Schneider Electric ATV930D18M3, EAN: 3606480883637

Schneider Electric ATV930D18M3 frequency converter 18 kW 200/240 V

Industrial Material > Automation > Frequency converter, soft starter

Schneider Electric ATV930D18M3 frequency converter 18 kW 200/240 V

Lieske Part No. 1853451
Mfg Part No ATV930D18M3
EAN-Code 3606480883637
Manufacturer Schneider Electric
Here only 3.803,80 EUR
4.526,52 EUR incl. VAT

Further information for Schneider Electric ATV930D18M3 frequency converter 18 kW 200/240 V

Complementary
Electrical connectionControl: screw terminal 0.5...1.5 mm²/20 AWG...16 AWG; DC bus: screw terminal 25...50 mm²/4 AWG...1 AWG; Line side: screw terminal 35...50 mm²/3 AWG...1 AWG; Motor: screw terminal 35...50 mm²/3 AWG...1 AWG
Transmission rate10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format8 bits, configurable odd, even or no parity for Modbus serial
Type of polarizationNo impedance for Modbus serial
Number of addresses1…247 for Modbus serial
SupplyExternal supply for digital inputs: 24 V DC (19…30 V)
Local signallingLocal diagnostic: 3 LED (mono/dual colour); Embedded communication status: 5 LED (dual colour); Communication module status: 2 LED (dual colour); Presence of voltage: 1 LED (red)
Input compatibilityDI1...DI8: discrete input level 1 PLC conforming to IEC 61131-2; DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logicPositive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1); Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
Sampling duration2 ms +/- 0.5 ms (DI1...DI8) - discrete input; 5 ms +/- 1 ms (DI7, DI8) - pulse input; 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 5 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
IsolationBetween power and control terminals
Discrete input number10
Discrete input typeDI1...DI8 programmable, 24 V DC (
Discrete output number2
Discrete output typeLogic output DQ+ 0…1 kHz
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay output number3
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Physical interfaceEthernet; 2-wire RS 485
Connector type2 RJ45; 1 RJ45
Method of accessSlave Modbus TCP
Transmission frameRTU
4 quadrant operation possibleTrue
Asynchronous motor control profileVariable torque standard; Optimized torque mode; Constant torque standard
Synchronous motor control profilePermanent magnet motor; Synchronous reluctance motor
Maximum output frequency599 Hz
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Motor slip compensationAutomatic whatever the load; Adjustable; Can be suppressed; Not available in permanent magnet motor law
Switching frequency2...16 kHz adjustable; 4...16 kHz with derating factor
Nominal switching frequency4 kHz
Braking to standstillBy DC injection
Brake chopper integratedTrue
Line current66.7 A at 200 V (normal duty); 53.1 A at 200 V (heavy duty); 54.5 A at 240 V (normal duty); 44.9 A at 240 V (heavy duty)
Maximum input current66.7 A
Maximum output voltage240.0 V
Apparent power22.7 kVA at 240 V (normal duty); 18.7 kVA at 240 V (heavy duty)
Maximum transient current94.1 A during 60 s (normal duty); 95.1 A during 60 s (heavy duty)
Network frequency50...60 Hz
Prospective line Isc50 kA
Base load current at high overload63.4 A
Base load current at low overload78.4 A
Power dissipation in WNatural convection: 97 W at 200 V, switching frequency 4 kHz; Forced convection: 595 W at 200 V, switching frequency 4 kHz
With safety function Safely Limited Speed (SLS)True
With safety function Safe brake management (SBC/SBT)True
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)True
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)True
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeThermal protection: motor; Safe torque off: motor; Motor phase break: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive
Quantity per set1
Width226 mm
Height673 mm
Depth274 mm
Net weight27.3 kg
Contractual warranty
Warranty (in months)18
Environment
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level71.5 dB conforming to 86/188/EEC
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Environmental characteristicChemical pollution resistance class 3C3 conforming to IEC 60721-3-3; Dust pollution resistance class 3S3 conforming to IEC 60721-3-3
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-15…50 °C (without derating); 50…60 °C (with derating factor)
Operating positionVertical +/- 10 degree
Product certificationsUL; TÜV; CSA
MarkingCE
StandardsUL 508C; IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1
Assembly styleEnclosed
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Volume of cooling air240 m3/h
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
Pollution degree2
Ambient air transport temperature-40…70 °C
Ambient air temperature for storage-40…70 °C
Logistical informations
Country of originIN
Main
Range of productAltivar Process ATV900
Product specific applicationProcess for industrial
Product or component typeVariable speed drive
VariantStandard version; With braking chopper
Device applicationIndustrial application
Product destinationAsynchronous motors; Synchronous motors
Network number of phases3 phases
Mounting modeWall mount
Continuous output current78.4 A at 4 kHz for normal duty; 63.4 A at 4 kHz for heavy duty
Communication port protocolEtherNet/IP; Modbus TCP; Modbus serial
[Us] rated supply voltage200...240 V - 15...10 %
Relative symmetric mains voltage tolerance10 %
Relative symmetric network frequency tolerance5 %
nominal output current78.4 A
Motor power kW18.5 kW for normal duty; 15.0 kW for heavy duty
EMC filterIntegrated; With EMC plate option
IP degree of protectionIP21
Degree of protectionUL type 1
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height56.000 cm
Package 1 Width32.000 cm
Package 1 Length82.000 cm
Package 1 Weight37.000 kg
Altivar 900 process frequency converter - converter for moving solid bodies & mechanics e.g. crushers, mixers, extruders, conveyor belts, cranes. Wall mounting. Frequency converter, ATV930, with brake module. Dimensions 226 x 673 x 274 mm, power KW 18.5 kW. Supply voltage, three-phase 200-240 V 50/60 Hz. Output frequency 0.1-500 Hz. Overload in normal operation 120% for 60s, overload in high overload mode 150% for 60s (when downgrading by one power class). Control types asynchronous motors, constant torque, variable torque, optimized torque mode, synchronous motor PM, (permanent magnet) motor. Integrated web server with direct access to system configuration and monitoring, simple master/slave coupling via Ethernet, with load balancing. Application functions for e.g. conveyor belts or cranes. Continuous and historical real-time measurements with customizable dashboards. Integrated safety function STO (Safe Torque Off) SIL3. Number of integrated I/O Analog inputs 2 analog differential inputs, logic inputs 8, relay outputs 3, analog outputs 2. Integrated communication Ethernet-based (with 2 ports, internally switched) Modbus/TCP, Ethernet/IP. Serial communication Modbus RS485 interface. Configuration and control elements Decentralized graphical operator terminal, integrated web server, DTM (Device Type Manager), SoMove software. Optional I/O expansion cards, relay output cards. Optional communication cards (CANopen Daisy Chain RJ45, Sub-D and screw terminals, ProfiNet, Profibus DP V1, EtherCAT and DeviceNet).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1853451
qrcode für Schneider Electric ATV930D18M3 frequency converter 18 kW 200/240 V