per pole | 5.8 W N; 5.8 W L1 and L3; 4.9 W L2 |
| Mounting bracket | Rear panel |
| Mounting position | Horizontal and vertical; lying on back |
| Connection on top side | front side |
| Connection on underside | front side |
| Terminal pitch | 35 mm |
| Degree of protection | L: for overload protection (long-time); S: for short-time short-circuit protection; I: for instantaneous short-circuit protection; R: for earth fault protection |
| Trigger power | 40 A at 40 °C |
| [Ir] type of long-time pickup setting (thermal protection) | 9 adjustable settings |
| [Ir] Long-time protection pick-up adjustment range | 18 - 40 A |
| [tr] Type of long-time protection delay adjustment | Adjustable |
| [tr] adjustable long-time delay range | 15…400 s at 1.5 x Ir; 0.5…16 s at 6 x Ir; 0.35…11 s at 7.2 x Ir |
| Neutral protection settings | 0.5 x Ir (3d + N/2); 1 x Ir (4D); No protection (3D) |
| Thermal storage | 20 minutes before and after tripping |
| [Isd] type of short-time protection setting | Adjustable |
| [Isd] Short-time protection adjustment range | 1,5 - 10 x Ir |
| [tsd] Type of short-time protection delay adjustment | Adjustable |
| [tsd] Short-time delay adjustment range | 0…0.4 s I²t=off; 0.1…0.4 s I²t=on |
| [Ii] type of instantaneous short-circuit protection setting | Adjustable |
| [Ii] setting range of instantaneous short-circuit protection | 1,5 - 15 x In |
| Earth fault protection | Integrated |
| Earth fault protection class | Class A |
| [IΔn] type of residual current protection sensitivity setting | Adjustable |
| [IΔn] setting range of sensitivity for residual current protection | 30 mA; 100 mA; 300 mA; 500 mA; 1 A; 3 A; 5 A |
| Specific mode for earth fault protection | Off with the rotary switch ΙΔn |
| [Δt] Type of residual current protection time delay adjustment | Adjustable |
| [Δt] Adjustment range for earth fault protection time delay | 0 ms; 60 ms; 150 ms; 500 ms; 1 s |
| Zoneselective interlock ZSI | None |
| Number of sockets for electrical auxiliary devices | 5 socket (sockets) |
| Local signalling | Blinking LED (green) for ready; LED 105 % Ir (red) for overload; LED 90 % Ir (orange) for overload |
| Display type | LCD display |
| Measured value type | Energy meter |
| Data transmission | Time-stamped trends and event logs; maintenance alerts; instantaneous and requested values; max/min meters; protection and alarm settings; power supply quality; energy consumption measurement; current and line query |
| Width (B) | 140 mm |
| Height (H) | 161 mm |
| Depth (T) | 86 mm |
| Product weight | 2,4 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Main features |
| Product series | ComPacT |
| Product name | ComPacT NSX |
| Device short name | NSX100F |
| Product or component type | Earth fault circuit breaker |
| Device application | Distribution |
| Pole description | 4P |
| Description of protected poles | 4D; 3D + OSN; 3d + N/2; 3D |
| Neutral position | Left |
| [In] Rated current | 40 A at 40 °C |
| [Ue] Rated operational voltage | 440 V AC 50/60 Hz |
| Type of network | AC |
| Network frequency | 50/60 Hz |
| Suitability for insulation | Yes, complies with EN/IEC 60947-2 |
| Application category | Category A |
| Power class | F 36 kA 415 V AC |
| Trigger name | MicroLogic 7.2 E |
| Trigger technology | Electronic |
| Tripping unit protection functions | LSIR |
| Control type | Toggle switch |
| Mounting type of power switch | Fixed |
| Mounting |
| Standards | EN/IEC 60947-2 |
| Over voltage category | IV |
| Protection class for electric shocks | Class II on front |
| Pollution degree | 3 entspricht IEC 60664-1 |
| Degree of protection (IP) | IP40 complies with IEC 60529 |
| Degree of protection (IK) | IK07 corresponds to IEC 62262 |
| Operating ambient temperature | -25…70 °C |
| Ambient temperature during storage | -40…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0 - 2,000 m without power reduction; 2,000 - 5,000 m with power reduction |
| Packaging units |
| VPE 1 type | PCE |
| Number of devices per package | 1 |
| VPE 1 height | 14 cm |
| VPE 1 width | 15 cm |
| VPE 1 length | 19 cm |
| Packaging weight (Lbs) | 2,79 kg |
| VPE 2 type | S03 |
| VPE 2 quantity | 6 |
| VPE 2 height | 30 cm |
| VPE 2 width | 30 cm |
| VPE 2 length | 40 cm |
| VPE 2 weight | 16,74 kg |