| Complementary |
| Electrical connection | Control: screw terminal 0.5...1.5 mm²/20 AWG...16 AWG; Line side: screw terminal 4 x 185 mm²/3 x 350 kcmil; Motor: screw terminal 4 x 185 mm²/3 x 350 kcmil; DC bus: screw terminal 4 x 185 mm²/3 x 350 kcmil |
| Transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
| Exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
| Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
| Type of polarization | No impedance for Modbus serial |
| Number of addresses | 1…247 for Modbus serial |
| Supply | External supply for digital inputs: 24 V DC (19…30 V) |
| Local signalling | Local diagnostic: 3 LED (mono/dual colour); Presence of voltage: 1 LED (red); Embedded communication status: 3 LED (dual colour); Communication module status: 4 LED (dual colour) |
| Input compatibility | DI1...DI8: discrete input level 1 PLC conforming to IEC 61131-2; DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
| Discrete input logic | Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1); Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI8) - discrete input; 5 ms +/- 1 ms (DI7, DI8) - pulse input; 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 5 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Isolation | Between power and control terminals |
| Discrete input number | 10 |
| Discrete input type | DI1...DI8 programmable, 24 V DC ( |
| Discrete output number | 2 |
| Discrete output type | Logic output DQ+ 0…1 kHz |
| Analogue input number | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Physical interface | Ethernet; 2-wire RS 485 |
| Connector type | 2 RJ45; 1 RJ45 |
| Method of access | Slave Modbus TCP |
| Transmission frame | RTU |
| 4 quadrant operation possible | False |
| Asynchronous motor control profile | Variable torque standard; Constant torque standard; Optimized torque mode |
| Synchronous motor control profile | Permanent magnet motor; Synchronous reluctance motor |
| Maximum output frequency | 599 Hz |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01...9999 s |
| Motor slip compensation | Not available in permanent magnet motor law; Automatic whatever the load; Can be suppressed; Adjustable |
| Switching frequency | 1...8 kHz adjustable; 2.5...8 kHz with derating factor |
| Nominal switching frequency | 2.5 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | False |
| Line current | 569.0 A at 380 V (normal duty); 457.0 A at 380 V (heavy duty); 461.0 A at 480 V (normal duty); 375.0 A at 480 V (heavy duty) |
| Maximum input current | 569.0 A |
| Maximum output voltage | 480.0 V |
| Apparent power | 351 kVA at 480 V (normal duty); 286 kVA at 480 V (heavy duty) |
| Maximum transient current | 739 A during 60 s (normal duty); 722 A during 60 s (heavy duty) |
| Network frequency | 50...60 Hz |
| Prospective line Isc | 50 kA |
| Base load current at high overload | 481.0 A |
| Base load current at low overload | 616.0 A |
| Power dissipation in W | Forced convection: 7099 W at 380 V, switching frequency 2.5 kHz; Natural convection: 769 W at 380 V, switching frequency 2.5 kHz |
| With safety function Safely Limited Speed (SLS) | True |
| With safety function Safe brake management (SBC/SBT) | True |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | True |
| With sft fct Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | True |
| With safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Protection type | Thermal protection: motor; Safe torque off: motor; Motor phase break: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive |
| Quantity per set | 1 |
| Width | 598 mm |
| Height | 1195 mm |
| Depth | 380 mm |
| Net weight | 203 kg |
| Contractual warranty |
| Warranty (in months) | 18 |
| Environment |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
| Noise level | 76 dB conforming to 86/188/EEC |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Environmental characteristic | Chemical pollution resistance class 3C2 conforming to IEC 60721-3-3; Dust pollution resistance class 3S2 conforming to IEC 60721-3-3 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…40 °C (without derating); 40…60 °C (with derating factor) |
| Operating position | Vertical +/- 10 degree |
| Product certifications | CSA; UL; TÜV |
| Marking | CE |
| Standards | UL 508C; IEC 61800-3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1 |
| Assembly style | Enclosed |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
| Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Volume of cooling air | 1260 m3/h |
| Overvoltage category | III |
| Regulation loop | Adjustable PID regulator |
| Pollution degree | 2 |
| Ambient air transport temperature | -25…70 °C |
| Ambient air temperature for storage | -25…70 °C |
| Logistical informations |
| Country of origin | CN |
| Main |
| Range of product | Altivar Process ATV900 |
| Product specific application | Process for industrial |
| Product or component type | Variable speed drive |
| Variant | Without braking chopper; Standard version |
| Device application | Industrial application |
| Product destination | Asynchronous motors; Synchronous motors |
| Network number of phases | 3 phases |
| Mounting mode | Wall mount |
| Continuous output current | 616 A at 2.5 kHz for normal duty; 481 A at 2.5 kHz for heavy duty |
| Communication port protocol | EtherNet/IP; Modbus serial; Modbus TCP |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| Relative symmetric mains voltage tolerance | 10 % |
| Relative symmetric network frequency tolerance | 5 % |
| nominal output current | 616.0 A |
| Motor power kW | 315.0 kW for normal duty; 250.0 kW for heavy duty |
| EMC filter | Integrated; With EMC plate option |
| IP degree of protection | IP21 |
| Degree of protection | UL type 1 |
| Packing Units |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 65.000 cm |
| Package 1 Width | 76.000 cm |
| Package 1 Length | 142.000 cm |
| Package 1 Weight | 252.000 kg |
Performance-oriented frequency convertersBy supporting energy management, asset management and also the overall performance of the process, this new frequency converter concept meets the most important process and equipment expectations in terms of efficiency and operating costs of your plant.Sustainable cost savings thanks to predictable maintenance based on conditionReduction of downtime by up to 20% without additional investmentProcess efficiencyThe Altivar Process 900 range focuses on maximum productivity with particularly efficient motor control and connectivity.It offers special functionality for the industrial process segment:Excellent motor performance for any type of motorFull control of all types of couplings in master/slave applicationsNetwork services help ensure uninterrupted operation even in the event of a connection failureWeb server and data acquisition help reduce downtime through fast troubleshooting and preventive maintenanceFull control of your applicationsMaximize the performance of your applications by using drive-to-drive communication: full control of all types of couplings in master/slave applications.Comprehensive management and flexibility of speed and Torque for rigid and flexible couplingsSystem protection functions to increase production and reduce downtimeReal-time informationWeb server and services via EthernetThe web server interface integrated on the basis of an Ethernet network enables you to monitor your processes with your usual work toolsLocal and remote access to energy consumption and user-defined dashboards ensure that you can access your energy consumption 24/7 from anywhere via your PC, tablet or smartphoneCustomized control cabinet solutions according to your requirements (Drive Systems)Minimized design and delivery risksReduces the time required for commissioning and adjustmentExtended specificationsCompact and modular design for harsh environments, ideal for plant extensions, retrofits and new plants.Withstands tough usage regulations, both from an electrical and environmental perspectiveRegenerative drive systemsThe ATV980 regenerative drive systems support increased efficiency by feeding the converter energy back into the power grid:Ready-to-connect solution for converters where generator operating states can occur4-quadrant drive solution with bumpless switching from Motor operation to generator operationCustomizable Braking resistorsBraking resistors allow Altivar Process frequency converters to operate during braking to a standstill by dissipating the braking energy. They enable maximum transient braking torque.Designed for installation outside the enclosure,However, they should not hinder natural cooling. Brake modules offer protection classes IP 20 and IP 23 and thermal protection is provided by an integrated temperature sensor.