| Complementary |
| Electrical connection | Control: screw terminal 0.5...1.5 mm²/20 AWG...16 AWG; Line side: screw terminal 35...50 mm²/2 AWG...1 AWG; Motor: screw terminal 35...50 mm²/2 AWG...1 AWG; DC bus: screw terminal 35...50 mm²/2 AWG...1 AWG |
| Transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
| Exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
| Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
| Type of polarization | No impedance for Modbus serial |
| Number of addresses | 1…247 for Modbus serial |
| Supply | External supply for digital inputs: 24 V DC (19…30 V) |
| Local signalling | Local diagnostic: 3 LED (mono/dual colour); Presence of voltage: 1 LED (red); Embedded communication status: 3 LED (dual colour); Communication module status: 4 LED (dual colour) |
| Input compatibility | DI1...DI8: discrete input level 1 PLC conforming to IEC 61131-2; DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
| Discrete input logic | Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1); Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI8) - discrete input; 5 ms +/- 1 ms (DI7, DI8) - pulse input; 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 5 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Isolation | Between power and control terminals |
| Discrete input number | 10 |
| Discrete input type | DI1...DI8 programmable, 24 V DC ( |
| Discrete output number | 2 |
| Discrete output type | Logic output DQ+ 0…1 kHz |
| Analogue input number | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Physical interface | Ethernet; 2-wire RS 485 |
| Connector type | 2 RJ45; 1 RJ45 |
| Method of access | Slave Modbus TCP |
| Transmission frame | RTU |
| 4 quadrant operation possible | True |
| Asynchronous motor control profile | Optimized torque mode; Constant torque standard; Variable torque standard |
| Synchronous motor control profile | Permanent magnet motor; Synchronous reluctance motor |
| Maximum output frequency | 599 Hz |
| Acceleration and deceleration ramps | S, U or customized; Linear adjustable separately from 0.01...9999 s |
| Motor slip compensation | Can be suppressed; Automatic whatever the load; Not available in permanent magnet motor law; Adjustable |
| Switching frequency | 1...4.9 kHz adjustable; 2.5...4.9 kHz with derating factor |
| Nominal switching frequency | 2.5 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | True |
| Line current | 82.7 A at 500 V (normal duty); 71.0 A at 500 V (heavy duty); 87.7 A at 690 V (normal duty); 68.5 A at 690 V (heavy duty) |
| Maximum input current | 87.7 A |
| Maximum output voltage | 690.0 V |
| Apparent power | 104.8 kVA at 690 V (normal duty); 81.9 kVA at 690 V (heavy duty) |
| Maximum transient current | 99.6 A during 60 s (normal duty); 99 A during 60 s (heavy duty) |
| Network frequency | 50...60 Hz |
| Prospective line Isc | 70 kA |
| Base load current at high overload | 66.0 A |
| Base load current at low overload | 83.0 A |
| Power dissipation in W | Forced convection: 1075 W at 500 V, switching frequency 2.5 kHz; Natural convection: 268 W at 500 V, switching frequency 2.5 kHz |
| With safety function Safely Limited Speed (SLS) | True |
| With safety function Safe brake management (SBC/SBT) | True |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | True |
| With sft fct Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | True |
| With safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Protection type | Thermal protection: motor; Safe torque off: motor; Motor phase break: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive |
| Quantity per set | 1 |
| Width | 331 mm |
| Height | 630 mm |
| Depth | 297 mm |
| Net weight | 53 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
| Noise level | 56 dB conforming to 86/188/EEC |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Environmental characteristic | Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3; Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -15…50 °C (without derating); 50…60 °C (with derating factor) |
| Operating position | Vertical +/- 10 degree |
| Product certifications | CSA; TÜV; UL |
| Marking | CE |
| Standards | UL 508C; IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1 |
| Assembly style | Enclosed |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
| Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Volume of cooling air | 406 m3/h |
| Overvoltage category | III |
| Regulation loop | Adjustable PID regulator |
| Pollution degree | 2 |
| Ambient air transport temperature | -40…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Logistical informations |
| Country of origin | IN |
| Main |
| Range of product | Altivar Process ATV900 |
| Product specific application | Process for industrial |
| Product or component type | Variable speed drive |
| Variant | With braking chopper; Standard version |
| Device application | Industrial application |
| Product destination | Asynchronous motors; Synchronous motors |
| Network number of phases | 3 phases |
| Mounting mode | Wall mount |
| Continuous output current | 83 A at 2.5 kHz for normal duty; 66 A at 2.5 kHz for heavy duty |
| Communication port protocol | Modbus serial; Modbus TCP; EtherNet/IP |
| [Us] rated supply voltage | 500...690 V - 15...10 % |
| Relative symmetric mains voltage tolerance | 10 % |
| Relative symmetric network frequency tolerance | 5 % |
| nominal output current | 83.0 A |
| Motor power kW | 55.0 kW for normal duty; 45.0 kW for heavy duty |
| EMC filter | Integrated; With EMC plate option |
| IP degree of protection | IP21 |
| Degree of protection | UL type 1 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 58.000 cm |
| Package 1 Width | 43.000 cm |
| Package 1 Length | 111.000 cm |
| Package 1 Weight | 48.000 kg |