Schneider Electric ATV650U75N4E, EAN: 3606485410548

Schneider Electric ATV650U75N4E frequency converter 7,5 kW

Industrial Material > Automation > Frequency converter, soft starter

Schneider Electric ATV650U75N4E frequency converter 7,5 kW

Lieske Part No. 638444
Mfg Part No ATV650U75N4E
EAN-Code 3606485410548
Manufacturer Schneider Electric
Here only 2.051,05 EUR
2.440,75 EUR incl. VAT

Further information for Schneider Electric ATV650U75N4E frequency converter 7,5 kW

Complementary
Discrete input number8
Discrete input typeDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (
Discrete input logic16 preset speeds
Discrete output number0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA; Relay outputs R2A, R2C 30 V DC 5000 mA; Relay outputs R3A, R3C 250 V AC 5000 mA; Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits; AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits; Software-configurable current DQ-, DQ+: 30 V DC; Software-configurable current DQ-, DQ+: 100 mA
Relay output number3
Relay output typeConfigurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Network number of phases3 phases
Physical interfaceEthernet; 2-wire RS 485
Method of accessSlave Modbus TCP
Transmission rate10, 100 Mbits; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frameRTU
Permissible temporary current boost1.5 x In during 60 s (heavy duty); 1.1 x In during 60 s (normal duty)
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
Frequency resolutionAnalog input: 0.012/50 Hz; Display unit: 0.1 Hz
Electrical connectionMotor: screw terminal 6...10 mm²/10 AWG...8 AWG; Line side: screw terminal 4...6 mm²/12 AWG...10 AWG; Control: removable screw terminals 0.5...1.5 mm²
Connector typeRJ45 (on the remote graphic terminal) for Modbus serial; RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses1…247 for Modbus serial
SupplyInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %
Local signalling3 LEDs (dual colour) for embedded communication status; 4 LEDs (dual colour) for communication module status; 1 LED (red) for presence of voltage; 3 LEDs for local diagnostic
Input compatibilityDI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2; DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2
Sampling duration5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AO1) - analog output; 2 ms +/- 0.5 ms (DI1...DI4) - discrete input
Accuracy+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output; +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Linearity errorAO1, AO2: +/- 0.2 % for analog output; AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
IsolationBetween power and control terminals
Power range7…11 kW at 480…500 V 3 phases
Enclosure mountingWall mounted
4 quadrant operation possibleFalse
Asynchronous motor control profileConstant torque standard; Optimized torque mode; Variable torque standard
Synchronous motor control profileSynchronous reluctance motor; Permanent magnet motor
Maximum output frequency500 kHz
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Motor slip compensationAdjustable; Can be suppressed; Not available in permanent magnet motor law; Automatic whatever the load
Switching frequency4...12 kHz with derating factor; 2...12 kHz adjustable
Nominal switching frequency4 kHz
Braking to standstillBy DC injection
Brake chopper integratedFalse
Maximum input current13.8 A
Maximum output voltage480.0 V
Apparent power7.6 kVA at 480 V (heavy duty); 9.9 kVA at 480 V (normal duty)
Maximum transient current19.1 A during 60 s (heavy duty); 18.2 A during 60 s (normal duty)
Network frequency50...60 Hz
Prospective line Isc50 kA
Base load current at high overload12.7 A
Base load current at low overload16.5 A
With safety function Safely Limited Speed (SLS)False
With safety function Safe brake management (SBC/SBT)False
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)False
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)True
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeSafe torque off: motor; Motor phase break: motor; Thermal protection: drive; Safe torque off: drive; Overheating: drive; Overcurrent between output phases and earth: drive; Overload of output voltage: drive; Short-circuit protection: drive; Motor phase break: drive; Overvoltages on the DC bus: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Line supply phase loss: drive; Overspeed: drive; Break on the control circuit: drive; Thermal protection: motor
Quantity per set1
Width264 mm
Height678 mm
Depth330 mm
Net weight13.7 kg
Contractual warranty
Warranty (in months)18
Environment
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level52 dB conforming to 86/188/EEC
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6; 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation40…50 °C (with derating factor); -15…40 °C (without derating)
Operating altitude1000...4800 m with current derating 1 % per 100 m;
Operating positionVertical +/- 10 degree
Product certificationsCSA; DNV-GL; ATEX zone 2/22; ATEX INERIS; UL
MarkingCE
StandardsIEC 61800-3; IEC 61800-3 environment 1 category C2; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1
Electromagnetic compatibilityRadiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
Ambient air transport temperature-40…70 °C
Ambient air temperature for storage-40…70 °C
Logistical informations
Country of originCN
Main
Range of productAltivar Process ATV600
Product specific applicationProcess and utilities
Product or component typeVariable speed drive
VariantWith disconnect switch
Device short nameATV650
Mounting modeWall mount
Communication port protocolEthernet; Modbus TCP
[Us] rated supply voltage380...480 V - 15...10 %
Relative symmetric mains voltage tolerance10 %
Relative symmetric network frequency tolerance5 %
nominal output current16.5 A
IP degree of protectionIP55
Product destinationAsynchronous motors; Synchronous motors
EMC filterIntegrated with 50 m conforming to IEC 61800-3 category C2; Integrated with 150 m conforming to IEC 61800-3 category C3
Type of coolingForced convection
Supply frequency50...60 Hz - 5...5 %
Motor power kW5.5 kW (heavy duty); 7.5 kW (normal duty)
Motor power hp7.5 hp heavy duty; 10 hp normal duty
Line current11.9 A at 480 V (normal duty); 10.5 A at 380 V (heavy duty); 9.2 A at 480 V (heavy duty); 13.8 A at 380 V (normal duty)
Continuous output current12.7 A at 4 kHz for heavy duty; 16.5 A at 4 kHz for normal duty
Speed drive output frequency0.1…500 Hz
Safety functionSTO (safe torque off) SIL 3
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height54.000 cm
Package 1 Width40.000 cm
Package 1 Length80.000 cm
Package 1 Weight30.000 kg
IP55 with Vario load break switch. ATV650 frequency converter, 10 HP, with main switch. Dimensions 264 x 678 x 330 mm, power KW 7.5 kW. Output frequency 0.1-500 Hz. Overload in normal operation 110% for 60s, overload in high overload mode 150% for 60s (when downgrading by one power class). Control types Asynchronous motors, constant torque, variable torque, optimized torque mode, synchronous motor PM, (permanent magnet) motor. Integrated safety function STO (Safe Torque Off) SIL3. Number of integrated I/O Analog inputs 3. Analog outputs 2. Digital inputs 8. Relay outputs 3. Integrated communication Modbus/TCP, serial Modbus interface. Configuration and control elements Decentralized graphical operator terminal, integrated web server, DTM (Device Type Manager), SoMove software. Optional I/O expansion cards, relay output cards. Optional communication cards (EtherNet/IP and Modbus/TCP with two ports, CANopen Daisy Chain RJ45, Sub-D and screw terminals, ProfiNet, Profibus DP V1 and DeviceNet).
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter: